Occlusal parameters and wear of artificial teeth in complete dentures with lingualized versus bilateral balanced occlusion: a randomized clinical trial.
Zhiqiang Wang, Yan Su, Jianmin Wang, Yang Liu, Wenzhong Xing
{"title":"Occlusal parameters and wear of artificial teeth in complete dentures with lingualized versus bilateral balanced occlusion: a randomized clinical trial.","authors":"Zhiqiang Wang, Yan Su, Jianmin Wang, Yang Liu, Wenzhong Xing","doi":"10.1186/s12903-024-05144-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to assess the occlusal contact area (OCA), occlusal contact number (OCN), bite force, and artificial tooth wear in complete dentures with lingualized and bilateral balanced occlusion.</p><p><strong>Methods: </strong>Edentulous participants who fulfilled the inclusion criteria were divided into the three groups as follows: group I, dentures with lingualized occlusion using interpenetrating polymer network artificial teeth; group II, dentures with lingualized occlusion using double cross-linked artificial teeth; and group III, dentures with bilateral balanced occlusion using anatomical micro-hybrid resin teeth. The silicone techniques were used to assess the OCA and OCN of the mandibular dentures and the Dental Prescale II was used to evaluate the bite force at the 2-week, 3-month, and 12-month follow-up visits. Occlusal contact analyzer software was used to assess the maxillary and mandibular posterior tooth wear at the 12-month follow-up visit. All data was analyzed using the SPSS software.</p><p><strong>Results: </strong>The OCA of group III was significantly higher than that of groups I and II at the 2-week follow-up visit, whereas group I was considerably higher than groups II and III at the 3-month and 12-month follow-up visits. The OCN of the three groups exhibited significant differences at all three follow-up visits. Groups I and II had significantly lower bite force than Group III at the three follow-up visits. At the 12-month follow-up visit, groups I and II had significantly higher wear than Group III.</p><p><strong>Conclusions: </strong>As the duration of use increases, the occlusal contact area of complete dentures increases, regardless of the occlusal schemes. The bite force of lingualized occlusion is typically lower than that of bilateral balanced occlusion. The wear locations of artificial teeth differ between the two types of occlusal schemes. (Retrospectively registered: The Chinese Clinical Trial Registry, No. ChiCTR2300073420(11/07/2023)).</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"24 1","pages":"1405"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11575096/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-024-05144-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This study aimed to assess the occlusal contact area (OCA), occlusal contact number (OCN), bite force, and artificial tooth wear in complete dentures with lingualized and bilateral balanced occlusion.
Methods: Edentulous participants who fulfilled the inclusion criteria were divided into the three groups as follows: group I, dentures with lingualized occlusion using interpenetrating polymer network artificial teeth; group II, dentures with lingualized occlusion using double cross-linked artificial teeth; and group III, dentures with bilateral balanced occlusion using anatomical micro-hybrid resin teeth. The silicone techniques were used to assess the OCA and OCN of the mandibular dentures and the Dental Prescale II was used to evaluate the bite force at the 2-week, 3-month, and 12-month follow-up visits. Occlusal contact analyzer software was used to assess the maxillary and mandibular posterior tooth wear at the 12-month follow-up visit. All data was analyzed using the SPSS software.
Results: The OCA of group III was significantly higher than that of groups I and II at the 2-week follow-up visit, whereas group I was considerably higher than groups II and III at the 3-month and 12-month follow-up visits. The OCN of the three groups exhibited significant differences at all three follow-up visits. Groups I and II had significantly lower bite force than Group III at the three follow-up visits. At the 12-month follow-up visit, groups I and II had significantly higher wear than Group III.
Conclusions: As the duration of use increases, the occlusal contact area of complete dentures increases, regardless of the occlusal schemes. The bite force of lingualized occlusion is typically lower than that of bilateral balanced occlusion. The wear locations of artificial teeth differ between the two types of occlusal schemes. (Retrospectively registered: The Chinese Clinical Trial Registry, No. ChiCTR2300073420(11/07/2023)).
研究目的本研究旨在评估舌侧化咬合和双侧平衡咬合全口义齿的咬合接触面积(OCA)、咬合接触数(OCN)、咬合力和人工牙磨损情况:将符合纳入标准的无牙患者分为以下三组:第一组,使用互穿聚合物网络人工牙的舌侧咬合假牙;第二组,使用双交联人工牙的舌侧咬合假牙;第三组,使用解剖微混合树脂牙的双侧平衡咬合假牙。硅胶技术用于评估下颌义齿的 OCA 和 OCN,Dental Prescale II 用于评估 2 周、3 个月和 12 个月复诊时的咬合力。在 12 个月复诊时,使用咬合接触分析仪软件评估上颌和下颌后牙磨损情况。所有数据均使用 SPSS 软件进行分析:结果:在 2 周随访时,III 组的 OCA 明显高于 I 组和 II 组,而在 3 个月和 12 个月随访时,I 组的 OCA 明显高于 II 组和 III 组。三组的 OCN 在三次随访中均有显著差异。在三次随访中,第一组和第二组的咬合力明显低于第三组。在 12 个月的随访中,第一组和第二组的磨损程度明显高于第三组:结论:随着使用时间的延长,无论采用哪种咬合方案,全口义齿的咬合接触面积都会增加。舌侧咬合的咬合力通常低于双侧平衡咬合。两种咬合方案的人工牙磨损位置不同。(回顾性注册:中国临床试验注册中心,编号:ChiCTR2300073420(11/07/2023))。
期刊介绍:
BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.