Optimization of design parameters and operation conditions of solar-air source heat pump coupled system for rural buildings in cold and severe cold regions

IF 6 2区 工程技术 Q2 ENERGY & FUELS
Zhibin Zhang , Ying Cao , Siyu Qin , Zheng Wang , Wei Gao , Guosheng Jia , Linwen Jin
{"title":"Optimization of design parameters and operation conditions of solar-air source heat pump coupled system for rural buildings in cold and severe cold regions","authors":"Zhibin Zhang ,&nbsp;Ying Cao ,&nbsp;Siyu Qin ,&nbsp;Zheng Wang ,&nbsp;Wei Gao ,&nbsp;Guosheng Jia ,&nbsp;Linwen Jin","doi":"10.1016/j.solener.2024.113147","DOIUrl":null,"url":null,"abstract":"<div><div>Integrating solar energy utilization into air source heat pump heating systems can effectively cut down on energy consumption. However, the complexity of coupled systems poses a challenge to system performance optimization. In this paper, a solar-air source heat pump coupled system designed for heating in cold (Beijing) and severe cold (Changchun) regions is developed and analyzed by TRNSYS software. Response surface methodology (RSM) is employed to establish regression models for different performance indicators, and then the non-dominated sorting genetic algorithm-II (NSGA-II) is adopted to solve the multi-objective optimization of interactive performance parameters through Pareto optimal solution set. The regression models of the performance indicators, i.e., the energy consumption (<em>P</em>), the solar energy assurance rate (<em>Ar</em>) and the ratio of heating supply from solar energy storage tank to building load (<em>Hs</em>), are found to be closely related to the area of solar collectors (<em>A</em>) and the volumes of storage tanks (<em>V<sub>l</sub></em> for solar collector loop and <em>V<sub>s</sub></em> for ASHP loop). The obtained Pareto set successfully balances the optimal values of interactive performance indicators. In cold regions, <em>P</em>, <em>Ar</em>, <em>Hs</em> of the coupled system can be improved respectively by 31.79%, 33.00% and 40.07% compared to the single air source heat pump system. While in severe cold regions, these improvements are 16.25%, 15.35% and 28.38%, respectively. The design method and optimization procedure of this study provide a basis for the optimization of the solar and auxiliary heat source coupled heating systems.</div></div>","PeriodicalId":428,"journal":{"name":"Solar Energy","volume":"286 ","pages":"Article 113147"},"PeriodicalIF":6.0000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Solar Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0038092X24008429","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Integrating solar energy utilization into air source heat pump heating systems can effectively cut down on energy consumption. However, the complexity of coupled systems poses a challenge to system performance optimization. In this paper, a solar-air source heat pump coupled system designed for heating in cold (Beijing) and severe cold (Changchun) regions is developed and analyzed by TRNSYS software. Response surface methodology (RSM) is employed to establish regression models for different performance indicators, and then the non-dominated sorting genetic algorithm-II (NSGA-II) is adopted to solve the multi-objective optimization of interactive performance parameters through Pareto optimal solution set. The regression models of the performance indicators, i.e., the energy consumption (P), the solar energy assurance rate (Ar) and the ratio of heating supply from solar energy storage tank to building load (Hs), are found to be closely related to the area of solar collectors (A) and the volumes of storage tanks (Vl for solar collector loop and Vs for ASHP loop). The obtained Pareto set successfully balances the optimal values of interactive performance indicators. In cold regions, P, Ar, Hs of the coupled system can be improved respectively by 31.79%, 33.00% and 40.07% compared to the single air source heat pump system. While in severe cold regions, these improvements are 16.25%, 15.35% and 28.38%, respectively. The design method and optimization procedure of this study provide a basis for the optimization of the solar and auxiliary heat source coupled heating systems.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Solar Energy
Solar Energy 工程技术-能源与燃料
CiteScore
13.90
自引率
9.00%
发文量
0
审稿时长
47 days
期刊介绍: Solar Energy welcomes manuscripts presenting information not previously published in journals on any aspect of solar energy research, development, application, measurement or policy. The term "solar energy" in this context includes the indirect uses such as wind energy and biomass
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信