{"title":"[Anatomical research of positional relationship between protective channel and sural nerve during Achilles tendon repair using channel assisted minimally invasive repair technique].","authors":"Zhonghe Wang, Wenhao Cao, Hongzhe Qi, Lingtong Kong, Haoyu Liu, Chen Chen, Lianhua Li, Lijun Sun, Hua Chen","doi":"10.7507/1002-1892.202408055","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the positional relationship between protective channel and sural nerve while treating acute Achilles tendon rupture with channel assisted minimally invasive repair (CAMIR) technique based on anatomical observations of cadaver specimens.</p><p><strong>Methods: </strong>Twelve adult cadaveric lower limb specimens (6 left, 6 right) were utilized. A CAMIR device was implanted at a distance of 4 cm from the proximal end of the specimen to the Achilles tendon insertion. The skin was incised along the tendon's medial side, the sural nerve was dissected, and the positional relationship with the protective channel was observed. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion, the vertical distance between protective channel and the calcaneal insertion, and the horizontal distance between the sural nerve and protective channel were measured by using vernier caliper.</p><p><strong>Results: </strong>Anatomical examination demonstrated a variable positional relationship between the sural nerve and protective channel, with the sural nerve positioned above (8 specimens) or below (4 specimens) the protective channel. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion was (105.67±14.94) mm, the vertical distance between protective channel and the calcaneal insertion was (93.20±9.57) mm, and the horizontal distance between the sural nerve and protective channel was (0.31±0.14) mm.</p><p><strong>Conclusion: </strong>The use of CAMIR technique for the treatment of acute Achilles tendon rupture can effectively avoid iatrogenic injury to the sural nerve.</p>","PeriodicalId":23979,"journal":{"name":"中国修复重建外科杂志","volume":"38 11","pages":"1325-1329"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563749/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国修复重建外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7507/1002-1892.202408055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the positional relationship between protective channel and sural nerve while treating acute Achilles tendon rupture with channel assisted minimally invasive repair (CAMIR) technique based on anatomical observations of cadaver specimens.

Methods: Twelve adult cadaveric lower limb specimens (6 left, 6 right) were utilized. A CAMIR device was implanted at a distance of 4 cm from the proximal end of the specimen to the Achilles tendon insertion. The skin was incised along the tendon's medial side, the sural nerve was dissected, and the positional relationship with the protective channel was observed. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion, the vertical distance between protective channel and the calcaneal insertion, and the horizontal distance between the sural nerve and protective channel were measured by using vernier caliper.

Results: Anatomical examination demonstrated a variable positional relationship between the sural nerve and protective channel, with the sural nerve positioned above (8 specimens) or below (4 specimens) the protective channel. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion was (105.67±14.94) mm, the vertical distance between protective channel and the calcaneal insertion was (93.20±9.57) mm, and the horizontal distance between the sural nerve and protective channel was (0.31±0.14) mm.

Conclusion: The use of CAMIR technique for the treatment of acute Achilles tendon rupture can effectively avoid iatrogenic injury to the sural nerve.

[利用通道辅助微创修复技术修复跟腱时保护性通道与韧带神经位置关系的解剖学研究]。
目的根据对尸体标本的解剖观察,评估在使用通道辅助微创修复(CAMIR)技术治疗急性跟腱断裂时,保护性通道与鞍神经之间的位置关系:方法:利用 12 个成人尸体下肢标本(左侧 6 个,右侧 6 个)。从标本近端到跟腱插入处 4 厘米处植入一个 CAMIR 装置。沿肌腱内侧切开皮肤,解剖硬神经,观察其与保护通道的位置关系。使用游标卡尺测量了腓肠神经-跟腱交叉点到小腿内侧插入点的距离、保护性通道和小腿内侧插入点之间的垂直距离以及腓肠神经和保护性通道之间的水平距离:解剖学检查显示,腓肠神经和保护性通道之间的位置关系各不相同,腓肠神经位于保护性通道上方(8 例标本)或下方(4 例标本)。硬神经-跟腱交点到小腿内侧的距离为(105.67±14.94)毫米,保护性通道和小腿内侧之间的垂直距离为(93.20±9.57)毫米,硬神经和保护性通道之间的水平距离为(0.31±0.14)毫米:结论:使用 CAMIR 技术治疗急性跟腱断裂可有效避免对硬脊膜神经的先天性损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
中国修复重建外科杂志
中国修复重建外科杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
11334
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信