{"title":"Fractal dimension, lacunarity, and bone area fraction analysis of peri-implant trabecular bone after prosthodontic loading.","authors":"Nesrin Dundar, Elif Aslan, Onur Mutlu","doi":"10.1007/s11282-024-00784-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To assess the structural alterations in peri-implant bone occurring 5 years after prosthodontic loading in panoramic radiography (PR).</p><p><strong>Methods: </strong>PR images of 44 mandibular and 33 maxillary implants along with 42 healthy control teeth taken before and 5 years after prosthodontic loading were included. Two regions-of-interest (ROI) were selected from mesial and distal surrounding bone of each implant and tooth. Then, the selected ROIs were divided to obtain three sub-ROIs (coronal, middle, and apical) on each side. A total of eight ROIs and sub-ROIs from each implant and control tooth were used for the calculations of fractal dimension (FD), lacunarity, and bone area fraction (BA/TA). The paired-sample t test was used to compare measurements before and 5 years after loading (p = 0.05).</p><p><strong>Results: </strong>Overall evaluation of 77 implants showed that FD decreased at the middle and apical peri-implant bone levels 5 years after loading (p < 0.05). In mandibular implants, BA/TA decreased after loading (p < 0.05). While FD decreased at the coronal level (p = 0.022), lacunarity increased at the middle level of mandibular implants (p < 0.05). In maxillary implants, FD decreased at the middle and BA/TA decreased at the coronal level (p < 0.05). On the other hand, BA/TA increased at the apical level of maxillary implants (p = 0.016) after loading. None of the parameters revealed any difference in the control group (p > 0.05).</p><p><strong>Conclusions: </strong>FD and BA/TA can be used to analyze structural changes in peri-implant bone after prosthodontic loading. Additionally, FD, lacunarity and BA/TA may provide useful information about changes occurring at different levels of peri-implant bone.</p>","PeriodicalId":56103,"journal":{"name":"Oral Radiology","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11282-024-00784-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To assess the structural alterations in peri-implant bone occurring 5 years after prosthodontic loading in panoramic radiography (PR).
Methods: PR images of 44 mandibular and 33 maxillary implants along with 42 healthy control teeth taken before and 5 years after prosthodontic loading were included. Two regions-of-interest (ROI) were selected from mesial and distal surrounding bone of each implant and tooth. Then, the selected ROIs were divided to obtain three sub-ROIs (coronal, middle, and apical) on each side. A total of eight ROIs and sub-ROIs from each implant and control tooth were used for the calculations of fractal dimension (FD), lacunarity, and bone area fraction (BA/TA). The paired-sample t test was used to compare measurements before and 5 years after loading (p = 0.05).
Results: Overall evaluation of 77 implants showed that FD decreased at the middle and apical peri-implant bone levels 5 years after loading (p < 0.05). In mandibular implants, BA/TA decreased after loading (p < 0.05). While FD decreased at the coronal level (p = 0.022), lacunarity increased at the middle level of mandibular implants (p < 0.05). In maxillary implants, FD decreased at the middle and BA/TA decreased at the coronal level (p < 0.05). On the other hand, BA/TA increased at the apical level of maxillary implants (p = 0.016) after loading. None of the parameters revealed any difference in the control group (p > 0.05).
Conclusions: FD and BA/TA can be used to analyze structural changes in peri-implant bone after prosthodontic loading. Additionally, FD, lacunarity and BA/TA may provide useful information about changes occurring at different levels of peri-implant bone.
期刊介绍:
As the official English-language journal of the Japanese Society for Oral and Maxillofacial Radiology and the Asian Academy of Oral and Maxillofacial Radiology, Oral Radiology is intended to be a forum for international collaboration in head and neck diagnostic imaging and all related fields. Oral Radiology features cutting-edge research papers, review articles, case reports, and technical notes from both the clinical and experimental fields. As membership in the Society is not a prerequisite, contributions are welcome from researchers and clinicians worldwide.