Normal values and distribution of ventricular global longitudinal strain in 513 healthy fetuses measured by two-dimensional speckle-tracking echocardiography: a multi-institutional cohort study.

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Yohei Akazawa, Satoshi Yasukochi, Kohta Takei, Kiyohiro Takigiku, Noboru Inamura, Kimiyo Takagi, Ritsuko Kimata Pooh, Jun Yoshimatsu, Yoshimasa Kamei, Shunsuke Tamaru, Yuka Yamamoto, Takahito Miyake, Toshiyuki Hata
{"title":"Normal values and distribution of ventricular global longitudinal strain in 513 healthy fetuses measured by two-dimensional speckle-tracking echocardiography: a multi-institutional cohort study.","authors":"Yohei Akazawa, Satoshi Yasukochi, Kohta Takei, Kiyohiro Takigiku, Noboru Inamura, Kimiyo Takagi, Ritsuko Kimata Pooh, Jun Yoshimatsu, Yoshimasa Kamei, Shunsuke Tamaru, Yuka Yamamoto, Takahito Miyake, Toshiyuki Hata","doi":"10.1007/s00380-024-02477-4","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to determine the normal reference values and distribution of global longitudinal strain (GLS) in the right and left ventricles of healthy Japanese fetuses during pregnancy. This multi-institutional cohort study included healthy Japanese fetuses during normal pregnancies without maternal or fetal complications between 18 and 40 weeks of gestation. Two-dimensional fetal echocardiographic images of the four-chamber view with a high frame rate were acquired and stored as DICOM clips. Data were collected and analyzed in a central laboratory to measure the left ventricular (LV) and right ventricular (RV) GLS using two-dimensional speckle tracking. In total, 513 fetuses were enrolled. The mean LV-GLS and RV-GLS were - 24.3% ± 3.5% and - 23.5% ± 3.7%, respectively. The magnitude of the GLS, with normal limits in both ventricles, decreased with advancing gestation. LV values were r = 0.34 (95% confidence interval, 0.27-0.42) and p  < 0.0001; RV values were r = 0.33 (95% confidence interval, 0.25-0.41) and p  < 0.0001. The normal values of healthy Japanese fetuses in healthy pregnancies is the first to be established by the large-scale, multi-institutional cohort study as LV-GLS of 24.3% ± 3.5% and RV-GLS of - 23.5% ± 3.7%, respectively. This can serve as a basic reference for assessing the cardiac functions in Japanese fetuses with various heart diseases.</p>","PeriodicalId":12940,"journal":{"name":"Heart and Vessels","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart and Vessels","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00380-024-02477-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to determine the normal reference values and distribution of global longitudinal strain (GLS) in the right and left ventricles of healthy Japanese fetuses during pregnancy. This multi-institutional cohort study included healthy Japanese fetuses during normal pregnancies without maternal or fetal complications between 18 and 40 weeks of gestation. Two-dimensional fetal echocardiographic images of the four-chamber view with a high frame rate were acquired and stored as DICOM clips. Data were collected and analyzed in a central laboratory to measure the left ventricular (LV) and right ventricular (RV) GLS using two-dimensional speckle tracking. In total, 513 fetuses were enrolled. The mean LV-GLS and RV-GLS were - 24.3% ± 3.5% and - 23.5% ± 3.7%, respectively. The magnitude of the GLS, with normal limits in both ventricles, decreased with advancing gestation. LV values were r = 0.34 (95% confidence interval, 0.27-0.42) and p  < 0.0001; RV values were r = 0.33 (95% confidence interval, 0.25-0.41) and p  < 0.0001. The normal values of healthy Japanese fetuses in healthy pregnancies is the first to be established by the large-scale, multi-institutional cohort study as LV-GLS of 24.3% ± 3.5% and RV-GLS of - 23.5% ± 3.7%, respectively. This can serve as a basic reference for assessing the cardiac functions in Japanese fetuses with various heart diseases.

通过二维斑点追踪超声心动图测量 513 名健康胎儿心室整体纵向应变的正常值和分布:一项多机构队列研究。
这项研究旨在确定日本健康胎儿妊娠期左右心室整体纵向应变(GLS)的正常参考值和分布。这项多机构队列研究纳入了妊娠18至40周、正常妊娠且无母体或胎儿并发症的健康日本胎儿。研究人员采集了高帧率四腔切面的二维胎儿超声心动图,并将其存储为 DICOM 片段。数据由中心实验室收集和分析,利用二维斑点追踪技术测量左心室(LV)和右心室(RV)的GLS。共有 513 个胎儿参与了这项研究。LV-GLS 和 RV-GLS 的平均值分别为 - 24.3% ± 3.5% 和 - 23.5% ± 3.7%。两个心室的GLS幅度均为正常范围,但随着妊娠期的延长而减小。LV 值为 r = 0.34(95% 置信区间,0.27-0.42),p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Heart and Vessels
Heart and Vessels 医学-外周血管病
CiteScore
3.10
自引率
13.30%
发文量
211
审稿时长
2 months
期刊介绍: Heart and Vessels is an English-language journal that provides a forum of original ideas, excellent methods, and fascinating techniques on cardiovascular disease fields. All papers submitted for publication are evaluated only with regard to scientific quality and relevance to the heart and vessels. Contributions from those engaged in practical medicine, as well as from those involved in basic research, are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信