Investigation and insights on the on-demand generation of monodispersed emulsion droplets from a floating capillary-based open microfluidic device.

IF 3.1 2区 化学 Q3 CHEMISTRY, PHYSICAL
Yueming Deng, Shuting Xie, Zhengguang Li, Ruizhi Yang, Zhenping Liu, Jiyuan Yao, Haopeng Zhang, Mingliang Jin, Lingling Shui
{"title":"Investigation and insights on the on-demand generation of monodispersed emulsion droplets from a floating capillary-based open microfluidic device.","authors":"Yueming Deng, Shuting Xie, Zhengguang Li, Ruizhi Yang, Zhenping Liu, Jiyuan Yao, Haopeng Zhang, Mingliang Jin, Lingling Shui","doi":"10.1063/5.0234937","DOIUrl":null,"url":null,"abstract":"<p><p>Simple and stable generation of monodispersed droplets with volume from picolitre to nanoliter is one of the key factors in high-throughput quantitative microreactors for chemical and biomedical applications. In this work, an efficient method that could realize simple manipulating microflow with a broad operation window for preparing monodispersed droplets with controllable diameter is developed. The microfluidic device is constructed by inserting a capillary with an oblique angle (α) into the continuous phase, named a floating capillary-based open microfluidic device (FCOMD). The transition of droplet-generating mode between dripping and jetting can be achieved by changing capillary number and α. A computational model based on the volume-of-fluid/continuum-surface-force method to explain the controllability of α on the droplet formation regime and droplet breakage, verifying the synergistic effect of ΔP and Fb, facilitates the droplet pinching. A descending order of Pn of capillary with different α is that 45° > 30° > 15° > 60° > 75°, leading to the same order of generated droplet's D. When compared with the traditional capillary co-flow device, the generating throughput of the integrated FCOMD obtained by integrating different numbers of capillaries is at least ten times. Moreover, water in oil, oil in water double-emulsion, colloidal dispersed droplets, and liquid crystal droplets with diameters ranging from 25 to 800 μm are prepared on-demand by the FCOMD, indicating the universality of the microfluidic device. Thus, the FCOMD shows the features of simplicity, practicability, and flexibility, offering valuable guidance for generating controllable droplets with wide size change and showing a great potential application in material science, foods, pharmaceuticals, and cosmetics.</p>","PeriodicalId":15313,"journal":{"name":"Journal of Chemical Physics","volume":"161 19","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemical Physics","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1063/5.0234937","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Simple and stable generation of monodispersed droplets with volume from picolitre to nanoliter is one of the key factors in high-throughput quantitative microreactors for chemical and biomedical applications. In this work, an efficient method that could realize simple manipulating microflow with a broad operation window for preparing monodispersed droplets with controllable diameter is developed. The microfluidic device is constructed by inserting a capillary with an oblique angle (α) into the continuous phase, named a floating capillary-based open microfluidic device (FCOMD). The transition of droplet-generating mode between dripping and jetting can be achieved by changing capillary number and α. A computational model based on the volume-of-fluid/continuum-surface-force method to explain the controllability of α on the droplet formation regime and droplet breakage, verifying the synergistic effect of ΔP and Fb, facilitates the droplet pinching. A descending order of Pn of capillary with different α is that 45° > 30° > 15° > 60° > 75°, leading to the same order of generated droplet's D. When compared with the traditional capillary co-flow device, the generating throughput of the integrated FCOMD obtained by integrating different numbers of capillaries is at least ten times. Moreover, water in oil, oil in water double-emulsion, colloidal dispersed droplets, and liquid crystal droplets with diameters ranging from 25 to 800 μm are prepared on-demand by the FCOMD, indicating the universality of the microfluidic device. Thus, the FCOMD shows the features of simplicity, practicability, and flexibility, offering valuable guidance for generating controllable droplets with wide size change and showing a great potential application in material science, foods, pharmaceuticals, and cosmetics.

基于浮动毛细管的开放式微流体装置按需生成单分散乳液液滴的研究与见解。
简单稳定地生成体积从皮升到纳升的单分散液滴是化学和生物医学应用领域高通量定量微反应器的关键因素之一。在这项工作中,我们开发了一种高效的方法,可以实现简单的微流操作,并具有宽广的操作窗口,用于制备直径可控的单分散液滴。这种微流控装置是通过在连续相中插入一个具有斜角(α)的毛细管而构建的,被命名为基于浮动毛细管的开放式微流控装置(FCOMD)。通过改变毛细管数量和 α 可以实现液滴产生模式在滴流和喷射之间的转换。基于流体体积/连续表面力方法的计算模型解释了 α 对液滴形成机制和液滴破碎的可控性,验证了 ΔP 和 Fb 的协同效应,促进了液滴捏合。不同 α 的毛细管 Pn 从大到小的顺序为 45° > 30° > 15° > 60° > 75°,从而导致产生的液滴 D 顺序相同。与传统的毛细管同流装置相比,通过整合不同数量的毛细管而获得的集成 FCOMD 的生成吞吐量至少增加了十倍。此外,FCOMD 还能按需制备油包水、油包水双乳液、胶体分散液滴以及直径从 25 μm 到 800 μm 的液晶液滴,这表明该微流体装置具有通用性。因此,FCOMD 显示出简单、实用和灵活的特点,为生成尺寸变化大的可控液滴提供了宝贵的指导,在材料科学、食品、制药和化妆品等领域显示出巨大的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Chemical Physics
Journal of Chemical Physics 物理-物理:原子、分子和化学物理
CiteScore
7.40
自引率
15.90%
发文量
1615
审稿时长
2 months
期刊介绍: The Journal of Chemical Physics publishes quantitative and rigorous science of long-lasting value in methods and applications of chemical physics. The Journal also publishes brief Communications of significant new findings, Perspectives on the latest advances in the field, and Special Topic issues. The Journal focuses on innovative research in experimental and theoretical areas of chemical physics, including spectroscopy, dynamics, kinetics, statistical mechanics, and quantum mechanics. In addition, topical areas such as polymers, soft matter, materials, surfaces/interfaces, and systems of biological relevance are of increasing importance. Topical coverage includes: Theoretical Methods and Algorithms Advanced Experimental Techniques Atoms, Molecules, and Clusters Liquids, Glasses, and Crystals Surfaces, Interfaces, and Materials Polymers and Soft Matter Biological Molecules and Networks.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信