Effect of Repeated Firings on Color Stability of Zirconia- Reinforced Lithium Silicate and Lithium Disilicate Ceramics.

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
M Habibkhodaei, R Mosharraf, O Savabi, F Salehi Ghalesefid
{"title":"Effect of Repeated Firings on Color Stability of Zirconia- Reinforced Lithium Silicate and Lithium Disilicate Ceramics.","authors":"M Habibkhodaei, R Mosharraf, O Savabi, F Salehi Ghalesefid","doi":"10.1922/EJPRD_2466Habibkhodaei07","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this invitro study was to assess the changes in the color attributes of high-translucency (HT) lithium disilicate and zirconia-reinforced lithium silicate in BL3/0M1, A1, A2, and A3 shades during first, second, and third firing cycles.</p><p><strong>Materials and methods: </strong>Eighty specimens of two ceramic systems (IPS e.max CAD and Vita Suprinity) in BL3/0M1, A1, A2, and A3 shades, were prepared in thickness of 1 mm (n=10). Each group was subjected to 3 firing cycles and the CIE L*a*b* color parameters of specimens were measured after each firing cycle by a reflectance spectrophotometer. The color change (ΔE) between each two firing cycles was calculated by the relevant equation. Data were analyzed by one-way ANOVA and Tamhane post hoc test.</p><p><strong>Results: </strong>All ΔE values were significant (P⟨0.001) except for ΔE2-1 (color difference between second and first firing) and ΔE3-2 (color difference between third and second firing) in A2 shade of IPS e.max (P=0.436) and ΔE2-1 and ΔE3-2 in 0M1 shade of Suprinity (P=0.345).</p><p><strong>Conclusion: </strong>Repeated firing resulted in generally higher ΔE in ZLS than LDS, and 0M1 Suprinity experienced maximum ΔE after repeating firing.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2466Habibkhodaei07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this invitro study was to assess the changes in the color attributes of high-translucency (HT) lithium disilicate and zirconia-reinforced lithium silicate in BL3/0M1, A1, A2, and A3 shades during first, second, and third firing cycles.

Materials and methods: Eighty specimens of two ceramic systems (IPS e.max CAD and Vita Suprinity) in BL3/0M1, A1, A2, and A3 shades, were prepared in thickness of 1 mm (n=10). Each group was subjected to 3 firing cycles and the CIE L*a*b* color parameters of specimens were measured after each firing cycle by a reflectance spectrophotometer. The color change (ΔE) between each two firing cycles was calculated by the relevant equation. Data were analyzed by one-way ANOVA and Tamhane post hoc test.

Results: All ΔE values were significant (P⟨0.001) except for ΔE2-1 (color difference between second and first firing) and ΔE3-2 (color difference between third and second firing) in A2 shade of IPS e.max (P=0.436) and ΔE2-1 and ΔE3-2 in 0M1 shade of Suprinity (P=0.345).

Conclusion: Repeated firing resulted in generally higher ΔE in ZLS than LDS, and 0M1 Suprinity experienced maximum ΔE after repeating firing.

反复烧结对氧化锆增强型硅酸锂和二硅酸锂陶瓷颜色稳定性的影响
目的:这项体外研究的目的是评估BL3/0M1、A1、A2和A3色调的高透明度(HT)二硅酸锂和氧化锆增强硅酸锂在第一、第二和第三烧结周期中颜色属性的变化:制备了两种陶瓷系统(IPS e.max CAD 和 Vita Suprinity)的 80 个试样,色调分别为 BL3/0M1、A1、A2 和 A3,厚度均为 1 毫米(n=10)。每组试样经过 3 个烧制周期,每个烧制周期结束后用反射分光光度计测量试样的 CIE L*a*b* 颜色参数。每两个焙烧周期之间的颜色变化(ΔE)由相关公式计算得出。数据分析采用单因素方差分析和 Tamhane 后检验:除了 IPS e.max 的 A2 色调中的ΔE2-1(第二次与第一次焙烧之间的色差)和ΔE3-2(第三次与第二次焙烧之间的色差)(P=0.436)以及 Suprinity 的 0M1 色调中的ΔE2-1 和 ΔE3-2(P=0.345)之外,所有的ΔE 值都具有显著性(P⟨0.001):重复焙烧导致 ZLS 的 ΔE 普遍高于 LDS,0M1 Suprinity 在重复焙烧后出现最大 ΔE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信