Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes.

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Efekan Coskunseven, Belma Kayhan
{"title":"Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes.","authors":"Efekan Coskunseven, Belma Kayhan","doi":"10.3928/1081597X-20240913-03","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the reasons for the removal and/or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures.</p><p><strong>Methods: </strong>In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations.</p><p><strong>Results: </strong>Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (<i>P</i> < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL.</p><p><strong>Conclusions: </strong>The main reason for PCPIOL removal and/or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed. <b>[<i>J Refract Surg</i>. 2024;40(11):e797-e803.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 11","pages":"e797-e803"},"PeriodicalIF":2.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240913-03","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the reasons for the removal and/or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures.

Methods: In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations.

Results: Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (P < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL.

Conclusions: The main reason for PCPIOL removal and/or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed. [J Refract Surg. 2024;40(11):e797-e803.].

1,490 只眼睛的后房型法康眼内透镜爆裂原因。
目的:调查摘除和/或更换后房型人工晶体(PCPIOL)的原因以及这些手术的结果:在这项回顾性研究中,研究人员回顾了 2015 年 1 月至 2023 年 6 月期间在一个中心进行的 PCPIOL 植入手术。研究组包括摘除和/或交换 PCPIOL 的眼球档案。记录了更换前后的视力、屈光误差、内皮细胞计数和穹隆测量结果。对摘除和/或更换的原因进行了评估。所有摘除手术均采用掖拉技术:结果:在 1490 只植入 PCPIOL 的眼睛中,有 23 只需要摘除和/或更换。在取出的眼球中,17 只植入了用于近视矫正的 PCPIOL(占所有近视矫正眼球的 1.21%),6 只植入了用于远视矫正的 PCPIOL(占所有远视矫正眼球的 6.59%)。植入后最常见的摘除和/或更换原因是穹窿不合适(23 例摘除和/或更换中的 10 例),其次是白内障发展(23 例摘除和/或更换中的 7 例)。将因穹窿不合适而摘除和/或更换 PCPIOL 的眼球与其他植入 PCPIOL 的眼球的生物测量特征进行比较后发现,前房深度、PCPIOL 长度和白内障到白内障的距离在被摘除眼球组中明显更高(P < .05)。所有近视患者的高穹隆眼都植入了 13.2 或 13.7 毫米长的 PCPIOL:结论:摘除和/或更换 PCPIOL 的主要原因是穹窿值超出理想范围和白内障发展。在订购 13.2 毫米和 13.7 毫米长的 PCPIOL 之前,应仔细审查双眼的生物测量数据和推荐的 PCPIOL 尺寸。[J Refract Surg. 2024;40(11):e797-e803]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信