Sangbaek Lee , Tomas Polakovic , Whitney Armstrong , Alan Dibos , Timothy Draher , Nathaniel Pastika , Zein-Eddine Meziani , Valentine Novosad
{"title":"Beam tests of SNSPDs with 120 GeV protons","authors":"Sangbaek Lee , Tomas Polakovic , Whitney Armstrong , Alan Dibos , Timothy Draher , Nathaniel Pastika , Zein-Eddine Meziani , Valentine Novosad","doi":"10.1016/j.nima.2024.169956","DOIUrl":null,"url":null,"abstract":"<div><div>We report the test results for a 120<!--> <!-->GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 2.82<!--> <!-->K. The relative detection efficiency was extracted from bias current scans for each device. The results show that the wire width is a critical factor in determining the detection efficiency and larger wire widths than 400<!--> <!-->nm leads to inefficiencies at low bias currents. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1069 ","pages":"Article 169956"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900224008829","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 2.82 K. The relative detection efficiency was extracted from bias current scans for each device. The results show that the wire width is a critical factor in determining the detection efficiency and larger wire widths than 400 nm leads to inefficiencies at low bias currents. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.
期刊介绍:
Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section.
Theoretical as well as experimental papers are accepted.