{"title":"Determination of vitamin D<sub>3</sub> content in cod liver oil using column-switching technique.","authors":"Lyuye Qi, Liyuan Zhang, Qiaoyuan Cheng, Linqi Yan, Minghao Zhou","doi":"10.3724/zdxbyxb-2024-0045","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To develop a two-dimensional liquid chromatography method to determine the content of vitamin D<sub>3</sub> in cod liver oil preparations.</p><p><strong>Methods: </strong>The samples were prepared by saponification and extraction, and the content of vitamin D<sub>3</sub> was determined by two-dimensional liquid chromatography with dual-pump-single-valve switching dual detectors. The chromatographic column, capture device, and detection wavelength were optimized; the linearity, system suitability, recovery rate, repeatability and sample stability of the method were investigated, and further validated in actual sample determination.</p><p><strong>Results: </strong>A column switching two-dimensional chromatography method was developed. In the first dimensional chromatography, an Agilent PoroShell SB-C8 (50 mm×4.6 mm, 2.7 μm) column was used, and acetonitrile-water was used as mobile phase and gradiently eluted at a flow rate of 1.0 mL/min, the detection wavelength was 264 nm. An Agilent Zorbax SB-C18 (150 mm×3.0 mm,1.8 μm) column was used in the second dimensional chromatography, and acetonitrile was used as mobile phase at a flow rate of 0.42 mL/min, the detection wavelength was 264 nm. In determining content of Vitamin D<sub>3</sub>, there was a good linear relationship in the concentration range and the system suitability, recovery rate, repeatability and sample stability all met the verification requirements.</p><p><strong>Conclusions: </strong>The developed two-dimensional liquid chromatography method in the study is accurate, reproducible and simple, it can simultaneously separate pre-vitamin D<sub>3</sub>, trans-vitamin D<sub>3</sub>, vitamin D<sub>3</sub>, and tachysterol3, the baseline separation was achieved, indicating that it is worth promoting for application.</p>","PeriodicalId":24007,"journal":{"name":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/zdxbyxb-2024-0045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To develop a two-dimensional liquid chromatography method to determine the content of vitamin D3 in cod liver oil preparations.
Methods: The samples were prepared by saponification and extraction, and the content of vitamin D3 was determined by two-dimensional liquid chromatography with dual-pump-single-valve switching dual detectors. The chromatographic column, capture device, and detection wavelength were optimized; the linearity, system suitability, recovery rate, repeatability and sample stability of the method were investigated, and further validated in actual sample determination.
Results: A column switching two-dimensional chromatography method was developed. In the first dimensional chromatography, an Agilent PoroShell SB-C8 (50 mm×4.6 mm, 2.7 μm) column was used, and acetonitrile-water was used as mobile phase and gradiently eluted at a flow rate of 1.0 mL/min, the detection wavelength was 264 nm. An Agilent Zorbax SB-C18 (150 mm×3.0 mm,1.8 μm) column was used in the second dimensional chromatography, and acetonitrile was used as mobile phase at a flow rate of 0.42 mL/min, the detection wavelength was 264 nm. In determining content of Vitamin D3, there was a good linear relationship in the concentration range and the system suitability, recovery rate, repeatability and sample stability all met the verification requirements.
Conclusions: The developed two-dimensional liquid chromatography method in the study is accurate, reproducible and simple, it can simultaneously separate pre-vitamin D3, trans-vitamin D3, vitamin D3, and tachysterol3, the baseline separation was achieved, indicating that it is worth promoting for application.