{"title":"Statistical biases correction in channelized Hotelling model observers.","authors":"Lionel Desponds","doi":"10.1088/1361-6560/ad9541","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Channelized Hotelling model observers are efficient at simulating the human observer visual performance in medical imaging detection tasks. However, channelized Hotelling observers (CHO) are subject to statistical biases from zero-signal and finite-sample effects. The point estimate of the d' value is also not always symmetric with exact confidence interval (CI) bounds determined for the infinitely trained CHO. A method for correcting these statistical biases and CI asymmetry is studied.</p><p><strong>Approach: </strong>CHO d' values and CI bounds with hold-out and resubstitution methods were computed for a range of 200x200 pixels images from 20 to 10 000 images for 10, 40 and 96 channels from a set of 20 000 images with gaussian coloured simulated noise and simulated signal. The median of the non-central F cumulative distribution (F'), which is the CHO underlying statistical behaviour for the resubstitution method, was computed, and compared to d' values and CI bounds. A set of experimental data was used to evaluate F' median values.</p><p><strong>Main results: </strong>The F' median allows to get accurate corrected simulated d' values down to zero-signals. For small d' values, the variation of d' values with the inverse of number of images is not linear while the F' median allows a good correction in such conditions. The F' median is also inherently symmetric with regards to the confidence interval. With experimental data, F' median values in a range of about 1 to 10 d' values were within -0.8% to 4.7% of linearly extrapolated values at an infinite number of images.</p><p><strong>Significance: </strong>The F' median correction is an effective simultaneous correction of the zero-signal statistical bias and finite-sample statistical bias, and of confidence interval asymmetry of channelized Hotelling observers.
.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ad9541","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Channelized Hotelling model observers are efficient at simulating the human observer visual performance in medical imaging detection tasks. However, channelized Hotelling observers (CHO) are subject to statistical biases from zero-signal and finite-sample effects. The point estimate of the d' value is also not always symmetric with exact confidence interval (CI) bounds determined for the infinitely trained CHO. A method for correcting these statistical biases and CI asymmetry is studied.
Approach: CHO d' values and CI bounds with hold-out and resubstitution methods were computed for a range of 200x200 pixels images from 20 to 10 000 images for 10, 40 and 96 channels from a set of 20 000 images with gaussian coloured simulated noise and simulated signal. The median of the non-central F cumulative distribution (F'), which is the CHO underlying statistical behaviour for the resubstitution method, was computed, and compared to d' values and CI bounds. A set of experimental data was used to evaluate F' median values.
Main results: The F' median allows to get accurate corrected simulated d' values down to zero-signals. For small d' values, the variation of d' values with the inverse of number of images is not linear while the F' median allows a good correction in such conditions. The F' median is also inherently symmetric with regards to the confidence interval. With experimental data, F' median values in a range of about 1 to 10 d' values were within -0.8% to 4.7% of linearly extrapolated values at an infinite number of images.
Significance: The F' median correction is an effective simultaneous correction of the zero-signal statistical bias and finite-sample statistical bias, and of confidence interval asymmetry of channelized Hotelling observers.
.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry