{"title":"Ultrasound-guided thrombin injection for cardiac catheterization pseudoaneurysms: efficacy, safety, and predictors.","authors":"Edgar Bortolini, Tulio Fabiano de Oliveira Leite, Bruno Renan Ribeiro Gomes Linard, Breno Boueri Affonso, Cesar Higa Nomura, Joaquim Mauricio da Motta-Leal-Filho","doi":"10.1177/02841851241292516","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Percutaneous ultrasound-guided thrombin injection has become the gold standard treatment for pseudoaneurysms caused by cardiac catheterization. However, failure can occur in up to 25% of the procedures and little is known about its causes.</p><p><strong>Purpose: </strong>To study the efficacy and safety of the technique and to determine possible risk factors responsible for the unsuccess.</p><p><strong>Material and methods: </strong>A cohort study was carried out based on data from medical records collected between December 2012 and June 2020 of 110 patients with the diagnosis of pseudoaneurysm, femoral or radial, secondary to cardiac catheterization. Clinical data, pseudoaneurysm morphological parameters, and technical factors related to catheterization were reviewed.</p><p><strong>Results: </strong>Primary and global technical success rates were 85.5% and 100%, respectively. Age, neck, and anteroposterior diameter variables were predictors of primary failure on multivariate analysis. The odds ratio (OR) for age was 0.960 (95% confidence interval [CI]=0.927-0.995; <i>P</i> = 0.025), for anteroposterior diameter, OR was 2.023 (95% CI=1.144-3.578; <i>P</i> = 0.015), and for neck diameter, it was 4.625 (95% CI=1.023-20.904; <i>P</i> = 0.047). The receiver operating characteristic (ROC) curve was performed for the multivariate analysis model and the three predictors of failure. The area under the curve for the multivariate analysis model was 0.695, for age it was 0.675, for anteroposterior diameter it was 0.679, and for neck diameter it was 0.676. No complications were observed.</p><p><strong>Conclusions: </strong>Percutaneous ultrasound-guided thrombin injection is safe and effective for the treatment of pseudoaneurysms after cardiac catheterization. Largest anteroposterior diameter, largest neck diameter, and a younger age were independent predictors of primary failure with the technique.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"2841851241292516"},"PeriodicalIF":1.1000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241292516","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Percutaneous ultrasound-guided thrombin injection has become the gold standard treatment for pseudoaneurysms caused by cardiac catheterization. However, failure can occur in up to 25% of the procedures and little is known about its causes.

Purpose: To study the efficacy and safety of the technique and to determine possible risk factors responsible for the unsuccess.

Material and methods: A cohort study was carried out based on data from medical records collected between December 2012 and June 2020 of 110 patients with the diagnosis of pseudoaneurysm, femoral or radial, secondary to cardiac catheterization. Clinical data, pseudoaneurysm morphological parameters, and technical factors related to catheterization were reviewed.

Results: Primary and global technical success rates were 85.5% and 100%, respectively. Age, neck, and anteroposterior diameter variables were predictors of primary failure on multivariate analysis. The odds ratio (OR) for age was 0.960 (95% confidence interval [CI]=0.927-0.995; P = 0.025), for anteroposterior diameter, OR was 2.023 (95% CI=1.144-3.578; P = 0.015), and for neck diameter, it was 4.625 (95% CI=1.023-20.904; P = 0.047). The receiver operating characteristic (ROC) curve was performed for the multivariate analysis model and the three predictors of failure. The area under the curve for the multivariate analysis model was 0.695, for age it was 0.675, for anteroposterior diameter it was 0.679, and for neck diameter it was 0.676. No complications were observed.

Conclusions: Percutaneous ultrasound-guided thrombin injection is safe and effective for the treatment of pseudoaneurysms after cardiac catheterization. Largest anteroposterior diameter, largest neck diameter, and a younger age were independent predictors of primary failure with the technique.

超声引导下凝血酶注射治疗心导管假性动脉瘤:疗效、安全性和预测因素。
背景:经皮超声引导注射凝血酶已成为治疗心导管手术引起的假性动脉瘤的金标准。目的:研究该技术的有效性和安全性,并确定导致治疗失败的可能风险因素:根据 2012 年 12 月至 2020 年 6 月期间收集的病历数据,对 110 例心导管检查后诊断为股动脉或桡动脉假性动脉瘤的患者进行了队列研究。对临床数据、假动脉瘤形态参数以及与导管术相关的技术因素进行了回顾:初诊成功率和总体技术成功率分别为 85.5%和 100%。年龄、颈部和前胸直径变量是多变量分析中预测初次失败的因素。年龄的比值比(OR)为0.960(95% 置信区间[CI]=0.927-0.995;P = 0.025),前胸直径的比值比为2.023(95% CI=1.144-3.578;P = 0.015),颈部直径的比值比为4.625(95% CI=1.023-20.904;P = 0.047)。对多变量分析模型和三个失败预测因素进行了接收者操作特征曲线(ROC)分析。多变量分析模型的曲线下面积为 0.695,年龄为 0.675,前胸直径为 0.679,颈部直径为 0.676。未观察到并发症:结论:经皮超声引导注射凝血酶治疗心导管术后假性动脉瘤安全有效。最大的前胸直径、最大的颈部直径和较小的年龄是该技术初次失败的独立预测因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta radiologica
Acta radiologica 医学-核医学
CiteScore
2.70
自引率
0.00%
发文量
170
审稿时长
3-8 weeks
期刊介绍: Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信