Dilution dysfunction: evaluation of automated disinfectant dispenser systems in 10 hospitals demonstrates a need for improved monitoring to ensure that correct disinfectant concentrations are delivered.
Jennifer L Cadnum, Claire E Kaple, Elizabeth C Eckstein, Elie A Saade, Amy J Ray, Trina F Zabarsky, Bernardino J Guerrero, Mohamed H Yassin, Curtis J Donskey
{"title":"Dilution dysfunction: evaluation of automated disinfectant dispenser systems in 10 hospitals demonstrates a need for improved monitoring to ensure that correct disinfectant concentrations are delivered.","authors":"Jennifer L Cadnum, Claire E Kaple, Elizabeth C Eckstein, Elie A Saade, Amy J Ray, Trina F Zabarsky, Bernardino J Guerrero, Mohamed H Yassin, Curtis J Donskey","doi":"10.1017/ice.2024.148","DOIUrl":null,"url":null,"abstract":"<p><p>Automated dispensers that dilute concentrated disinfectants with water are commonly used in healthcare facilities. In a point-prevalence product evaluation, 9 of 10 (90%) hospitals using dilutable disinfectants had 1 or more malfunctioning dispensers. Twenty-nine of 107 (27.1%) systems dispensed product with lower-than-expected concentrations, including 15 (14.0%) with no detectable disinfectant.</p>","PeriodicalId":13663,"journal":{"name":"Infection Control and Hospital Epidemiology","volume":" ","pages":"1-4"},"PeriodicalIF":3.0000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infection Control and Hospital Epidemiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1017/ice.2024.148","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0
Abstract
Automated dispensers that dilute concentrated disinfectants with water are commonly used in healthcare facilities. In a point-prevalence product evaluation, 9 of 10 (90%) hospitals using dilutable disinfectants had 1 or more malfunctioning dispensers. Twenty-nine of 107 (27.1%) systems dispensed product with lower-than-expected concentrations, including 15 (14.0%) with no detectable disinfectant.
期刊介绍:
Infection Control and Hospital Epidemiology provides original, peer-reviewed scientific articles for anyone involved with an infection control or epidemiology program in a hospital or healthcare facility. Written by infection control practitioners and epidemiologists and guided by an editorial board composed of the nation''s leaders in the field, ICHE provides a critical forum for this vital information.