Is the Use of the Extended (Meth)acrylate Series - Nails Justified? Characterization of Nail Acrylate Allergy in a Tertiary Medical Centre.

IF 3.5 4区 医学 Q1 DERMATOLOGY
Joel Dascalu, Sophia Polansky, Ziad Khamaysi, Emily Avitan-Hersh, Mariela J Nevet
{"title":"Is the Use of the Extended (Meth)acrylate Series - Nails Justified? Characterization of Nail Acrylate Allergy in a Tertiary Medical Centre.","authors":"Joel Dascalu, Sophia Polansky, Ziad Khamaysi, Emily Avitan-Hersh, Mariela J Nevet","doi":"10.2340/actadv.v104.41079","DOIUrl":null,"url":null,"abstract":"<p><p>Methacrylate allergy is a common cause of allergic contact dermatitis, and its incidence has surged over the past decade. Consequently, the primary sensitizing agent, 2-hydroxyethyl methacrylate, was recently added to the European Baseline Series of contact allergens. This study aimed to assess the added value of testing for allergens included in the (Meth)Acrylate Series - Nails, in addition to 2-hydroxyethyl methacrylate, as well as to characterize patients who may benefit from more extensive testing. A retrospective analysis of medical records of patch-tested patients was conducted between June 2013 and July 2022. Among the 3,828 patients who underwent patch testing, 396 were tested with the (Meth)Acrylate Series - Nails; 153 (38.6%) of those patients tested positive for at least 1 acrylate. The most common hapten was 2-hydroxyethyl methacrylate (85.6%), followed by hydroxypropyl methacrylate (85.0%) and ethylene glycol dimethacrylate (80.4%). In our study, 22/153 patients (14.4%) would have been missed if tested only for 2-hydroxyethyl methacrylate. The analysis showed that including hydroxypropyl methacrylate and ethylene glycol dimethacrylate improved detection rate to 98%, rendering the use of the entire tray unnecessary in most cases.</p>","PeriodicalId":6944,"journal":{"name":"Acta dermato-venereologica","volume":"104 ","pages":"adv41079"},"PeriodicalIF":3.5000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11571230/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta dermato-venereologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/actadv.v104.41079","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DERMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Methacrylate allergy is a common cause of allergic contact dermatitis, and its incidence has surged over the past decade. Consequently, the primary sensitizing agent, 2-hydroxyethyl methacrylate, was recently added to the European Baseline Series of contact allergens. This study aimed to assess the added value of testing for allergens included in the (Meth)Acrylate Series - Nails, in addition to 2-hydroxyethyl methacrylate, as well as to characterize patients who may benefit from more extensive testing. A retrospective analysis of medical records of patch-tested patients was conducted between June 2013 and July 2022. Among the 3,828 patients who underwent patch testing, 396 were tested with the (Meth)Acrylate Series - Nails; 153 (38.6%) of those patients tested positive for at least 1 acrylate. The most common hapten was 2-hydroxyethyl methacrylate (85.6%), followed by hydroxypropyl methacrylate (85.0%) and ethylene glycol dimethacrylate (80.4%). In our study, 22/153 patients (14.4%) would have been missed if tested only for 2-hydroxyethyl methacrylate. The analysis showed that including hydroxypropyl methacrylate and ethylene glycol dimethacrylate improved detection rate to 98%, rendering the use of the entire tray unnecessary in most cases.

使用丙烯酸(甲基)酯扩展系列--指甲是否合理?一家三级医疗中心的丙烯酸甲酯过敏症特征。
甲基丙烯酸酯过敏是导致过敏性接触性皮炎的常见原因,其发病率在过去十年中急剧上升。因此,2-羟乙基甲基丙烯酸酯这种主要致敏物质最近被列入了欧洲接触性过敏原基线系列。本研究旨在评估除甲基丙烯酸 2-羟乙基酯外,检测《(甲基)丙烯酸酯系列-指甲》中过敏原的附加价值,以及可能受益于更广泛检测的患者的特征。我们在 2013 年 6 月至 2022 年 7 月期间对接受贴片测试的患者病历进行了回顾性分析。在接受贴片检测的3828名患者中,有396人接受了(甲基)丙烯酸酯系列--指甲的检测;其中153人(38.6%)至少对一种丙烯酸酯检测呈阳性。最常见的单体是甲基丙烯酸羟乙酯(85.6%),其次是甲基丙烯酸羟丙酯(85.0%)和乙二醇二甲基丙烯酸酯(80.4%)。在我们的研究中,如果只检测甲基丙烯酸羟乙酯,22/153 名患者(14.4%)会被漏检。分析表明,将甲基丙烯酸羟丙酯和乙二醇二甲基丙烯酸酯包括在内可将检出率提高到 98%,从而在大多数情况下无需使用整个托盘。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta dermato-venereologica
Acta dermato-venereologica 医学-皮肤病学
CiteScore
4.90
自引率
2.80%
发文量
210
审稿时长
6-12 weeks
期刊介绍: Acta Dermato-Venereologica publishes high-quality manuscripts in English in the field of Dermatology and Venereology, dealing with new observations on basic dermatological and venereological research, as well as clinical investigations. Each volume also features a number of Review articles in special areas, as well as short Letters to the Editor to stimulate debate and to disseminate important clinical observations. Acta Dermato-Venereologica has rapid publication times and is amply illustrated with a large number of colour photographs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信