Sander C Kuipers, Jérémy Godart, Eva M Negenman, Anouk Corbeau, András G Zolnay, Heloisa H Deuzeman, Stephanie M de Boer, Remi A Nout, Mischa S Hoogeman
{"title":"Margin and robustness settings for a library-of-plans IMPT strategy for locally advanced cervical cancer.","authors":"Sander C Kuipers, Jérémy Godart, Eva M Negenman, Anouk Corbeau, András G Zolnay, Heloisa H Deuzeman, Stephanie M de Boer, Remi A Nout, Mischa S Hoogeman","doi":"10.1088/1361-6560/ad9882","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT).<i>Approach.</i>We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach. Six different robustness settings (2-7 mm set-up robustness (SR) plus 3% range robustness (RR)) were used to create those 120 IMPT plans. Each fraction was simulated with a weekly reCT, combined with the sampling of inter- and intrafraction treatment uncertainties. The fraction doses were accumulated to obtain a treatment dose to the target volumes, distinguishing between the low-risk clinical target volume (CTV-T-LR) and the elective CTV (CTV-E). If one of the two targets obtained an adequate coverage for more than 90% of the treatments, different anisotropic margins were sampled on top of the robustness setting to the other target to obtain the Pareto-optimal margin in terms of adequate coverage versus increase in target volume.<i>Main results.</i>The percentage of treatments that reach the dose criterion<i>V</i><sub>42.75Gy</sub>> 95% for the CTV-T-LR was 22.3%, 28.5%, 51.2%, 73.1%, 85.3%, and 90.0% for 2, 3, 4, 5, 6, and 7 mm SR plus 3% RR and for the CTV-E, this percentage was 60.4%, 73.8%, 86.5%, 92.3%, 96.9%, and 98.5%. The Pareto-optimal margin combined with a 5 mm/3% robustness setting for the CTV-T-LR with an adequate coverage for >90% of the treatments was given by {0, 1, 0, 3, 3, 0} mm in the left, right, anterior, posterior, cranial, caudal direction.<i>Significance.</i>Our study evaluated combinations of robustness and anisotropic margin settings for IMPT for LACC. With 5 mm SR and 3% RR for CTV-E and CTV-T-LR plus a margin to the CTV-T-LR of {0, 1, 0, 3, 3, 0} mm in left, right, anterior, posterior, cranial, and caudal ensured an adequate coverage for >90% of the simulated IMPT treatments.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ad9882","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT).Approach.We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach. Six different robustness settings (2-7 mm set-up robustness (SR) plus 3% range robustness (RR)) were used to create those 120 IMPT plans. Each fraction was simulated with a weekly reCT, combined with the sampling of inter- and intrafraction treatment uncertainties. The fraction doses were accumulated to obtain a treatment dose to the target volumes, distinguishing between the low-risk clinical target volume (CTV-T-LR) and the elective CTV (CTV-E). If one of the two targets obtained an adequate coverage for more than 90% of the treatments, different anisotropic margins were sampled on top of the robustness setting to the other target to obtain the Pareto-optimal margin in terms of adequate coverage versus increase in target volume.Main results.The percentage of treatments that reach the dose criterionV42.75Gy> 95% for the CTV-T-LR was 22.3%, 28.5%, 51.2%, 73.1%, 85.3%, and 90.0% for 2, 3, 4, 5, 6, and 7 mm SR plus 3% RR and for the CTV-E, this percentage was 60.4%, 73.8%, 86.5%, 92.3%, 96.9%, and 98.5%. The Pareto-optimal margin combined with a 5 mm/3% robustness setting for the CTV-T-LR with an adequate coverage for >90% of the treatments was given by {0, 1, 0, 3, 3, 0} mm in the left, right, anterior, posterior, cranial, caudal direction.Significance.Our study evaluated combinations of robustness and anisotropic margin settings for IMPT for LACC. With 5 mm SR and 3% RR for CTV-E and CTV-T-LR plus a margin to the CTV-T-LR of {0, 1, 0, 3, 3, 0} mm in left, right, anterior, posterior, cranial, and caudal ensured an adequate coverage for >90% of the simulated IMPT treatments.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry