[Evaluation of the CellaVision® DM-1200 system for detecting and quantifying schistocytes].

Sami Zouitina, Frédérique Dubois-Galopin
{"title":"[Evaluation of the CellaVision® DM-1200 system for detecting and quantifying schistocytes].","authors":"Sami Zouitina, Frédérique Dubois-Galopin","doi":"10.1684/abc.2024.1921","DOIUrl":null,"url":null,"abstract":"<p><p>Detection of schistocytes is an important first step in the differential diagnosis of thrombotic microangiopathy. It is however labor intensive and prone to subjectivity. To improve and standardize the detection and quantification of schistocytes, we studied its automated analysis by digital microscopy DM1200 (CellaVision®) on 63 positive and 102 negative smears obtained from SP-50 (Sysmex®). Easy to use and very useful for staff training, it showed a lower between-observer coefficient of variation than usually described for manual counting (25% vs. 50%). Very sensitive (100%) in pre-classification, the detection of schistocytes was highly sensitive (98.4%) and specific (96.8%) after reclassification (AUCROC = 0.9929), showing a good correlation with manual microscopy. TAT was comparable to manual counting. For positive smears, the percentage of schistocytes was similar between pre- and post-classification. However, 29.6% of pre-classified schistocytes were removed and 21.8% were added. For negative smears a significative overestimation of schistocytes (292%) was observed. Except poikilocytosis, on negative smears, the most common error of the software (24.9%) was due to platelets classified in schistocytes. Were also observed for example erroneous divisions of the image (3.2%) or artifactual schistocytes resulting from scratches in the smear (2.6%). Another limit is the high number of red blood cells not analyzed (46.8% for high-density smears), which might false the schistocytes percentage. To conclude, CellaVision® technology showed many benefits, but also limits that the operator needs to know.</p>","PeriodicalId":93870,"journal":{"name":"Annales de biologie clinique","volume":"82 5","pages":"579-588"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de biologie clinique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1684/abc.2024.1921","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Detection of schistocytes is an important first step in the differential diagnosis of thrombotic microangiopathy. It is however labor intensive and prone to subjectivity. To improve and standardize the detection and quantification of schistocytes, we studied its automated analysis by digital microscopy DM1200 (CellaVision®) on 63 positive and 102 negative smears obtained from SP-50 (Sysmex®). Easy to use and very useful for staff training, it showed a lower between-observer coefficient of variation than usually described for manual counting (25% vs. 50%). Very sensitive (100%) in pre-classification, the detection of schistocytes was highly sensitive (98.4%) and specific (96.8%) after reclassification (AUCROC = 0.9929), showing a good correlation with manual microscopy. TAT was comparable to manual counting. For positive smears, the percentage of schistocytes was similar between pre- and post-classification. However, 29.6% of pre-classified schistocytes were removed and 21.8% were added. For negative smears a significative overestimation of schistocytes (292%) was observed. Except poikilocytosis, on negative smears, the most common error of the software (24.9%) was due to platelets classified in schistocytes. Were also observed for example erroneous divisions of the image (3.2%) or artifactual schistocytes resulting from scratches in the smear (2.6%). Another limit is the high number of red blood cells not analyzed (46.8% for high-density smears), which might false the schistocytes percentage. To conclude, CellaVision® technology showed many benefits, but also limits that the operator needs to know.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信