PhenoMATRIX™ for the screening of Group B Streptococcus (GBS) carriage in pregnant women: ready to get rid of the LIM broth?

IF 3.7 3区 医学 Q2 INFECTIOUS DISEASES
Abdessalam Cherkaoui, Gesuele Renzi, Jacques Schrenzel
{"title":"PhenoMATRIX™ for the screening of Group B Streptococcus (GBS) carriage in pregnant women: ready to get rid of the LIM broth?","authors":"Abdessalam Cherkaoui, Gesuele Renzi, Jacques Schrenzel","doi":"10.1007/s10096-024-04985-7","DOIUrl":null,"url":null,"abstract":"<p><p>There is a constant need to reduce turn-around times and keep costs as low as possible for the carriage screening of GBS in pregnant patients. Laboratory automation might provide an edge in this field. The objectives of the present study were: i) to compare the performance of the direct chromID™ Strepto B agar (CA) plating against LIM-broth enriched plating on CA for the detection of GBS from vagino-rectal screening-swabs; and ii) to assess the usage of PhenoMATRIX™ for the automated screening of GBS. Between January 2021 and December 2023, 9'107 vagino-rectal specimens were collected from pregnant women at Geneva University Hospitals and were used to address the first objective. There was a small difference in the GBS detection rates between direct CA plating (13.2%; 1'202/9'107) and LIM-broth enriched plating on CA (13.2%; 1'198/9'107). Based on the LIM-broth enrichment results, the sensitivity and specificity of the direct CA plating were 98.3% (95% CI, 97.3%-98.9%) and 99.7% (95% CI, 99.5%-99.8%), respectively. Importantly, for 25 specimens, GBS growth was only detected by direct CA plating. We used a random set of 8'768 CA plate pictures for the machine learning of PhenoMATRIX™. The validation was carried out on an additional set of 830 CA plate pictures. The sensitivity and specificity of PhenoMATRIX™ were 100% (95% CI, 96.6%-100.0%) and 90.2% (95% CI, 87.8%-92.1%), respectively. We established that for GBS screening, the performance of direct CA plating is not inferior to the LIM-broth enriched approach. By relying on PhenoMATRIX™, the negative predictive value for GBS screening reaches 100% (95% CI, 99.4%-100.0%), enabling the automatic release of GBS-negative cases within 24 h.</p>","PeriodicalId":11782,"journal":{"name":"European Journal of Clinical Microbiology & Infectious Diseases","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Clinical Microbiology & Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10096-024-04985-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

There is a constant need to reduce turn-around times and keep costs as low as possible for the carriage screening of GBS in pregnant patients. Laboratory automation might provide an edge in this field. The objectives of the present study were: i) to compare the performance of the direct chromID™ Strepto B agar (CA) plating against LIM-broth enriched plating on CA for the detection of GBS from vagino-rectal screening-swabs; and ii) to assess the usage of PhenoMATRIX™ for the automated screening of GBS. Between January 2021 and December 2023, 9'107 vagino-rectal specimens were collected from pregnant women at Geneva University Hospitals and were used to address the first objective. There was a small difference in the GBS detection rates between direct CA plating (13.2%; 1'202/9'107) and LIM-broth enriched plating on CA (13.2%; 1'198/9'107). Based on the LIM-broth enrichment results, the sensitivity and specificity of the direct CA plating were 98.3% (95% CI, 97.3%-98.9%) and 99.7% (95% CI, 99.5%-99.8%), respectively. Importantly, for 25 specimens, GBS growth was only detected by direct CA plating. We used a random set of 8'768 CA plate pictures for the machine learning of PhenoMATRIX™. The validation was carried out on an additional set of 830 CA plate pictures. The sensitivity and specificity of PhenoMATRIX™ were 100% (95% CI, 96.6%-100.0%) and 90.2% (95% CI, 87.8%-92.1%), respectively. We established that for GBS screening, the performance of direct CA plating is not inferior to the LIM-broth enriched approach. By relying on PhenoMATRIX™, the negative predictive value for GBS screening reaches 100% (95% CI, 99.4%-100.0%), enabling the automatic release of GBS-negative cases within 24 h.

用于筛查孕妇乙型链球菌(GBS)携带情况的 PhenoMATRIX™:准备好摆脱 LIM 肉汤的束缚了吗?
在对孕妇进行肠道病毒携带筛查时,需要不断缩短周转时间并尽可能降低成本。实验室自动化可为这一领域提供优势。本研究的目的是:i) 比较直接 chromID™ Strepto B 琼脂 (CA) 镀膜与 LIM-broth 富集镀膜在从阴道直肠筛查拭子中检测 GBS 方面的性能;ii) 评估 PhenoMATRIX™ 在自动筛查 GBS 方面的应用。2021 年 1 月至 2023 年 12 月期间,日内瓦大学医院从孕妇处采集了 9 107 份阴道直肠标本,用于实现第一个目标。CA直接镀膜(13.2%;1'202/9'107)和CA上的LIM-broth富集镀膜(13.2%;1'198/9'107)的GBS检出率差异很小。根据 LIM-菌落富集结果,CA 直接镀膜的敏感性和特异性分别为 98.3% (95% CI, 97.3%-98.9%) 和 99.7% (95% CI, 99.5%-99.8%) 。重要的是,有 25 份标本只能通过直接 CA 镀层检测到 GBS 生长。我们使用一组随机的 8 768 张 CA 平板图片对 PhenoMATRIX™ 进行机器学习。在另外一组 830 张 CA 平板图片上进行了验证。PhenoMATRIX™ 的灵敏度和特异度分别为 100%(95% CI,96.6%-100.0%)和 90.2%(95% CI,87.8%-92.1%)。我们证实,在 GBS 筛查中,直接 CA 镀膜法的效果并不亚于 LIM 盆富集法。依靠 PhenoMATRIX™,GBS 筛查的阴性预测值达到 100%(95% CI,99.4%-100.0%),可在 24 小时内自动发布 GBS 阴性病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.40
自引率
2.20%
发文量
138
审稿时长
1 months
期刊介绍: EJCMID is an interdisciplinary journal devoted to the publication of communications on infectious diseases of bacterial, viral and parasitic origin.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信