{"title":"Inspection and maintenance of a system with a bypass component","authors":"M.D. Berrade , E. Calvo , F.G. Badía","doi":"10.1016/j.ress.2024.110649","DOIUrl":null,"url":null,"abstract":"<div><div>We present an inspection and maintenance model for a two-component lubrication system, filter and bypass valve, with applications to centralized lubrication systems. It presents significant differences from redundant systems in previous studies on cold, warm or hot stand-by components. These are the dissimilarity between the filter and the bypass, as the latter can induce catastrophic damage after a long working period, and the stochastic dependence between the filter and the bypass valve. Inspection and testing is focused on the valve, and only if it fails to open on inspection, or it is found to be open, is the filter inspection triggered. Preventive maintenance is mainly concerned with the filter, which is replaced periodically and also when an inspection detects an open valve or a clogged filter. The sensitivity analysis reveals that the optimum policy depends more on the parameters defining the lifetime of the filter than on those of the valve.</div></div>","PeriodicalId":54500,"journal":{"name":"Reliability Engineering & System Safety","volume":"255 ","pages":"Article 110649"},"PeriodicalIF":9.4000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reliability Engineering & System Safety","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0951832024007208","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, INDUSTRIAL","Score":null,"Total":0}
引用次数: 0
Abstract
We present an inspection and maintenance model for a two-component lubrication system, filter and bypass valve, with applications to centralized lubrication systems. It presents significant differences from redundant systems in previous studies on cold, warm or hot stand-by components. These are the dissimilarity between the filter and the bypass, as the latter can induce catastrophic damage after a long working period, and the stochastic dependence between the filter and the bypass valve. Inspection and testing is focused on the valve, and only if it fails to open on inspection, or it is found to be open, is the filter inspection triggered. Preventive maintenance is mainly concerned with the filter, which is replaced periodically and also when an inspection detects an open valve or a clogged filter. The sensitivity analysis reveals that the optimum policy depends more on the parameters defining the lifetime of the filter than on those of the valve.
期刊介绍:
Elsevier publishes Reliability Engineering & System Safety in association with the European Safety and Reliability Association and the Safety Engineering and Risk Analysis Division. The international journal is devoted to developing and applying methods to enhance the safety and reliability of complex technological systems, like nuclear power plants, chemical plants, hazardous waste facilities, space systems, offshore and maritime systems, transportation systems, constructed infrastructure, and manufacturing plants. The journal normally publishes only articles that involve the analysis of substantive problems related to the reliability of complex systems or present techniques and/or theoretical results that have a discernable relationship to the solution of such problems. An important aim is to balance academic material and practical applications.