Martina Bonvicini, Carlo Monaco, Antonio Arena, Ugo Consolo, Davide Silvestri, Francesca Zicari
{"title":"Color Stability of PMMA Resins for Complete Dentures Produced with CAD/CAM and 3D-Printing Technologies: An In Vitro Study.","authors":"Martina Bonvicini, Carlo Monaco, Antonio Arena, Ugo Consolo, Davide Silvestri, Francesca Zicari","doi":"10.11607/ijp.9191","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effect of a staining solution on the color stability of resins for complete dentures produced with conventional and digital technologies.</p><p><strong>Materials and methods: </strong>A total of 60 resin specimens were prepared and divided into six groups of 10 specimens each: Probase Hot (PH; Ivoclar), IvoBase CAD (IBC; Ivoclar), Ivotion Dent (ID; Ivoclar), Ivotion Dent Multi (IDM; Ivoclar), Dima Print Denture Base (DPDB; Kulzer), and Dima Print Denture Teeth (DPDT; Kulzer). One surface of each specimen was polished following the manufacturer's instructions. The CIELab color differences were evaluated before and after 28 days of immersion in a coffee solution and measured as ∆E using two dental spectrophotometers. One specimen for each group was selected for scanning electron microscopy (SEM) analysis at baseline and at 28 days.</p><p><strong>Results: </strong>Data analysis was performed with Kruskal-Wallis test and post-hoc Dunn test for comparison. Regarding specimens analyzed with VITA Easyshade, IDM white zone (polished and unpolished) scored higher (∆E = 0.87 and ∆E = 1.15, respectively). All milled samples (IBC, ID, IDM pink zone), scored significantly higher compared to PH and DPDT. Regarding SpectroShade, IDM pink zone performed better for both polished and unpolished specimens (∆E = 1.57 and ∆E = 2.07, respectively). ID demonstrated a statistically higher color stability compared to PH and DPDT. Regarding SEM analysis, any difference in surface morphology was observed between baseline and 28-day immersion analyses.</p><p><strong>Conclusions: </strong>Color stability was significantly higher in resin specimens obtained with digital technologies compared to conventional resin specimens afterimmersion in a staining solution.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"365-373"},"PeriodicalIF":1.8000,"publicationDate":"2025-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the effect of a staining solution on the color stability of resins for complete dentures produced with conventional and digital technologies.
Materials and methods: A total of 60 resin specimens were prepared and divided into six groups of 10 specimens each: Probase Hot (PH; Ivoclar), IvoBase CAD (IBC; Ivoclar), Ivotion Dent (ID; Ivoclar), Ivotion Dent Multi (IDM; Ivoclar), Dima Print Denture Base (DPDB; Kulzer), and Dima Print Denture Teeth (DPDT; Kulzer). One surface of each specimen was polished following the manufacturer's instructions. The CIELab color differences were evaluated before and after 28 days of immersion in a coffee solution and measured as ∆E using two dental spectrophotometers. One specimen for each group was selected for scanning electron microscopy (SEM) analysis at baseline and at 28 days.
Results: Data analysis was performed with Kruskal-Wallis test and post-hoc Dunn test for comparison. Regarding specimens analyzed with VITA Easyshade, IDM white zone (polished and unpolished) scored higher (∆E = 0.87 and ∆E = 1.15, respectively). All milled samples (IBC, ID, IDM pink zone), scored significantly higher compared to PH and DPDT. Regarding SpectroShade, IDM pink zone performed better for both polished and unpolished specimens (∆E = 1.57 and ∆E = 2.07, respectively). ID demonstrated a statistically higher color stability compared to PH and DPDT. Regarding SEM analysis, any difference in surface morphology was observed between baseline and 28-day immersion analyses.
Conclusions: Color stability was significantly higher in resin specimens obtained with digital technologies compared to conventional resin specimens afterimmersion in a staining solution.