{"title":"Microfocus X-Ray Computed Tomography of <i>Paraplanocera oligoglena</i> (Platyhelminthes: Polycladida) with an Evaluation of Histological Sections After Scanning.","authors":"Yuki Oya, Akiteru Maeno, Aoi Tsuyuki, Hisanori Kohtsuka, Hiroshi Kajihara","doi":"10.2108/zs240015","DOIUrl":null,"url":null,"abstract":"<p><p>Microfocus X-ray computed tomography (micro-CT) is expected to be utilized in the taxonomy of macroturbellarians that require histological technique(s) for identification, allowing nondestructive observation of the internal structures of specimens in a short time. With micro-CT, we observed a polyclad flatworm, <i>Paraplanocera oligoglena</i> (Schmarda, 1859), in this study. In the CT images, the main reproductive organs in the polyclad specimen were well observed, but some diagnostic characters were unclear or undetectable. We also prepared histological sections from the CT-scanned specimen. The histological sections were still observable and we could confirm the structures that were indistinct in the CT images; however, dye-affinity of tissues was slightly altered compared with those in usual sections. Integrating information from micro-CT images and subsequent histological observations, we successfully generated a 3D model of the reproductive organs of the polyclad. Our results suggest that the micro-CT imaging, as of the current resolution, would not completely replace the traditional histological technique; instead, these two techniques need to complement each other for a better understanding of the morphology that underpins the polyclad systematics.</p>","PeriodicalId":24040,"journal":{"name":"Zoological Science","volume":"41 5","pages":"471-478"},"PeriodicalIF":0.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zoological Science","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.2108/zs240015","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ZOOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Microfocus X-ray computed tomography (micro-CT) is expected to be utilized in the taxonomy of macroturbellarians that require histological technique(s) for identification, allowing nondestructive observation of the internal structures of specimens in a short time. With micro-CT, we observed a polyclad flatworm, Paraplanocera oligoglena (Schmarda, 1859), in this study. In the CT images, the main reproductive organs in the polyclad specimen were well observed, but some diagnostic characters were unclear or undetectable. We also prepared histological sections from the CT-scanned specimen. The histological sections were still observable and we could confirm the structures that were indistinct in the CT images; however, dye-affinity of tissues was slightly altered compared with those in usual sections. Integrating information from micro-CT images and subsequent histological observations, we successfully generated a 3D model of the reproductive organs of the polyclad. Our results suggest that the micro-CT imaging, as of the current resolution, would not completely replace the traditional histological technique; instead, these two techniques need to complement each other for a better understanding of the morphology that underpins the polyclad systematics.

副栉水母(Platyhelminthes: Polycladida)的微焦点 X 射线计算机断层扫描以及扫描后组织切片的评估。
微焦 X 射线计算机断层扫描(micro-CT)可在短时间内对标本的内部结构进行无损观察,有望用于需要组织学技术鉴定的大型扁形动物的分类学研究。在这项研究中,我们利用显微 CT 技术观察了一种多壳扁形虫--Paraplanocera oligoglena(Schmarda,1859 年)。在 CT 图像中,我们很好地观察到了多足扁形虫标本的主要生殖器官,但有些诊断特征不清楚或无法检测。我们还制作了 CT 扫描标本的组织切片。组织切片仍然可以观察到,而且我们可以确认 CT 图像中不清晰的结构;不过,与普通切片相比,组织的染料亲和性略有改变。综合显微 CT 图像信息和随后的组织学观察结果,我们成功生成了多角体生殖器官的三维模型。我们的研究结果表明,就目前的分辨率而言,显微 CT 成像技术并不能完全取代传统的组织学技术;相反,这两种技术需要相互补充,以更好地理解作为多鳃类系统学基础的形态学。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Zoological Science
Zoological Science 生物-动物学
CiteScore
1.70
自引率
11.10%
发文量
59
审稿时长
1 months
期刊介绍: Zoological Science is published by the Zoological Society of Japan and devoted to publication of original articles, reviews and editorials that cover the broad field of zoology. The journal was founded in 1984 as a result of the consolidation of Zoological Magazine (1888–1983) and Annotationes Zoologicae Japonenses (1897–1983), the former official journals of the Zoological Society of Japan. Each annual volume consists of six regular issues, one every two months.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信