{"title":"The Accuracy of Custom-Made Milled Metal Posts as Compared to Conventional Cast Metal Posts.","authors":"Tabarak M Al-Rubaye, Emad S Elsubeihi","doi":"10.3390/dj12100309","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study was to compare the fitting accuracy of custom-made metal posts and cores fabricated by half-digital and milling technique to that of conventional cast posts fabricated by direct technique.</p><p><strong>Methods: </strong>Sixteen extracted single-rooted teeth were endodontically treated followed by post space preparation. A direct resin post and core pattern was made for each tooth and used for the fabrication of two posts (n = 16). Each post resin pattern was digitized with a laboratory scanner and used for the fabrication of a milled cobalt-chrome (Co-Cr) alloy post, while the direct resin pattern, after scanning, was cast in a Co-Cr alloy to produce a cast post. Each post was seated on its respective tooth and evaluated using microcomputed tomography. The following variables were evaluated: total space volume between the post and root canal, the volume and distance of the apical gap between each post and the remaining apical root canal filling, as well as the distance and surface area of the space between the post and lateral root canal wall at four determined points along the length of each post.</p><p><strong>Results: </strong>The results revealed that half-digital and milled posts had a statistically significantly higher total space volume (<i>p</i> < 0.05), apical gap volume (<i>p</i> < 0.02) and distance (<i>p</i> < 0.02), as well as a higher surface area of space between the post and root canal wall at the cervical area as compared to the cast post (<i>p</i> < 0.05).</p><p><strong>Conclusions: </strong>This study demonstrated that the fitting accuracy of cast posts was more accurate than posts fabricated with half-digital and milling technique.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"12 10","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11506045/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj12100309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of this study was to compare the fitting accuracy of custom-made metal posts and cores fabricated by half-digital and milling technique to that of conventional cast posts fabricated by direct technique.

Methods: Sixteen extracted single-rooted teeth were endodontically treated followed by post space preparation. A direct resin post and core pattern was made for each tooth and used for the fabrication of two posts (n = 16). Each post resin pattern was digitized with a laboratory scanner and used for the fabrication of a milled cobalt-chrome (Co-Cr) alloy post, while the direct resin pattern, after scanning, was cast in a Co-Cr alloy to produce a cast post. Each post was seated on its respective tooth and evaluated using microcomputed tomography. The following variables were evaluated: total space volume between the post and root canal, the volume and distance of the apical gap between each post and the remaining apical root canal filling, as well as the distance and surface area of the space between the post and lateral root canal wall at four determined points along the length of each post.

Results: The results revealed that half-digital and milled posts had a statistically significantly higher total space volume (p < 0.05), apical gap volume (p < 0.02) and distance (p < 0.02), as well as a higher surface area of space between the post and root canal wall at the cervical area as compared to the cast post (p < 0.05).

Conclusions: This study demonstrated that the fitting accuracy of cast posts was more accurate than posts fabricated with half-digital and milling technique.

定制铣制金属支柱与传统铸造金属支柱的精度比较
目的:本研究的目的是比较采用半数字和铣削技术制作的定制金属桩和桩核与采用直接技术制作的传统铸造桩的配合精度:方法:对 16 颗拔出的单根牙进行根管治疗,然后进行桩间隙预备。为每颗牙齿制作了直接树脂桩和桩核模型,并用于制作两个桩(n = 16)。用实验室扫描仪对每个牙柱树脂模型进行数字化处理,然后用于制作钴铬(Co-Cr)合金牙柱,而扫描后的直接树脂模型则用钴铬合金浇铸成铸造牙柱。每个基桩都安装在各自的牙齿上,并使用微计算机断层扫描进行评估。对以下变量进行了评估:牙柱与根管之间的总空间体积、每个牙柱与剩余根尖充填物之间的根尖间隙的体积和距离,以及沿每个牙柱长度方向四个确定点的牙柱与侧根管壁之间的空间距离和表面积:结果显示,与铸造桩相比,半数字桩和磨制桩的总空间体积(p < 0.05)、根尖间隙体积(p < 0.02)和距离(p < 0.02)以及桩体与根管壁在颈部的空间表面积(p < 0.05)均显著高于铸造桩(p < 0.05):本研究表明,铸造桩的安装精度高于半数字和铣削技术制作的桩。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信