Serial VerifyNow P2Y12 platelet reactivity units in cerebral aneurysm patients treated with ticagrelor surrounding stent-coiling or flow diversion.

IF 1.3 Q4 NEUROIMAGING
Tyler M Bielinski, Prateeka Koul, Malie K Collins, Oded Goren, Gregory M Weiner, Christoph J Griessenauer, Clemens M Schirmer, Philipp Hendrix
{"title":"Serial VerifyNow P2Y12 platelet reactivity units in cerebral aneurysm patients treated with ticagrelor surrounding stent-coiling or flow diversion.","authors":"Tyler M Bielinski, Prateeka Koul, Malie K Collins, Oded Goren, Gregory M Weiner, Christoph J Griessenauer, Clemens M Schirmer, Philipp Hendrix","doi":"10.1177/19714009241303127","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Platelet function testing using serial VerifyNow P2Y12 platelet reactivity units (PRUs) is established for guiding clopidogrel antiplatelet therapy in cerebral aneurysm stenting procedures. However, for ticagrelor, the impact of serial PRU testing and the identification of safe PRU ranges remains unexplored.</p><p><strong>Methods: </strong>Flow diversion stenting (<i>n</i> = 232) and stent-assisted coiling procedures (<i>n</i> = 83) performed 05/2017-12/2021 were reviewed. Out of these, 31 flow diversion and 18 stent-coiling procedures were performed on 44 patients using ticagrelor. Baseline demographics, ticagrelor PRUs, and clinical outcomes were assessed.</p><p><strong>Results: </strong>Collectively, 257 ticagrelor P2Y12 PRUs were obtained. PRUs were <100 in 192/257 (74.7%) tests. Only 11/257 (4.3%) PRUs were >200. The overall median ticagrelor PRU was 38 (IQR 11-101). Among the 49 procedures, median PRUs before the procedure (25, IQR 10-67), on the day of the procedure (68, IQR 44-117), and on the day after the procedure (37, IQR 21-79) did not show the significant differences between the groups. A total of seven thromboembolic complications occurred. Median PRUs surrounding the thromboembolic complications (median 182, IQR 148-235) were significantly higher than preprocedural (<i>p</i> < .001), day of surgery (<i>p</i> < .01), and postprocedural PRUs (<i>p</i> < .01). All seven procedures harbored demographic, anatomic, or procedural features increasing the risk for thromboembolic complications.</p><p><strong>Discussion: </strong>The majority of periprocedural ticagrelor PRUs were <100. PRUs at the time point of thromboembolic complications were >120. Despite procedure-complicating features in each thromboembolic case, it raises the question whether safe ticagrelor PRU levels might be lower than those commonly applied for clopidogrel.</p>","PeriodicalId":47358,"journal":{"name":"Neuroradiology Journal","volume":" ","pages":"19714009241303127"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neuroradiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19714009241303127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Platelet function testing using serial VerifyNow P2Y12 platelet reactivity units (PRUs) is established for guiding clopidogrel antiplatelet therapy in cerebral aneurysm stenting procedures. However, for ticagrelor, the impact of serial PRU testing and the identification of safe PRU ranges remains unexplored.

Methods: Flow diversion stenting (n = 232) and stent-assisted coiling procedures (n = 83) performed 05/2017-12/2021 were reviewed. Out of these, 31 flow diversion and 18 stent-coiling procedures were performed on 44 patients using ticagrelor. Baseline demographics, ticagrelor PRUs, and clinical outcomes were assessed.

Results: Collectively, 257 ticagrelor P2Y12 PRUs were obtained. PRUs were <100 in 192/257 (74.7%) tests. Only 11/257 (4.3%) PRUs were >200. The overall median ticagrelor PRU was 38 (IQR 11-101). Among the 49 procedures, median PRUs before the procedure (25, IQR 10-67), on the day of the procedure (68, IQR 44-117), and on the day after the procedure (37, IQR 21-79) did not show the significant differences between the groups. A total of seven thromboembolic complications occurred. Median PRUs surrounding the thromboembolic complications (median 182, IQR 148-235) were significantly higher than preprocedural (p < .001), day of surgery (p < .01), and postprocedural PRUs (p < .01). All seven procedures harbored demographic, anatomic, or procedural features increasing the risk for thromboembolic complications.

Discussion: The majority of periprocedural ticagrelor PRUs were <100. PRUs at the time point of thromboembolic complications were >120. Despite procedure-complicating features in each thromboembolic case, it raises the question whether safe ticagrelor PRU levels might be lower than those commonly applied for clopidogrel.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Neuroradiology Journal
Neuroradiology Journal NEUROIMAGING-
CiteScore
2.50
自引率
0.00%
发文量
101
期刊介绍: NRJ - The Neuroradiology Journal (formerly Rivista di Neuroradiologia) is the official journal of the Italian Association of Neuroradiology and of the several Scientific Societies from all over the world. Founded in 1988 as Rivista di Neuroradiologia, of June 2006 evolved in NRJ - The Neuroradiology Journal. It is published bimonthly.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信