A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples.

IF 4.9 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL
Michelle T Tran, Sophia V Gomez, Vera Alenicheva, Vincent T Remcho
{"title":"A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples.","authors":"Michelle T Tran, Sophia V Gomez, Vera Alenicheva, Vincent T Remcho","doi":"10.3390/bios14110559","DOIUrl":null,"url":null,"abstract":"<p><p>Determining the total antioxidant capacity (TAC) of biological samples is a valuable approach to measuring health status under oxidative stress conditions, such as infertility and type 2 diabetes. The Trolox equivalent antioxidant capacity (TEAC) assay is the most common approach to evaluating TAC in biological matrices. This assay is typically performed in clinical settings on a microtiter plate using a plate reader. However, the instrumentation and expertise requirements, and the resulting delay in the reporting of assay outcomes, make solution-based TEAC assays impractical for point-of-care or at-home testing, where individuals may want to monitor their health status during treatment. This work introduces the first microfluidic paper-based analytical device (µPAD) that measures TAC in human serum using TEAC assay chemistry. TAC was determined through a colorimetric image analysis of the degree of decolorization of 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) radical cations (ABTS<sup>●+</sup>) by serum antioxidants. The µPAD showed a linear response to Trolox, ranging from 0.44 to 2.4 mM, (r  =  0.999). The performance of paper-based TEAC assays was validated through direct comparison to solution-based TEAC assays. There was a 0.04 mM difference in TAC values between the two platforms, well within one standard deviation of a standard solution-based assay conducted on an aliquot of the same serum sample (±0.25 mM). The µPAD had a limit of detection (LOD) of 0.20 mM, well below the TAC of normal human serum. The results suggest that the proposed device can be used for biological TAC determination and expands the field of TAC analysis in point-of-care health monitoring.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"14 11","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11591649/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios14110559","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Determining the total antioxidant capacity (TAC) of biological samples is a valuable approach to measuring health status under oxidative stress conditions, such as infertility and type 2 diabetes. The Trolox equivalent antioxidant capacity (TEAC) assay is the most common approach to evaluating TAC in biological matrices. This assay is typically performed in clinical settings on a microtiter plate using a plate reader. However, the instrumentation and expertise requirements, and the resulting delay in the reporting of assay outcomes, make solution-based TEAC assays impractical for point-of-care or at-home testing, where individuals may want to monitor their health status during treatment. This work introduces the first microfluidic paper-based analytical device (µPAD) that measures TAC in human serum using TEAC assay chemistry. TAC was determined through a colorimetric image analysis of the degree of decolorization of 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) radical cations (ABTS●+) by serum antioxidants. The µPAD showed a linear response to Trolox, ranging from 0.44 to 2.4 mM, (r  =  0.999). The performance of paper-based TEAC assays was validated through direct comparison to solution-based TEAC assays. There was a 0.04 mM difference in TAC values between the two platforms, well within one standard deviation of a standard solution-based assay conducted on an aliquot of the same serum sample (±0.25 mM). The µPAD had a limit of detection (LOD) of 0.20 mM, well below the TAC of normal human serum. The results suggest that the proposed device can be used for biological TAC determination and expands the field of TAC analysis in point-of-care health monitoring.

测定人体血清样本总抗氧化能力的纸基测定法
测定生物样本的总抗氧化能力(TAC)是衡量氧化应激条件下健康状况(如不孕症和 2 型糖尿病)的重要方法。三氧化碳当量抗氧化能力(TEAC)测定是评估生物基质中总抗氧化能力的最常用方法。临床上通常使用平板阅读器在微孔板上进行该检测。然而,由于对仪器和专业知识的要求,以及由此导致的检测结果报告延迟,基于溶液的 TEAC 检测法不适于在治疗过程中监测个人健康状况的护理点或家庭检测。这项研究首次推出了基于微流控纸的分析装置(µPAD),利用 TEAC 分析化学方法测量人体血清中的 TAC。TAC是通过对血清抗氧化剂对2,2'-偶氮双(3-乙基苯并噻唑啉-6-磺酸)自由基阳离子(ABTS●+)的脱色程度进行比色图像分析来测定的。µPAD 与 Trolox 呈线性响应,范围在 0.44 至 2.4 mM 之间(r = 0.999)。通过与基于溶液的 TEAC 检测法直接比较,验证了基于纸张的 TEAC 检测法的性能。两个平台的 TAC 值相差 0.04 毫摩尔,远低于对同一血清样本等分进行的标准溶液检测的一个标准偏差(±0.25 毫摩尔)。µPAD 的检测限 (LOD) 为 0.20 mM,远低于正常人体血清的 TAC 值。结果表明,所提出的装置可用于生物 TAC 测定,并拓展了在护理点健康监测中进行 TAC 分析的领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信