Assessing the Knee Extensor's Rate of Force Development Using a Fixed Handheld Dynamometer: An Inter- and Intrasession Reliability Study.

IF 1.3 4区 医学 Q3 REHABILITATION
Tomer Yona, Arielle G Fischer
{"title":"Assessing the Knee Extensor's Rate of Force Development Using a Fixed Handheld Dynamometer: An Inter- and Intrasession Reliability Study.","authors":"Tomer Yona, Arielle G Fischer","doi":"10.1123/jsr.2024-0185","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>The rate of force development (RFD), defined as the ability to rapidly generate muscle force, is commonly tested using an electromechanical dynamometer in isometric mode. However, these devices are expensive and not readily available. Therefore, this study aims to evaluate the interrater reliability of a fixed handheld dynamometer to measure the knee extensors' RFD and provide reference values using the proposed method.</p><p><strong>Design: </strong>This study used a cross-sectional study design.</p><p><strong>Methods: </strong>Using a fixed handheld dynamometer (microFET2) and a 3-dimensional-printed adapter, we evaluated the knee extensor muscles  in participants seated at the edge of a treatment bed. Each participant performed a standardized warm-up, followed by 3 maximal isometric knee extension trials. The outcome measures were peak force and early and late phase RFD (0-100 and 0-200 ms, respectively). The study consisted of 3 sessions: Visit one comprised of an initial session (session 1A) followed by a second session (session 1B) after 30 minutes for intrasession reliability; and visit two, conducted on week later, comprised the third session (session 2) for intersession reliability.</p><p><strong>Results: </strong>Fifty-one participants were enrolled in the study. The in-session intraclass correlation coefficient for the early phase RFD was .87 (95% CI, .74-.92) and .91 to .92 (95% CI, .87-.94) for the late phase. The between-session intraclass correlation coefficient for the early phase RFD was .83 to .86 (95% CI, .74-.91) and .87 to .90 (95% CI, .80-.94) for the late phase. Finally, the peak force's intraclass correlation coefficient was .95 (95% CI, .92-.97) for the in-session and .91 to .92 (95% CI, .86-.95) for the between-session reliability.</p><p><strong>Conclusions: </strong>Our approach provides a reliable, cost-effective, and quick method to evaluate the knee extensor muscles' RFD and peak force.</p>","PeriodicalId":50041,"journal":{"name":"Journal of Sport Rehabilitation","volume":" ","pages":"1-6"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sport Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1123/jsr.2024-0185","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Context: The rate of force development (RFD), defined as the ability to rapidly generate muscle force, is commonly tested using an electromechanical dynamometer in isometric mode. However, these devices are expensive and not readily available. Therefore, this study aims to evaluate the interrater reliability of a fixed handheld dynamometer to measure the knee extensors' RFD and provide reference values using the proposed method.

Design: This study used a cross-sectional study design.

Methods: Using a fixed handheld dynamometer (microFET2) and a 3-dimensional-printed adapter, we evaluated the knee extensor muscles  in participants seated at the edge of a treatment bed. Each participant performed a standardized warm-up, followed by 3 maximal isometric knee extension trials. The outcome measures were peak force and early and late phase RFD (0-100 and 0-200 ms, respectively). The study consisted of 3 sessions: Visit one comprised of an initial session (session 1A) followed by a second session (session 1B) after 30 minutes for intrasession reliability; and visit two, conducted on week later, comprised the third session (session 2) for intersession reliability.

Results: Fifty-one participants were enrolled in the study. The in-session intraclass correlation coefficient for the early phase RFD was .87 (95% CI, .74-.92) and .91 to .92 (95% CI, .87-.94) for the late phase. The between-session intraclass correlation coefficient for the early phase RFD was .83 to .86 (95% CI, .74-.91) and .87 to .90 (95% CI, .80-.94) for the late phase. Finally, the peak force's intraclass correlation coefficient was .95 (95% CI, .92-.97) for the in-session and .91 to .92 (95% CI, .86-.95) for the between-session reliability.

Conclusions: Our approach provides a reliable, cost-effective, and quick method to evaluate the knee extensor muscles' RFD and peak force.

使用固定式手持测力计评估膝关节伸肌的力量发展速度:训练间和训练内可靠性研究
背景:力量发展速率(RFD)是指快速产生肌肉力量的能力,通常使用等长模式下的机电测力计进行测试。然而,这些设备价格昂贵且不易获得。因此,本研究旨在评估使用固定手持式测力计测量膝关节伸肌RFD的互测可靠性,并使用建议的方法提供参考值:本研究采用横断面研究设计:使用固定式手持测力计(microFET2)和三维打印适配器,我们对坐在治疗床边的参与者的膝关节伸肌进行了评估。每位参与者先进行标准化热身,然后进行 3 次最大等长伸膝试验。结果测量为峰值力、早期和晚期 RFD(分别为 0-100 毫秒和 0-200 毫秒)。研究共分为三个阶段:第一次观察包括初始观察(观察 1A),30 分钟后进行第二次观察(观察 1B),以获得观察期间的可靠性;第二次观察在一周后进行,包括第三次观察(观察 2),以获得观察期间的可靠性:共有 51 人参加了研究。早期阶段 RFD 的会话内类间相关系数为 0.87(95% CI,0.74-0.92),晚期阶段为 0.91 至 0.92(95% CI,0.87-0.94)。早期阶段 RFD 的会话间类内相关系数为 0.83 至 0.86(95% CI,0.74-0.91),晚期阶段为 0.87 至 0.90(95% CI,0.80-0.94)。最后,峰值力的类内相关系数在疗程内为.95(95% CI,.92-.97),在疗程间为.91-.92(95% CI,.86-.95):我们的方法为评估膝关节伸肌的 RFD 和峰值力提供了一种可靠、经济、快速的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Sport Rehabilitation
Journal of Sport Rehabilitation 医学-康复医学
CiteScore
3.20
自引率
5.90%
发文量
143
审稿时长
>12 weeks
期刊介绍: The Journal of Sport Rehabilitation (JSR) is your source for the latest peer-reviewed research in the field of sport rehabilitation. All members of the sports-medicine team will benefit from the wealth of important information in each issue. JSR is completely devoted to the rehabilitation of sport and exercise injuries, regardless of the age, gender, sport ability, level of fitness, or health status of the participant. JSR publishes peer-reviewed original research, systematic reviews/meta-analyses, critically appraised topics (CATs), case studies/series, and technical reports that directly affect the management and rehabilitation of injuries incurred during sport-related activities, irrespective of the individual’s age, gender, sport ability, level of fitness, or health status. The journal is intended to provide an international, multidisciplinary forum to serve the needs of all members of the sports medicine team, including athletic trainers/therapists, sport physical therapists/physiotherapists, sports medicine physicians, and other health care and medical professionals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信