Efficacy and Safety of Aurolab Aqueous Drainage Implant Compared With Baerveldt Glaucoma Implant for Refractory Glaucoma at One Year: A Systematic Review and Meta-Analysis.

IF 1.8 4区 医学 Q3 OPHTHALMOLOGY
Journal of Ophthalmology Pub Date : 2024-11-01 eCollection Date: 2024-01-01 DOI:10.1155/2024/8617959
Sandesh Raja, Umer Nisar, Owais Khan, Riteeka Kumari Bhimani, Adarsh Raja, Aayush Chaulagain
{"title":"Efficacy and Safety of Aurolab Aqueous Drainage Implant Compared With Baerveldt Glaucoma Implant for Refractory Glaucoma at One Year: A Systematic Review and Meta-Analysis.","authors":"Sandesh Raja, Umer Nisar, Owais Khan, Riteeka Kumari Bhimani, Adarsh Raja, Aayush Chaulagain","doi":"10.1155/2024/8617959","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Glaucoma stands as a prominent contributor to irreversible vision impairment on a global scale. For decades, the Baerveldt Glaucoma Implant (BGI) has been used to treat refractory glaucoma. Yet, the cost-effective Aurolab Aqueous Drainage Implant (AADI) has gained clinical attention as a viable alternative for managing glaucoma. <b>Objective:</b> The purpose of this study was to evaluate and compare the efficacy and safety of AADI and BGI in the treatment of refractory glaucoma. <b>Methods:</b> Following PRISMA guidelines, we conducted a systematic search of multiple databases, identifying relevant comparative studies assessing AADI versus BGI in patients with refractory glaucoma. Key outcomes included postoperative IOP, surgical success rates, antiglaucoma medication reduction (AGMR), and complication rates. Quality assessment was performed using the Newcastle-Ottawa Scale (NOS). <b>Results:</b> Three studies comprised a total of 176 individuals with refractory glaucoma, with 107 patients receiving the AADI and 69 patients receiving the BGI. The meta-analysis revealed a statistically borderline significant reduction in postoperative IOP favoring the AADI at 3 months (mean difference [MD] = -2.74, <i>p</i>=0.05). There was no significant difference in the MD of AGMR between the AADI and BGI groups. The rates of total complications and surgical success did not differ significantly between the AADI and BGI groups. <b>Conclusion:</b> AADI demonstrates promising results in reducing IOP at 3 months compared to BGI, with comparable surgical outcomes and complication rates over the long term. Further studies with larger samples are warranted to validate these findings and assess cost-effectiveness, particularly in developing countries.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":"2024 ","pages":"8617959"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548946/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2024/8617959","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Glaucoma stands as a prominent contributor to irreversible vision impairment on a global scale. For decades, the Baerveldt Glaucoma Implant (BGI) has been used to treat refractory glaucoma. Yet, the cost-effective Aurolab Aqueous Drainage Implant (AADI) has gained clinical attention as a viable alternative for managing glaucoma. Objective: The purpose of this study was to evaluate and compare the efficacy and safety of AADI and BGI in the treatment of refractory glaucoma. Methods: Following PRISMA guidelines, we conducted a systematic search of multiple databases, identifying relevant comparative studies assessing AADI versus BGI in patients with refractory glaucoma. Key outcomes included postoperative IOP, surgical success rates, antiglaucoma medication reduction (AGMR), and complication rates. Quality assessment was performed using the Newcastle-Ottawa Scale (NOS). Results: Three studies comprised a total of 176 individuals with refractory glaucoma, with 107 patients receiving the AADI and 69 patients receiving the BGI. The meta-analysis revealed a statistically borderline significant reduction in postoperative IOP favoring the AADI at 3 months (mean difference [MD] = -2.74, p=0.05). There was no significant difference in the MD of AGMR between the AADI and BGI groups. The rates of total complications and surgical success did not differ significantly between the AADI and BGI groups. Conclusion: AADI demonstrates promising results in reducing IOP at 3 months compared to BGI, with comparable surgical outcomes and complication rates over the long term. Further studies with larger samples are warranted to validate these findings and assess cost-effectiveness, particularly in developing countries.

Aurolab 眼液引流植入剂与 Baerveldt 青光眼植入剂治疗难治性青光眼一年后的疗效和安全性比较:系统回顾与元分析》。
背景:在全球范围内,青光眼是造成不可逆视力损伤的主要原因。几十年来,贝氏青光眼植入器(BGI)一直被用于治疗难治性青光眼。然而,作为治疗青光眼的一种可行的替代方法,具有成本效益的 Aurolab 眼液引流植入器(AADI)已受到临床关注。研究目的本研究旨在评估和比较 AADI 和 BGI 治疗难治性青光眼的有效性和安全性。方法: 我们按照 PRISMA 指南进行了研究:按照 PRISMA 指南,我们对多个数据库进行了系统性检索,确定了评估 AADI 与 BGI 在难治性青光眼患者中疗效的相关比较研究。主要结果包括术后眼压、手术成功率、抗青光眼药物减量(AGMR)和并发症发生率。采用纽卡斯尔-渥太华量表(NOS)进行质量评估。结果:三项研究共纳入 176 名难治性青光眼患者,其中 107 名患者接受了 AADI,69 名患者接受了 BGI。荟萃分析显示,术后 3 个月时,AADI 能显著降低术后眼压(平均差 [MD] = -2.74,P=0.05)。AADI 组和 BGI 组的 AGMR 的 MD 无明显差异。总并发症发生率和手术成功率在 AADI 组和 BGI 组之间没有明显差异。结论:与 BGI 相比,AADI 在 3 个月内降低眼压方面显示出良好的效果,长期手术效果和并发症发生率也相当。有必要对更多样本进行进一步研究,以验证这些发现并评估成本效益,尤其是在发展中国家。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信