Utilization of preoperative EOS imaging to prevent adverse events following total hip arthroplasty.

Weston Buehring, Alana Prinos, Akram A Habibi, Morteza Meftah, Matthew Hepinstall, Ran Schwarzkopf
{"title":"Utilization of preoperative EOS imaging to prevent adverse events following total hip arthroplasty.","authors":"Weston Buehring, Alana Prinos, Akram A Habibi, Morteza Meftah, Matthew Hepinstall, Ran Schwarzkopf","doi":"10.1080/17434440.2024.2426472","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Previous studies have demonstrated the use of technology in total hip arthroplasty (THA) provided favorable outcomes. This study sought to describe the effect preoperative two-dimensional low-dose (2DLD) full-body radiographs had on the prevention of adverse outcomes following THA.</p><p><strong>Methods: </strong>We reviewed 11,814 cases of patients who underwent primary, elective THA from 2016 to 2021. Patient demographics and clinical data were compared between patients who did or did not have preoperative standing and sitting 2DLD images (29.5% vs. 70.5%, respectively) using Chi-squared test and multivariate logistic regressions.</p><p><strong>Results: </strong>The rate of patients with preexisting spinal fusion was higher in the 2DLD cohort (2.2 vs. 0.6%, respectively, <i>p</i> < 0.001). Preoperative 2DLD images were favored in outcomes including length of stay (40.15 vs. 67.16 hours; <i>p</i> < 0.001), rate of discharge to home (94.1 vs. 80.0%; <i>p</i> < 0.001), and 90-day readmission rate (3.5 vs. 6.0%; <i>p</i> < 0.001). Multivariate analysis demonstrated preoperative 2DLD images to be significantly associated with lower odds of dislocation, independent from surgical approach, coexisting spinal fusion, and utilization of dual-mobility implants.</p><p><strong>Conclusion: </strong>Preoperative 2DLD images were independently associated with decreased risk for dislocations. Even in a higher risk cohort with spinal fusion, the rate of dislocation in the 2DLD cohort was significantly lower.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2024.2426472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Previous studies have demonstrated the use of technology in total hip arthroplasty (THA) provided favorable outcomes. This study sought to describe the effect preoperative two-dimensional low-dose (2DLD) full-body radiographs had on the prevention of adverse outcomes following THA.

Methods: We reviewed 11,814 cases of patients who underwent primary, elective THA from 2016 to 2021. Patient demographics and clinical data were compared between patients who did or did not have preoperative standing and sitting 2DLD images (29.5% vs. 70.5%, respectively) using Chi-squared test and multivariate logistic regressions.

Results: The rate of patients with preexisting spinal fusion was higher in the 2DLD cohort (2.2 vs. 0.6%, respectively, p < 0.001). Preoperative 2DLD images were favored in outcomes including length of stay (40.15 vs. 67.16 hours; p < 0.001), rate of discharge to home (94.1 vs. 80.0%; p < 0.001), and 90-day readmission rate (3.5 vs. 6.0%; p < 0.001). Multivariate analysis demonstrated preoperative 2DLD images to be significantly associated with lower odds of dislocation, independent from surgical approach, coexisting spinal fusion, and utilization of dual-mobility implants.

Conclusion: Preoperative 2DLD images were independently associated with decreased risk for dislocations. Even in a higher risk cohort with spinal fusion, the rate of dislocation in the 2DLD cohort was significantly lower.

利用术前 EOS 成像预防全髋关节置换术后的不良事件。
导言:以往的研究表明,在全髋关节置换术(THA)中使用技术可带来良好的效果。本研究试图描述术前二维低剂量(2DLD)全身X光片对预防THA术后不良后果的影响:我们回顾了 2016 年至 2021 年期间 11,814 例接受初级、择期 THA 的患者。采用Chi-squared检验和多变量逻辑回归对术前有或没有站立和坐位2DLD影像(分别为29.5% vs. 70.5%)的患者的人口统计学和临床数据进行了比较:结果:2DLD队列中已有脊柱融合的患者比例更高(分别为2.2%和0.6%):术前 2DLD 图像与脱位风险的降低密切相关。即使在脊柱融合的高风险人群中,2DLD人群的脱位率也明显较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信