Correlation between right atrial pressure measured via right heart catheterization and venous excess ultrasound, inferior vena cava diameter, and ultrasound-measured jugular venous pressure: a prospective observational study.

IF 3.4 Q2 Medicine
Suppawee Klangthamneam, Krissada Meemook, Tananchai Petnak, Anchana Sonkaew, Taweevat Assavapokee
{"title":"Correlation between right atrial pressure measured via right heart catheterization and venous excess ultrasound, inferior vena cava diameter, and ultrasound-measured jugular venous pressure: a prospective observational study.","authors":"Suppawee Klangthamneam, Krissada Meemook, Tananchai Petnak, Anchana Sonkaew, Taweevat Assavapokee","doi":"10.1186/s13089-024-00397-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Venous congestion is associated with adverse cardiovascular outcomes, necessitating accurate venous pressure assessment. Current methods, such as right heart catheterization (RHC), have limitations. Non-invasive techniques, including venous excess ultrasound (VExUS), inferior vena cava (IVC) assessment, and ultrasound-measured jugular venous pressure (uJVP), show promise but require validation in diverse populations.</p><p><strong>Aims: </strong>We aimed to assess the correlation between right atrial pressure (RAP) via RHC and non-invasive methods, including VExUS, IVC diameter with collapsibility index (CI) by American Society of Echocardiography (ASE) classification, and uJVP.</p><p><strong>Methods: </strong>In a prospective study involving 73 patients undergoing RHC, we evaluated the correlation between RAP and VExUS, IVC CI by ASE classification, and uJVP. We introduced and compared a modified VExUS grading system.</p><p><strong>Results: </strong>VExUS significantly correlated with RAP (p < 0.001), especially between VExUS grade 0 and grade 3. RAP significantly differed across IVC classifications by ASE (P < 0.001). VExUS grade 0 correlated with IVC class 1, and VExUS grade 3 correlated with IVC class 3. The modified VExUS grading system improved low and high RAP differentiation. uJVP exhibited a robust, highly significant positive correlation with invasively measured RAP (ρ = 0.67, P < 0.001).</p><p><strong>Conclusion: </strong>This study establishes a strong correlation between non-invasive ultrasound measurements (VExUS, IVC diameter with CI, and uJVP) and invasively measured RAP. These findings underscore the clinical potential of these non-invasive techniques in venous congestion assessment and patient risk stratification.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":"16 1","pages":"50"},"PeriodicalIF":3.4000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-024-00397-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Venous congestion is associated with adverse cardiovascular outcomes, necessitating accurate venous pressure assessment. Current methods, such as right heart catheterization (RHC), have limitations. Non-invasive techniques, including venous excess ultrasound (VExUS), inferior vena cava (IVC) assessment, and ultrasound-measured jugular venous pressure (uJVP), show promise but require validation in diverse populations.

Aims: We aimed to assess the correlation between right atrial pressure (RAP) via RHC and non-invasive methods, including VExUS, IVC diameter with collapsibility index (CI) by American Society of Echocardiography (ASE) classification, and uJVP.

Methods: In a prospective study involving 73 patients undergoing RHC, we evaluated the correlation between RAP and VExUS, IVC CI by ASE classification, and uJVP. We introduced and compared a modified VExUS grading system.

Results: VExUS significantly correlated with RAP (p < 0.001), especially between VExUS grade 0 and grade 3. RAP significantly differed across IVC classifications by ASE (P < 0.001). VExUS grade 0 correlated with IVC class 1, and VExUS grade 3 correlated with IVC class 3. The modified VExUS grading system improved low and high RAP differentiation. uJVP exhibited a robust, highly significant positive correlation with invasively measured RAP (ρ = 0.67, P < 0.001).

Conclusion: This study establishes a strong correlation between non-invasive ultrasound measurements (VExUS, IVC diameter with CI, and uJVP) and invasively measured RAP. These findings underscore the clinical potential of these non-invasive techniques in venous congestion assessment and patient risk stratification.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信