The Accuracy of Intraoral Scanners in Maxillary Defects with Different Model Variations.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Sema Murat, Burcu Batak, Özge Aydoğ, Caner Öztürk
{"title":"The Accuracy of Intraoral Scanners in Maxillary Defects with Different Model Variations.","authors":"Sema Murat, Burcu Batak, Özge Aydoğ, Caner Öztürk","doi":"10.3390/diagnostics14212368","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Advances in digital technology and intraoral scanners (IOSs) have the potential to enable accurate digital impressions for patients with maxillary defects. This study aimed to compare the accuracy of IOSs in completely and partially edentulous models with maxillary defects. <b>Methods:</b> Three polyurethane models-one completely edentulous (CE) and two partially edentulous, following Aramany classifications I (ACI) and II (ACII)-were created using stereolithography. These models were scanned with a desktop scanner to create reference models. Ten scans were performed using three different intraoral scanners (TRIOS 3, Primescan, and Virtuo Vivo). The IOS datasets were analyzed to assess trueness and precision using a two-way ANOVA and multiple-comparison tests with Bonferroni corrections (α = 0.05). <b>Results:</b> Both the model type and the IOS significantly influenced trueness and precision. The interaction between the model type and the IOS was found to be statistically significant (trueness: <i>p</i> = 0.001; precision: <i>p</i> = 0.005). The highest trueness was observed in the ACII model scanned with TRIOS 3 and Primescan. TRIOS 3 and Primescan also exhibited the highest precision in the ACII model. For Virtuo Vivo, there were no significant differences among the models (<i>p</i> = 0.48). <b>Conclusions:</b> Although intraoral scanners (IOSs) demonstrated significant differences in trueness when used in completely and partially edentulous models with maxillary defects, these differences may be considered clinically insignificant.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"14 21","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545352/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics14212368","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Advances in digital technology and intraoral scanners (IOSs) have the potential to enable accurate digital impressions for patients with maxillary defects. This study aimed to compare the accuracy of IOSs in completely and partially edentulous models with maxillary defects. Methods: Three polyurethane models-one completely edentulous (CE) and two partially edentulous, following Aramany classifications I (ACI) and II (ACII)-were created using stereolithography. These models were scanned with a desktop scanner to create reference models. Ten scans were performed using three different intraoral scanners (TRIOS 3, Primescan, and Virtuo Vivo). The IOS datasets were analyzed to assess trueness and precision using a two-way ANOVA and multiple-comparison tests with Bonferroni corrections (α = 0.05). Results: Both the model type and the IOS significantly influenced trueness and precision. The interaction between the model type and the IOS was found to be statistically significant (trueness: p = 0.001; precision: p = 0.005). The highest trueness was observed in the ACII model scanned with TRIOS 3 and Primescan. TRIOS 3 and Primescan also exhibited the highest precision in the ACII model. For Virtuo Vivo, there were no significant differences among the models (p = 0.48). Conclusions: Although intraoral scanners (IOSs) demonstrated significant differences in trueness when used in completely and partially edentulous models with maxillary defects, these differences may be considered clinically insignificant.

口内扫描仪在不同模型变化的上颌骨缺陷中的准确性。
背景:数字技术和口内扫描仪(IOS)的进步有可能使上颌缺损患者获得准确的数字印模。本研究旨在比较上颌缺损的全口无牙和部分无牙模型中 IOS 的准确性。方法:使用立体光刻技术制作了三个聚氨酯模型,一个是完全无牙(CE),两个是部分无牙(按照 Aramany 分级 I (ACI) 和 II (ACII))。使用台式扫描仪对这些模型进行扫描,以创建参考模型。使用三种不同的口内扫描仪(TRIOS 3、Primescan 和 Virtuo Vivo)进行了十次扫描。使用双向方差分析和多重比较检验以及 Bonferroni 校正(α = 0.05)对 IOS 数据集进行分析,以评估真实度和精确度。结果模型类型和 IOS 都对真实度和精确度有显著影响。发现模型类型和 IOS 之间的交互作用具有统计学意义(真实度:p = 0.001;精确度:p = 0.005)。使用 TRIOS 3 和 Primescan 扫描的 ACII 模型的真实度最高。在 ACII 模型中,TRIOS 3 和 Primescan 的精确度也最高。对于 Virtuo Vivo,各模型之间没有显著差异(p = 0.48)。结论:虽然口内扫描仪(IOS)在上颌缺损的全口和部分缺牙模型中显示出显著的真实度差异,但这些差异在临床上可能并不明显。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信