Pierre-Henri Vermorel, Carlo Ciccullo, Luca De Berardinis, Antonio Pompilo Gigante, Thomas Neri, Rémi Philippot
{"title":"Does robotic arm-assisted total knee arthroplasty have a role to play in large deformities?","authors":"Pierre-Henri Vermorel, Carlo Ciccullo, Luca De Berardinis, Antonio Pompilo Gigante, Thomas Neri, Rémi Philippot","doi":"10.1051/sicotj/2024046","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Total knee arthroplasty (TKA) for patients with a large preoperative deformity (more than 10° varus or valgus) remains a challenge leading to a high rate of outliers, unsatisfactory functional results, or early prosthetic loosening. Robotic arm-assisted TKA (RATKA) has shown improvements in implant positioning accuracy. This study aimed to assess RATKA implant positioning accuracy and functional results at one year postoperative for patients with a large preoperative deformity.</p><p><strong>Methods: </strong>From November 2019 to July 2022, 500 RATKA were performed. About 74 patients with more than 10° of varus or valgus global deformity were included. Each patient received a semi-constrained implant. The difference between the valgus or varus value planned intra-operatively and the varus or valgus measured on one-year postoperative X-rays has been assessed. Functional outcomes (VAS, range of motion, KOOS) have also been evaluated.</p><p><strong>Results: </strong>For varus, the mean difference was 0.54 ± 1.21°, all patients (100%) had a difference of less than 3° at one-year post-operative. For valgus, the mean difference was 0.63 ± 1.29°, most patients (92%) had a difference of less than 3° at one year postoperative. Overall, 98.6% (n = 73) of cases had a difference of less than 3° at one-year postoperative. The mean VAS was 1.6 ± 1.4 [1;4]. Mean flexion was 132 ± 7.6° [100;145]. A total of 69 patients (93%) had a good or excellent KOOS score (KOOS total > 70) at one year post-operative.</p><p><strong>Conclusion: </strong>For large preoperative deformities, RATKA provides a high degree of accuracy in implant positioning, permitting it to fit the desired alignment without compromising knee stability, and giving the possibility of using semi-constrained implants. At one year postoperative, functional results are encouraging and most patients have recovered an optimal range of motions.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":"10 ","pages":"50"},"PeriodicalIF":1.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2024046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Total knee arthroplasty (TKA) for patients with a large preoperative deformity (more than 10° varus or valgus) remains a challenge leading to a high rate of outliers, unsatisfactory functional results, or early prosthetic loosening. Robotic arm-assisted TKA (RATKA) has shown improvements in implant positioning accuracy. This study aimed to assess RATKA implant positioning accuracy and functional results at one year postoperative for patients with a large preoperative deformity.
Methods: From November 2019 to July 2022, 500 RATKA were performed. About 74 patients with more than 10° of varus or valgus global deformity were included. Each patient received a semi-constrained implant. The difference between the valgus or varus value planned intra-operatively and the varus or valgus measured on one-year postoperative X-rays has been assessed. Functional outcomes (VAS, range of motion, KOOS) have also been evaluated.
Results: For varus, the mean difference was 0.54 ± 1.21°, all patients (100%) had a difference of less than 3° at one-year post-operative. For valgus, the mean difference was 0.63 ± 1.29°, most patients (92%) had a difference of less than 3° at one year postoperative. Overall, 98.6% (n = 73) of cases had a difference of less than 3° at one-year postoperative. The mean VAS was 1.6 ± 1.4 [1;4]. Mean flexion was 132 ± 7.6° [100;145]. A total of 69 patients (93%) had a good or excellent KOOS score (KOOS total > 70) at one year post-operative.
Conclusion: For large preoperative deformities, RATKA provides a high degree of accuracy in implant positioning, permitting it to fit the desired alignment without compromising knee stability, and giving the possibility of using semi-constrained implants. At one year postoperative, functional results are encouraging and most patients have recovered an optimal range of motions.