Effect of office-based vergence and anti-suppression therapy on binocular vision and accommodation in small-to-moderate angle intermittent exotropia: A randomised clinical trial.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Martin Ming-Leung Ma, Ying Kang, Mitchell Scheiman, Qiwen Chen, Xuelian Ye, Liuqing Pan, Jiayu Deng, Guangxing Su, Guohui Zhang, Xiang Chen
{"title":"Effect of office-based vergence and anti-suppression therapy on binocular vision and accommodation in small-to-moderate angle intermittent exotropia: A randomised clinical trial.","authors":"Martin Ming-Leung Ma, Ying Kang, Mitchell Scheiman, Qiwen Chen, Xuelian Ye, Liuqing Pan, Jiayu Deng, Guangxing Su, Guohui Zhang, Xiang Chen","doi":"10.1111/opo.13415","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the short-term (1 week after completion of treatment) effect of office-based vergence and anti-suppression therapy (OBVAT) on binocular vision and accommodative function when compared to observation alone in children with small-to-moderate angle intermittent exotropia (IXT).</p><p><strong>Methods: </strong>In this single-masked (examiner masked), two-arm, single-centre randomised clinical trial, 40 participants, 6 to <18 years of age with untreated IXT were randomly assigned to OBVAT or observation alone. Participants assigned to therapy received 16 weeks of OBVAT (60 min per visit, once per week) with home reinforcement (15 min per day, 5 days a week). Therapy included vergence, accommodation and anti-suppression techniques. This paper reports the results of clinical measures of binocular vision and accommodation, including fusional vergence, near point of convergence, vergence facility, amplitude of accommodation, the Worth 4-dot test and the Fusion Maintenance Score (FMS).</p><p><strong>Results: </strong>Treatment group differences at the primary outcome visit significantly favoured the OBVAT group (n = 20) over the observation group (n = 16) in negative fusional vergence break point at both distance (p ≤ 0.001; r = 0.58) and near (adjusted mean difference: 12.3 Δ; 95% CI: 5.3-19.3 Δ; p = 0.001; partial eta squared: 0.28), positive fusional vergence break point at both distance (p = 0.009; r = 0.43) and near (adjusted mean difference: 20.6 Δ; 95% CI: 11.8-29.4 Δ; p ≤ 0.001; partial eta squared: 0.41), vergence facility (adjusted mean difference: 5.6 cpm; 95% CI: 1.9-9.4 cpm; p = 0.005; partial eta squared: 0.22) and the FMS (p = 0.007; r = 0.44).</p><p><strong>Conclusions: </strong>In this randomised clinical trial of participants aged 6 to <18 years with IXT, those in the OBVAT group had a significantly better fusional vergence range, vergence facility, near Worth 4-dot test result and FMS than the observation group at the 17-week visit. The improvement in these areas further support the effectiveness of OBVAT for improving IXT.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13415","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the short-term (1 week after completion of treatment) effect of office-based vergence and anti-suppression therapy (OBVAT) on binocular vision and accommodative function when compared to observation alone in children with small-to-moderate angle intermittent exotropia (IXT).

Methods: In this single-masked (examiner masked), two-arm, single-centre randomised clinical trial, 40 participants, 6 to <18 years of age with untreated IXT were randomly assigned to OBVAT or observation alone. Participants assigned to therapy received 16 weeks of OBVAT (60 min per visit, once per week) with home reinforcement (15 min per day, 5 days a week). Therapy included vergence, accommodation and anti-suppression techniques. This paper reports the results of clinical measures of binocular vision and accommodation, including fusional vergence, near point of convergence, vergence facility, amplitude of accommodation, the Worth 4-dot test and the Fusion Maintenance Score (FMS).

Results: Treatment group differences at the primary outcome visit significantly favoured the OBVAT group (n = 20) over the observation group (n = 16) in negative fusional vergence break point at both distance (p ≤ 0.001; r = 0.58) and near (adjusted mean difference: 12.3 Δ; 95% CI: 5.3-19.3 Δ; p = 0.001; partial eta squared: 0.28), positive fusional vergence break point at both distance (p = 0.009; r = 0.43) and near (adjusted mean difference: 20.6 Δ; 95% CI: 11.8-29.4 Δ; p ≤ 0.001; partial eta squared: 0.41), vergence facility (adjusted mean difference: 5.6 cpm; 95% CI: 1.9-9.4 cpm; p = 0.005; partial eta squared: 0.22) and the FMS (p = 0.007; r = 0.44).

Conclusions: In this randomised clinical trial of participants aged 6 to <18 years with IXT, those in the OBVAT group had a significantly better fusional vergence range, vergence facility, near Worth 4-dot test result and FMS than the observation group at the 17-week visit. The improvement in these areas further support the effectiveness of OBVAT for improving IXT.

基于诊室的辐辏和抗抑制疗法对小中度角间歇性外斜患者双眼视力和调节的影响:随机临床试验。
目的:在小中度角间歇性外斜(IXT)患儿中,评估基于诊室的辐辏和抗抑制疗法(OBVAT)与单纯观察相比,对双眼视力和适应功能的短期(治疗完成后 1 周)影响:方法:在这一单掩蔽(检查者被掩蔽)、双臂、单中心随机临床试验中,有40名6至12岁的参与者参加:在远距离(p ≤ 0.001; r = 0.58)和近距离(调整后的平均差:12.3 Δ; 95% Δ)的负融合辐辏断点上,主要结果观察组(n = 20)明显优于观察组(n = 16):12.3 Δ; 95% CI: 5.3-19.3 Δ; p = 0.001; partial eta squared:0.28)、远距离(p = 0.009;r = 0.43)和近距离(调整后的平均差:20.6 Δ;95% CI:11.8-29.4 Δ;p ≤ 0.001;部分 eta 平方:0.41)、辐辏设施(调整后的平均差:5.6 cpm5.6 cpm; 95% CI: 1.9-9.4 cpm; p = 0.005; partial eta squared:结论:在这项随机临床试验中,参加者的年龄在 6 至 12 岁之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信