The validation of an LC-MS/MS method for the quantification of vitamin D metabolites in human milk and their biological variability in Gambian women

IF 2.7 2区 生物学 Q3 BIOCHEMISTRY & MOLECULAR BIOLOGY
Kerry S. Jones , Sarah R. Meadows , Georgia Billing , Albert Koulman , Ann Prentice
{"title":"The validation of an LC-MS/MS method for the quantification of vitamin D metabolites in human milk and their biological variability in Gambian women","authors":"Kerry S. Jones ,&nbsp;Sarah R. Meadows ,&nbsp;Georgia Billing ,&nbsp;Albert Koulman ,&nbsp;Ann Prentice","doi":"10.1016/j.jsbmb.2024.106633","DOIUrl":null,"url":null,"abstract":"<div><div>Vitamin D is required for healthy growth and development, but data on human milk vitamin D content is limited. We describe a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of vitamin D metabolites in human milk, and its application in samples collected on two consecutive days from women in rural Gambia. Vitamin D compounds were extracted from 1 mL of milk by liquid-liquid extraction and derivatised with 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD) prior to analysis by LC-MS/MS. The limit of quantification was 0.05 nmol/L for vitamin D<sub>2</sub>, 0.025 nmol/L for vitamin D<sub>3</sub> and 0.1 nmol/L for 25(OH)D<sub>2</sub> and 25(OH)D<sub>3</sub>. Within- and between-day imprecision was &lt;12 % for all analytes except vitamin D<sub>2</sub> (14 %).</div><div>From all data combined, geometric mean (-/+ 1 SD) vitamin D<sub>3</sub> concentration was 0.94 (0.43, 1.80) nmol/L and for 25(OH)D<sub>3</sub> 0.32 (0.23, 0.42) nmol/L. The within-person (intra-individual) coefficient of variation (%CV) was 32 % and 12 % for vitamin D<sub>3</sub> and 25(OH)D<sub>3</sub>, respectively. Between-person (inter-individual) %CVs were 89 % and 34 % for vitamin D<sub>3</sub> and 25(OH)D<sub>3</sub>, respectively. There was no significant association between vitamin D metabolite concentrations and milk fat (creamatocrit). Mean vitamin D content of human milk as ARA averaged 42 IU/L with 25(OH)D<sub>3</sub> responsible for around two-thirds of the biological activity. In conclusion, this work describes a reliable LC-MS/MS method for quantification of vitamin D and 25(OH)D in low volumes of human milk providing a platform for future work. This study contributes to current understanding of variability of milk vitamin D content.</div></div>","PeriodicalId":51106,"journal":{"name":"Journal of Steroid Biochemistry and Molecular Biology","volume":"245 ","pages":"Article 106633"},"PeriodicalIF":2.7000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Steroid Biochemistry and Molecular Biology","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S096007602400181X","RegionNum":2,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Vitamin D is required for healthy growth and development, but data on human milk vitamin D content is limited. We describe a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of vitamin D metabolites in human milk, and its application in samples collected on two consecutive days from women in rural Gambia. Vitamin D compounds were extracted from 1 mL of milk by liquid-liquid extraction and derivatised with 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD) prior to analysis by LC-MS/MS. The limit of quantification was 0.05 nmol/L for vitamin D2, 0.025 nmol/L for vitamin D3 and 0.1 nmol/L for 25(OH)D2 and 25(OH)D3. Within- and between-day imprecision was <12 % for all analytes except vitamin D2 (14 %).
From all data combined, geometric mean (-/+ 1 SD) vitamin D3 concentration was 0.94 (0.43, 1.80) nmol/L and for 25(OH)D3 0.32 (0.23, 0.42) nmol/L. The within-person (intra-individual) coefficient of variation (%CV) was 32 % and 12 % for vitamin D3 and 25(OH)D3, respectively. Between-person (inter-individual) %CVs were 89 % and 34 % for vitamin D3 and 25(OH)D3, respectively. There was no significant association between vitamin D metabolite concentrations and milk fat (creamatocrit). Mean vitamin D content of human milk as ARA averaged 42 IU/L with 25(OH)D3 responsible for around two-thirds of the biological activity. In conclusion, this work describes a reliable LC-MS/MS method for quantification of vitamin D and 25(OH)D in low volumes of human milk providing a platform for future work. This study contributes to current understanding of variability of milk vitamin D content.
验证用于定量检测冈比亚妇女母乳中维生素 D 代谢物及其生物变异性的 LC-MS/MS 方法。
健康的生长发育需要维生素 D,但有关母乳中维生素 D 含量的数据却很有限。我们介绍了一种用于分析母乳中维生素 D 代谢物的液相色谱串联质谱(LC-MS/MS)方法,以及该方法在冈比亚农村妇女连续两天采集的样本中的应用。用液液萃取法从 1 毫升牛奶中提取维生素 D 复合物,并用 4-苯基-1,2,4-三唑啉-3,5-二酮(PTAD)衍生,然后用 LC-MS/MS 进行分析。维生素 D2 的定量限为 0.05 nmol/L,维生素 D3 为 0.025 nmol/L,25(OH)D2 和 25(OH)D3 为 0.1 nmol/L。日内和日间不精确度为 2(14%)。综合所有数据,维生素 D3 浓度的几何平均数(-/+ 1SD)为 0.94 (0.43, 1.80) nmol/L,25(OH)D3 为 0.32 (0.23, 0.42) nmol/L。维生素 D3 和 25(OH)D3 的个体内变异系数 (%CV) 分别为 32% 和 12%。维生素 D3 和 25(OH)D3 的个体间变异系数分别为 89% 和 34%。维生素 D 代谢物浓度与乳脂(乳脂率)之间无明显关联。人乳中作为 ARA 的维生素 D 平均含量为 42 IU/L,其中 25(OH)D3 约占生物活性的三分之二。总之,这项工作描述了一种可靠的 LC-MS/MS 方法,用于定量检测低浓度母乳中的维生素 D 和 25(OH)D,为今后的工作提供了一个平台。这项研究有助于人们了解牛奶中维生素 D 含量的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.60
自引率
2.40%
发文量
113
审稿时长
46 days
期刊介绍: The Journal of Steroid Biochemistry and Molecular Biology is devoted to new experimental and theoretical developments in areas related to steroids including vitamin D, lipids and their metabolomics. The Journal publishes a variety of contributions, including original articles, general and focused reviews, and rapid communications (brief articles of particular interest and clear novelty). Selected cutting-edge topics will be addressed in Special Issues managed by Guest Editors. Special Issues will contain both commissioned reviews and original research papers to provide comprehensive coverage of specific topics, and all submissions will undergo rigorous peer-review prior to publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信