Acoustic radiation force impulse (push pulse)-induced lung hemorrhage: investigating the effect of ultrasound contrast agent in rabbits.

IF 1.9 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Noriya Takayama, Hideki Sasanuma, Kazuma Rifu, Naotaka Nitta, Iwaki Akiyama, Nobuyuki Taniguchi
{"title":"Acoustic radiation force impulse (push pulse)-induced lung hemorrhage: investigating the effect of ultrasound contrast agent in rabbits.","authors":"Noriya Takayama, Hideki Sasanuma, Kazuma Rifu, Naotaka Nitta, Iwaki Akiyama, Nobuyuki Taniguchi","doi":"10.1007/s10396-024-01510-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Acoustic radiation force impulse (ARFI) elastography and contrast-enhanced ultrasonography (CEUS) are emerging techniques that are becoming common in ultrasound examinations. We previously reported that ARFI (push pulse) induced lung hemorrhage in rabbits, indicating that greater risks are associated with ARFI than with conventional ultrasound. In this study, we assessed the risk of lung hemorrhage under a combination of ARFI elastography and CEUS, considering potential exacerbation of ARFI-induced lung hemorrhage as a result of the ultrasound contrast agent (UCA) used in CEUS.</p><p><strong>Methods: </strong>Twenty-three rabbits were divided into non-UCA and UCA groups. ARFI exposure parameters were set at six mechanical index (MI) levels (0.29, 0.45, 0.60, 0.88, 1.0, 1.39) in non-UCA groups and five MI levels (0.29, 0.66, 0.88, 0.97, 1.25) in UCA groups. Lung exposure was performed bilaterally through the intercostal space in each rabbit. Lung damage was assessed through macroscopic and microscopic observation post euthanasia.</p><p><strong>Results: </strong>Lung hemorrhage was detected at MI<sub>0.3</sub> levels of 0.88 or higher. Logistic regression analyses showed that MI<sub>0.3</sub> was a statistically significant factor for occurrence of lung hemorrhage in both non-UCA and UCA groups, and the MI<sub>0.3</sub> threshold (ED<sub>05</sub>) for inducing lung hemorrhage was 0.68 and 0.71, respectively. However, multivariate logistic regression and linear regression analyses across all samples indicated that UCA did not significantly affect the occurrence or area of lung hemorrhage.</p><p><strong>Conclusion: </strong>This study demonstrates that UCA does not significantly worsen ARFI-induced lung hemorrhage in terms of occurrence or severity. However, risks and benefits of ARFI elastography on the lung should be considered, irrespective of UCA administration.</p>","PeriodicalId":50130,"journal":{"name":"Journal of Medical Ultrasonics","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Ultrasonics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10396-024-01510-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Acoustic radiation force impulse (ARFI) elastography and contrast-enhanced ultrasonography (CEUS) are emerging techniques that are becoming common in ultrasound examinations. We previously reported that ARFI (push pulse) induced lung hemorrhage in rabbits, indicating that greater risks are associated with ARFI than with conventional ultrasound. In this study, we assessed the risk of lung hemorrhage under a combination of ARFI elastography and CEUS, considering potential exacerbation of ARFI-induced lung hemorrhage as a result of the ultrasound contrast agent (UCA) used in CEUS.

Methods: Twenty-three rabbits were divided into non-UCA and UCA groups. ARFI exposure parameters were set at six mechanical index (MI) levels (0.29, 0.45, 0.60, 0.88, 1.0, 1.39) in non-UCA groups and five MI levels (0.29, 0.66, 0.88, 0.97, 1.25) in UCA groups. Lung exposure was performed bilaterally through the intercostal space in each rabbit. Lung damage was assessed through macroscopic and microscopic observation post euthanasia.

Results: Lung hemorrhage was detected at MI0.3 levels of 0.88 or higher. Logistic regression analyses showed that MI0.3 was a statistically significant factor for occurrence of lung hemorrhage in both non-UCA and UCA groups, and the MI0.3 threshold (ED05) for inducing lung hemorrhage was 0.68 and 0.71, respectively. However, multivariate logistic regression and linear regression analyses across all samples indicated that UCA did not significantly affect the occurrence or area of lung hemorrhage.

Conclusion: This study demonstrates that UCA does not significantly worsen ARFI-induced lung hemorrhage in terms of occurrence or severity. However, risks and benefits of ARFI elastography on the lung should be considered, irrespective of UCA administration.

声辐射力脉冲(推脉冲)诱发肺出血:研究超声造影剂对兔子的影响。
目的:声辐射力脉冲(ARFI)弹性成像和造影剂增强超声波成像(CEUS)是新兴技术,在超声波检查中越来越常见。我们以前曾报道过 ARFI(推脉冲)会诱发兔子肺出血,这表明 ARFI 比传统超声检查具有更大的风险。在本研究中,考虑到 CEUS 中使用的超声造影剂(UCA)可能会加重 ARFI 引起的肺出血,我们评估了 ARFI 弹性成像和 CEUS 联合使用时发生肺出血的风险:方法:23 只兔子分为非 UCA 组和 UCA 组。非 UCA 组的 ARFI 曝光参数设置为六个机械指数 (MI) 水平(0.29、0.45、0.60、0.88、1.0、1.39),UCA 组的 ARFI 曝光参数设置为五个 MI 水平(0.29、0.66、0.88、0.97、1.25)。对每只兔子的肺部进行双侧肋间隙暴露。安乐死后通过宏观和微观观察评估肺损伤情况:结果:当MI0.3水平达到或超过0.88时,可检测到肺出血。逻辑回归分析表明,MI0.3是非UCA组和UCA组发生肺出血的重要统计学因素,诱发肺出血的MI0.3阈值(ED05)分别为0.68和0.71。然而,对所有样本进行的多变量逻辑回归和线性回归分析表明,UCA对肺出血的发生率和面积没有显著影响:本研究表明,就发生率和严重程度而言,UCA 不会明显恶化 ARFI 引起的肺出血。然而,无论是否使用 UCA,都应考虑 ARFI 弹性成像对肺部的风险和益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
11.10%
发文量
102
审稿时长
>12 weeks
期刊介绍: The Journal of Medical Ultrasonics is the official journal of the Japan Society of Ultrasonics in Medicine. The main purpose of the journal is to provide forum for the publication of papers documenting recent advances and new developments in the entire field of ultrasound in medicine and biology, encompassing both the medical and the engineering aspects of the science.The journal welcomes original articles, review articles, images, and letters to the editor.The journal also provides state-of-the-art information such as announcements from the boards and the committees of the society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信