{"title":"Potentially Inappropriate Cardioverter Defibrillator Implants in Secondary Prevention of Death.","authors":"William Neves de Carvalho, Tainá Teixeira Viana, Clara Salles Figueiredo, Fernanda Martins, Luiz Carlos Santana Passos","doi":"10.36660/abc.20220899","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Implantable cardioverter defibrillators (ICDs) are recommended for patients experiencing malignant tachyarrhythmias due to irreversible causes, who are clinically stable, and have a life expectancy exceeding one year. However, adverse socioeconomic and psychosocial conditions can adversely affect short-term survival and may render implantation inappropriate.</p><p><strong>Objective: </strong>To assess whether economic and psychosocial markers (EPSM) are associated with higher mortality in the first year (indicating potentially inappropriate implants) following ICD implantation.</p><p><strong>Methods: </strong>A prospective cohort study conducted between 2017 and 2021 included patients with heart failure and left ventricular ejection fraction (LVEF) < 50% who underwent ICD implantation for secondary prophylaxis. Prior to the procedure, patients were evaluated by an MDT, which examined four EPSM variables, namely socioeconomic vulnerability, self-care capacity, pharmacological adherence, and mood disorders. The participants were monitored for at least 12 months. Statistical significance was considered to be p-values < 0.05.</p><p><strong>Results: </strong>A total of 208 individuals were included, with 144 (68.9%) being male. The mean LVEF was 32% ±9 and 107 (51%) had Chagas disease etiology. The mortality rate in the first year was 54/208 (25.8%). All patients who died had at least one of the EPSM and there no deaths were reported among the 73 (35.4%) who did not have EPSM. In multivariate analysis, having EPSM and LVEF were the only independent predictors of mortality under 1 year: RR 20.48 (2.75 - 52.29); p=0.003 and RR 0.97 (0.93 - 0.99); p=0.047, respectively.</p><p><strong>Conclusion: </strong>Socioeconomic and psychosocial conditions should be identified and, where possible, resolved before implantation, as they may make device implantation a potentially inappropriate procedure.</p>","PeriodicalId":93887,"journal":{"name":"Arquivos brasileiros de cardiologia","volume":"121 10","pages":"e20220899"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arquivos brasileiros de cardiologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36660/abc.20220899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Implantable cardioverter defibrillators (ICDs) are recommended for patients experiencing malignant tachyarrhythmias due to irreversible causes, who are clinically stable, and have a life expectancy exceeding one year. However, adverse socioeconomic and psychosocial conditions can adversely affect short-term survival and may render implantation inappropriate.

Objective: To assess whether economic and psychosocial markers (EPSM) are associated with higher mortality in the first year (indicating potentially inappropriate implants) following ICD implantation.

Methods: A prospective cohort study conducted between 2017 and 2021 included patients with heart failure and left ventricular ejection fraction (LVEF) < 50% who underwent ICD implantation for secondary prophylaxis. Prior to the procedure, patients were evaluated by an MDT, which examined four EPSM variables, namely socioeconomic vulnerability, self-care capacity, pharmacological adherence, and mood disorders. The participants were monitored for at least 12 months. Statistical significance was considered to be p-values < 0.05.

Results: A total of 208 individuals were included, with 144 (68.9%) being male. The mean LVEF was 32% ±9 and 107 (51%) had Chagas disease etiology. The mortality rate in the first year was 54/208 (25.8%). All patients who died had at least one of the EPSM and there no deaths were reported among the 73 (35.4%) who did not have EPSM. In multivariate analysis, having EPSM and LVEF were the only independent predictors of mortality under 1 year: RR 20.48 (2.75 - 52.29); p=0.003 and RR 0.97 (0.93 - 0.99); p=0.047, respectively.

Conclusion: Socioeconomic and psychosocial conditions should be identified and, where possible, resolved before implantation, as they may make device implantation a potentially inappropriate procedure.

在死亡二级预防中植入潜在不当的心律转复除颤器。
背景:对于因不可逆转的原因导致恶性快速性心律失常、临床病情稳定且预期寿命超过一年的患者,建议使用植入式心律转复除颤器(ICD)。然而,不利的社会经济和社会心理条件会对短期生存产生不利影响,并可能导致不适宜植入:评估经济和社会心理指标(EPSM)是否与 ICD 植入术后第一年较高的死亡率相关(表明可能不适合植入):2017年至2021年间进行的一项前瞻性队列研究纳入了心力衰竭且左室射血分数(LVEF)<50%的患者,这些患者接受了ICD植入术以进行二级预防。手术前,患者接受了MDT评估,该评估检查了四个EPSM变量,即社会经济脆弱性、自理能力、药物依从性和情绪障碍。对参与者进行了至少 12 个月的监测。统计意义以 P 值小于 0.05 为准:共纳入 208 人,其中男性 144 人(68.9%)。平均 LVEF 为 32% ±9,107 人(51%)患有恰加斯病。第一年的死亡率为 54/208(25.8%)。所有死亡患者至少患有一种 EPSM,73 例(35.4%)未患 EPSM 的患者没有死亡报告。在多变量分析中,EPSM和LVEF是预测1年内死亡率的唯一独立因素:分别为 RR 20.48 (2.75 - 52.29); p=0.003 和 RR 0.97 (0.93 - 0.99); p=0.047:社会经济和社会心理状况应在植入前加以识别,并尽可能在植入前解决,因为这些状况可能会使装置植入成为不恰当的手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信