{"title":"Diagnostic accuracy of strain cervical elastography as a predictor for preterm delivery: A single tertiary care centre study.","authors":"Abhinash Sharma, Shruti Thakur, Ashwani Tomar, Rita Mittal, Mukesh Surya","doi":"10.1177/1742271X241277448","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Preterm delivery is a grave and demanding problem that accounts for the major cause of neonatal deaths and long-term morbidities. It remains an unresolved health issue of global dimensions. Cervical elastography is evolving as a useful diagnostic tool for its timely prediction so that individualised management can be done.</p><p><strong>Aim: </strong>To assess the diagnostic accuracy of transvaginal strain cervical elastography in prediction of preterm delivery.</p><p><strong>Methods: </strong>This prospective observational study was conducted from June 2021 to August 2022 in a tertiary care institute of North India. A total of 75 low-risk asymptomatic women were included. Transvaginal ultrasound was performed for the cervical length in the second and third trimesters. In addition, we collected strain elastography data such as colour codes from six regions of the cervix, that is, at the anterior and posterior lips of internal os, middle one-third of the cervix and the external os, and the strain ratios from these three cervical levels were also calculated. Then these parameters were compared with cervical length, second and third trimester groups and also with preterm and term delivery groups.</p><p><strong>Result: </strong>The red colour (soft colour) at the anterior lip of internal os was the best predictor of preterm delivery in our study with a sensitivity and specificity of 63.64% and 96.87%, respectively. The elastography strain ratio of >2 at the internal os and cervical length ⩽2.8 cm were the additional predictors for the same.</p><p><strong>Conclusion: </strong>Cervical elastography can serve as a potential and reliable predictor for preterm delivery.</p>","PeriodicalId":23440,"journal":{"name":"Ultrasound","volume":" ","pages":"1742271X241277448"},"PeriodicalIF":0.8000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11600413/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1742271X241277448","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Preterm delivery is a grave and demanding problem that accounts for the major cause of neonatal deaths and long-term morbidities. It remains an unresolved health issue of global dimensions. Cervical elastography is evolving as a useful diagnostic tool for its timely prediction so that individualised management can be done.

Aim: To assess the diagnostic accuracy of transvaginal strain cervical elastography in prediction of preterm delivery.

Methods: This prospective observational study was conducted from June 2021 to August 2022 in a tertiary care institute of North India. A total of 75 low-risk asymptomatic women were included. Transvaginal ultrasound was performed for the cervical length in the second and third trimesters. In addition, we collected strain elastography data such as colour codes from six regions of the cervix, that is, at the anterior and posterior lips of internal os, middle one-third of the cervix and the external os, and the strain ratios from these three cervical levels were also calculated. Then these parameters were compared with cervical length, second and third trimester groups and also with preterm and term delivery groups.

Result: The red colour (soft colour) at the anterior lip of internal os was the best predictor of preterm delivery in our study with a sensitivity and specificity of 63.64% and 96.87%, respectively. The elastography strain ratio of >2 at the internal os and cervical length ⩽2.8 cm were the additional predictors for the same.

Conclusion: Cervical elastography can serve as a potential and reliable predictor for preterm delivery.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound
Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.70
自引率
0.00%
发文量
55
期刊介绍: Ultrasound is the official journal of the British Medical Ultrasound Society (BMUS), a multidisciplinary, charitable society comprising radiologists, obstetricians, sonographers, physicists and veterinarians amongst others.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信