Olivia Kola, Michael Smigelski, Shavy Nagpal, Rozalba Gogaj, Samir S Taneja, James S Wysock, William C Huang
{"title":"Urine leak and vascular complications following robotic partial nephrectomy: a contemporary single-center experience.","authors":"Olivia Kola, Michael Smigelski, Shavy Nagpal, Rozalba Gogaj, Samir S Taneja, James S Wysock, William C Huang","doi":"10.1007/s11701-024-02096-1","DOIUrl":null,"url":null,"abstract":"<p><p>Urine leak (UL) and vascular complications (VC), i.e., pseudoaneurysms and arteriovenous fistulas are well-described complications of robotic-assisted partial nephrectomy (RAPN). Historically, UL incidence ranges from 0.3 to 17% and VC from 0.8 to 5.6%. We report the contemporary experience of UL and VC from a single, high-volume center in cases of RAPN. 447 patients were identified from an IRB-approved Renal Tumor Database of 2174 cases who underwent RAPN from 1/2017 to 5/2023. VC occurred in 9 cases (4 pseudoaneurysms, 1 AV fistula, 4 concurrent AV fistula/pseudoaneurysm), UL occurred in 9 (2.0%), and there was one concurrent case of VC and UL. Collecting-system entry occurred in five VC cases and five UL cases. For VCs, the median nephrometry score and maximal tumor diameter was 8 (IQR 3.0) and 3.8 (0.9) cm, respectively, and 8 (3.0) and 3.7 (1.1) cm for UL cases, respectively. Most complications occurred with tumors ≤ 4 mm from the collecting system (n = 7 VC, n = 6 UL). VCs presented after 18 (6.0) days, 6 with gross hematuria; 3 required clot irrigation, 1 required continuous bladder irrigation, and 8 required embolization. No patients required postoperative transfusion. Patients with UL presented after a median of 1 (12) day, with 5 cases detected by elevated creatinine in drain fluid and the remainder detected on routine ultrasound. The duration of UL was 13 (41) days with only 2 cases requiring stenting and one case requiring a drainage catheter. No patients required kidney re-operation or removal. Our rate of VC and UL following RAPN are low and consistent with other contemporary series. Complications occurred in patients with high nephrometry scores or tumors located close to the collecting system. Both complications generally present early and can be managed without kidney re-operation or removal.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"18 1","pages":"387"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-024-02096-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Urine leak (UL) and vascular complications (VC), i.e., pseudoaneurysms and arteriovenous fistulas are well-described complications of robotic-assisted partial nephrectomy (RAPN). Historically, UL incidence ranges from 0.3 to 17% and VC from 0.8 to 5.6%. We report the contemporary experience of UL and VC from a single, high-volume center in cases of RAPN. 447 patients were identified from an IRB-approved Renal Tumor Database of 2174 cases who underwent RAPN from 1/2017 to 5/2023. VC occurred in 9 cases (4 pseudoaneurysms, 1 AV fistula, 4 concurrent AV fistula/pseudoaneurysm), UL occurred in 9 (2.0%), and there was one concurrent case of VC and UL. Collecting-system entry occurred in five VC cases and five UL cases. For VCs, the median nephrometry score and maximal tumor diameter was 8 (IQR 3.0) and 3.8 (0.9) cm, respectively, and 8 (3.0) and 3.7 (1.1) cm for UL cases, respectively. Most complications occurred with tumors ≤ 4 mm from the collecting system (n = 7 VC, n = 6 UL). VCs presented after 18 (6.0) days, 6 with gross hematuria; 3 required clot irrigation, 1 required continuous bladder irrigation, and 8 required embolization. No patients required postoperative transfusion. Patients with UL presented after a median of 1 (12) day, with 5 cases detected by elevated creatinine in drain fluid and the remainder detected on routine ultrasound. The duration of UL was 13 (41) days with only 2 cases requiring stenting and one case requiring a drainage catheter. No patients required kidney re-operation or removal. Our rate of VC and UL following RAPN are low and consistent with other contemporary series. Complications occurred in patients with high nephrometry scores or tumors located close to the collecting system. Both complications generally present early and can be managed without kidney re-operation or removal.
期刊介绍:
The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.