Assessment of Microcirculatory Dysfunction by Measuring Subcutaneous Tissue Oxygen Saturation Using Near-Infrared Spectroscopy in Patients with Circulatory Failure.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Jun Sato, Atsushi Sakurai, Shingo Ihara, Katsuhiro Nakagawa, Nobutaka Chiba, Takeshi Saito, Kosaku Kinoshita
{"title":"Assessment of Microcirculatory Dysfunction by Measuring Subcutaneous Tissue Oxygen Saturation Using Near-Infrared Spectroscopy in Patients with Circulatory Failure.","authors":"Jun Sato, Atsushi Sakurai, Shingo Ihara, Katsuhiro Nakagawa, Nobutaka Chiba, Takeshi Saito, Kosaku Kinoshita","doi":"10.3390/diagnostics14212428","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients with circulatory failure have high mortality rates and require prompt assessment of microcirculation. Despite the improvement in hemodynamic parameters, microcirculatory dysfunction persists. We measured subcutaneous regional tissue oxygen saturation (rSO<sub>2</sub>) with near-infrared spectroscopy (NIRS), which can assess microcirculation in patients with circulatory failure.</p><p><strong>Methods: </strong>A finger-worn oximeter with NIRS measured rSO<sub>2</sub> in the forehead, thenar eminence, thumb, and knees. First, the rSO<sub>2</sub> was measured in healthy adult volunteers (<i>n</i> = 10). Circulatory failure was defined as a systolic blood pressure ≤ 90 mmHg and lactate ≥ 2 mmol/L. The study included 35 patients without circulatory failure and SOFA score of 0 at ICU admission and 38 patients with circulatory failure at ICU admission. Both groups included a single-center prospective study of patients who were transported to the ICU of the Nihon University Hospital. The rSO<sub>2</sub> was measured only on ICU admission in the non-circulatory failure group and later in the circulatory failure group.</p><p><strong>Results: </strong>In the volunteer group, rSO<sub>2</sub> at each site was approximately 58%. The rSO<sub>2</sub> was significantly lower in the circulatory failure group than in the non-circulatory failure group (knee, <i>p</i> < 0.01). In the circulatory failure group, knee rSO<sub>2</sub> showed a significant negative correlation with SOFA score (Day 0, ρ = -0.37, <i>p</i> = 0.02; Day 1, ρ = -0.53, <i>p</i> < 0.01; Day 2, ρ = -0.60, <i>p</i> < 0.01).</p><p><strong>Conclusions: </strong>Subcutaneous knee rSO<sub>2</sub> was associated with SOFA score and was considered an indicator of microcirculatory dysfunction and organ damage.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"14 21","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545383/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics14212428","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Patients with circulatory failure have high mortality rates and require prompt assessment of microcirculation. Despite the improvement in hemodynamic parameters, microcirculatory dysfunction persists. We measured subcutaneous regional tissue oxygen saturation (rSO2) with near-infrared spectroscopy (NIRS), which can assess microcirculation in patients with circulatory failure.

Methods: A finger-worn oximeter with NIRS measured rSO2 in the forehead, thenar eminence, thumb, and knees. First, the rSO2 was measured in healthy adult volunteers (n = 10). Circulatory failure was defined as a systolic blood pressure ≤ 90 mmHg and lactate ≥ 2 mmol/L. The study included 35 patients without circulatory failure and SOFA score of 0 at ICU admission and 38 patients with circulatory failure at ICU admission. Both groups included a single-center prospective study of patients who were transported to the ICU of the Nihon University Hospital. The rSO2 was measured only on ICU admission in the non-circulatory failure group and later in the circulatory failure group.

Results: In the volunteer group, rSO2 at each site was approximately 58%. The rSO2 was significantly lower in the circulatory failure group than in the non-circulatory failure group (knee, p < 0.01). In the circulatory failure group, knee rSO2 showed a significant negative correlation with SOFA score (Day 0, ρ = -0.37, p = 0.02; Day 1, ρ = -0.53, p < 0.01; Day 2, ρ = -0.60, p < 0.01).

Conclusions: Subcutaneous knee rSO2 was associated with SOFA score and was considered an indicator of microcirculatory dysfunction and organ damage.

使用近红外光谱法测量循环衰竭患者皮下组织氧饱和度以评估微循环功能障碍
背景:循环衰竭患者的死亡率很高,需要及时对微循环进行评估。尽管血液动力学参数有所改善,但微循环功能障碍依然存在。我们用近红外光谱(NIRS)测量了皮下区域组织氧饱和度(rSO2),它可以评估循环衰竭患者的微循环:方法:使用带有近红外光谱技术的指戴式血氧仪测量前额、耳廓、拇指和膝盖的 rSO2。首先,测量健康成年志愿者(10 人)的 rSO2。循环衰竭的定义是收缩压≤90 mmHg,乳酸≥2 mmol/L。该研究包括 35 名入院时未出现循环衰竭且 SOFA 评分为 0 的患者和 38 名入院时出现循环衰竭的患者。两组患者都是被送往日本大学医院重症监护室的单中心前瞻性研究。非循环衰竭组仅在入ICU时测量rSO2,循环衰竭组则在入ICU后测量rSO2:结果:在志愿者组中,每个部位的 rSO2 约为 58%。循环衰竭组的 rSO2 明显低于非循环衰竭组(膝关节,P < 0.01)。在循环衰竭组,膝关节 rSO2 与 SOFA 评分呈显著负相关(第 0 天,ρ = -0.37,p = 0.02;第 1 天,ρ = -0.53,p < 0.01;第 2 天,ρ = -0.60,p < 0.01):结论:膝关节皮下 rSO2 与 SOFA 评分相关,是微循环功能障碍和器官损伤的指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信