A New Remote Monitoring System: Evaluation of the Efficiency and Accuracy of the Smart Emergency Medical System-Health Internet of Things Device.

IF 0.5 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Galen Medical Journal Pub Date : 2024-08-29 eCollection Date: 2024-01-01 DOI:10.31661/gmj.v13i.3376
Mohammad Taghi Hedayati Goudarzi, Hadi Zare Marzouni, Fazel Tarkhan, Ali Bijani, Mehdi Babagoli, Amirhossein Shadifar, Javad Abbas Alipour
{"title":"A New Remote Monitoring System: Evaluation of the Efficiency and Accuracy of the Smart Emergency Medical System-Health Internet of Things Device.","authors":"Mohammad Taghi Hedayati Goudarzi, Hadi Zare Marzouni, Fazel Tarkhan, Ali Bijani, Mehdi Babagoli, Amirhossein Shadifar, Javad Abbas Alipour","doi":"10.31661/gmj.v13i.3376","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The remote medical monitoring system can facilitate monitoring patients with cardiac arrhythmia, and consequently, reduce mortality and complications in individuals requiring emergency interventions. Hence, it is necessary to evaluate new telemedicine devices and compare them with standard devices. Therefore, this study aimed to evaluate and compare the new remote monitoring system, Smart Emergency Medical System-Health Internet of Things (SEMS-HIOT) developed by the Health Technology Development Centre of Babol University of Medical Sciences on patients with different cardiac arrhythmias and compare it with the standard device.</p><p><strong>Materials and methods: </strong>In this case-control study, 60 patients were divided into the six most common arrhythmia groups (n=10 per each group and equal gender) as atrial fibrillation, ventricular tachycardia, paroxysmal supraventricular tachycardia, premature ventricular contractions, atrial tachycardia, and premature atrial contractions. Also, 20 healthy individuals (including 10 men and 10 women) without any arrhythmia (normal rhythm) were considered as the control group. Three similar SEMS-HIOT devices were used as test devices and a standard cardiac monitoring device as the control device. The clinical parameters, including heart rate, pulse rate, oxygen saturation, body temperature, and cardiac electrical activity via electrocardiogram (ECG) lead-II were recorded.</p><p><strong>Results: </strong>Findings showed that the performance of the SEMS-HIOT test device was similar and in the same range for all indices in each group and there were no significant differences compared to the performance of the control device (P0.05). Also, the ECG records measured with SEMS-HIOT and standard device indicate no significant differences (P0.05).</p><p><strong>Conclusion: </strong>Our study showed that the cardiac indices as well as ECG findings, which were measured with SEMS-HIOT and common standard devices confirmed the accuracy and reliability of the new telematics device for monitoring patients with cardiac diseases.</p>","PeriodicalId":44017,"journal":{"name":"Galen Medical Journal","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11521570/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Galen Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/gmj.v13i.3376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The remote medical monitoring system can facilitate monitoring patients with cardiac arrhythmia, and consequently, reduce mortality and complications in individuals requiring emergency interventions. Hence, it is necessary to evaluate new telemedicine devices and compare them with standard devices. Therefore, this study aimed to evaluate and compare the new remote monitoring system, Smart Emergency Medical System-Health Internet of Things (SEMS-HIOT) developed by the Health Technology Development Centre of Babol University of Medical Sciences on patients with different cardiac arrhythmias and compare it with the standard device.

Materials and methods: In this case-control study, 60 patients were divided into the six most common arrhythmia groups (n=10 per each group and equal gender) as atrial fibrillation, ventricular tachycardia, paroxysmal supraventricular tachycardia, premature ventricular contractions, atrial tachycardia, and premature atrial contractions. Also, 20 healthy individuals (including 10 men and 10 women) without any arrhythmia (normal rhythm) were considered as the control group. Three similar SEMS-HIOT devices were used as test devices and a standard cardiac monitoring device as the control device. The clinical parameters, including heart rate, pulse rate, oxygen saturation, body temperature, and cardiac electrical activity via electrocardiogram (ECG) lead-II were recorded.

Results: Findings showed that the performance of the SEMS-HIOT test device was similar and in the same range for all indices in each group and there were no significant differences compared to the performance of the control device (P0.05). Also, the ECG records measured with SEMS-HIOT and standard device indicate no significant differences (P0.05).

Conclusion: Our study showed that the cardiac indices as well as ECG findings, which were measured with SEMS-HIOT and common standard devices confirmed the accuracy and reliability of the new telematics device for monitoring patients with cardiac diseases.

新型远程监控系统:评估智能紧急医疗系统--健康物联网设备的效率和准确性。
背景:远程医疗监控系统可帮助监控心律失常患者,从而降低需要紧急干预的患者的死亡率和并发症。因此,有必要对新型远程医疗设备进行评估,并与标准设备进行比较。因此,本研究旨在评估和比较巴博勒医科大学健康技术开发中心开发的新型远程监控系统--智能紧急医疗系统--健康物联网(SEMS-HIOT)对不同心律失常患者的作用,并将其与标准设备进行比较:在这项病例对照研究中,60 名患者被分为六组最常见的心律失常(每组 10 人,性别相同),即心房颤动、室性心动过速、阵发性室上性心动过速、室性早搏、房性心动过速和房性早搏。此外,20 名无任何心律失常(正常心律)的健康人(包括 10 名男性和 10 名女性)被视为对照组。三台类似的 SEMS-HIOT 设备作为测试设备,一台标准的心脏监测设备作为对照设备。记录临床参数,包括心率、脉搏、血氧饱和度、体温和心电图(ECG)II导联的心电活动:结果表明,SEMS-HIOT 测试设备的性能相似,每组的所有指标都在同一范围内,与对照设备的性能相比没有显著差异(P0.05)。此外,使用 SEMS-HIOT 和标准设备测量的心电图记录也没有明显差异(P0.05):我们的研究表明,使用 SEMS-HIOT 和普通标准设备测量的心脏指数和心电图结果证实了新型远程信息处理设备在监测心脏病患者方面的准确性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Galen Medical Journal
Galen Medical Journal MEDICINE, RESEARCH & EXPERIMENTAL-
自引率
0.00%
发文量
13
期刊介绍: GMJ is open access, peer-reviewed journal in English and supported by Noncommunicable Diseases (NCD) Research Center of Fasa University of Medical Sciences that publishing by Salvia Medical Sciences Ltd. GMJ will consider all types of the following scientific papers for publication: - Editorial’s choice - Original Researches - Review articles - Case reports - Case series - Letter (to editors, to authors, etc) - Short communications - Medical Idea
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信