Preparation of a V-COF@SWCNTs-COOH/SPCE supported molecularly imprinted electrochemical sensor for real-time detection of trace sulfadimidine.

IF 5.6 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Talanta Pub Date : 2025-01-01 Epub Date: 2024-10-15 DOI:10.1016/j.talanta.2024.127046
Shuomeng Bai, Tingting Yang, Peiqiao Liu, Junhua Tan, Shuixie Chen, Hongtao Lei, Xiaoqun Wei
{"title":"Preparation of a V-COF@SWCNTs-COOH/SPCE supported molecularly imprinted electrochemical sensor for real-time detection of trace sulfadimidine.","authors":"Shuomeng Bai, Tingting Yang, Peiqiao Liu, Junhua Tan, Shuixie Chen, Hongtao Lei, Xiaoqun Wei","doi":"10.1016/j.talanta.2024.127046","DOIUrl":null,"url":null,"abstract":"<p><p>To overcome the limitations of insufficient sensitivity and poor specificity of portable screen-printed carbon electrode-electrochemical sensors (SPCE-EC) in practical applications, we prepared carrier composites of carboxylic single-walled carbon nanotubes vertically grafted by covalent organic frameworks (v-COF@SWCNTs-COOH) and coated with a molecularly imprinted polymer (MIP) of sulfadimidine (SM<sub>2</sub>). 55 °C hot steam elution is more eco-friendly than traditional organic solvent elution. The results showed that when the mass ratio of DBA to DBA-SWCNTs was 1:1, the v-COF@SWCNTs-COOH obtained by the two-step synthesis method could increase the electrical signal up to 2.33-fold of the bare electrode. The bifunctional monomer MIP prepared on the above structure enhanced the signal response by 2.91-fold, with a high imprint factor of 20. The assembled MIP/v-COF@SWCNTs-COOH/SPCE were analyzed by differential pulse voltammetry (DPV) with a high sensitivity of 0.21 nM for LOD and 0.70 nM for LOQ. In milk and fish samples, the recovery rate was 95.0 %-104.8 %. The validation of authentic pork samples with the statutory LC-MS/MS method showed no significant difference (P > 0.05). The sensor's performance indicators remained robust after five repeated uses. Therefore, the MIP/v-COF@SWCNTs-COOH/SPCE combines the cheapness and portability of SPCE, while the sensitivity and specificity of small molecule detection were significantly improved.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"282 ","pages":"127046"},"PeriodicalIF":5.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.127046","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

To overcome the limitations of insufficient sensitivity and poor specificity of portable screen-printed carbon electrode-electrochemical sensors (SPCE-EC) in practical applications, we prepared carrier composites of carboxylic single-walled carbon nanotubes vertically grafted by covalent organic frameworks (v-COF@SWCNTs-COOH) and coated with a molecularly imprinted polymer (MIP) of sulfadimidine (SM2). 55 °C hot steam elution is more eco-friendly than traditional organic solvent elution. The results showed that when the mass ratio of DBA to DBA-SWCNTs was 1:1, the v-COF@SWCNTs-COOH obtained by the two-step synthesis method could increase the electrical signal up to 2.33-fold of the bare electrode. The bifunctional monomer MIP prepared on the above structure enhanced the signal response by 2.91-fold, with a high imprint factor of 20. The assembled MIP/v-COF@SWCNTs-COOH/SPCE were analyzed by differential pulse voltammetry (DPV) with a high sensitivity of 0.21 nM for LOD and 0.70 nM for LOQ. In milk and fish samples, the recovery rate was 95.0 %-104.8 %. The validation of authentic pork samples with the statutory LC-MS/MS method showed no significant difference (P > 0.05). The sensor's performance indicators remained robust after five repeated uses. Therefore, the MIP/v-COF@SWCNTs-COOH/SPCE combines the cheapness and portability of SPCE, while the sensitivity and specificity of small molecule detection were significantly improved.

制备用于实时检测痕量磺胺二甲嘧啶的 V-COF@SWCNTs-COOH/SPCE 分子印迹电化学传感器。
为了克服便携式丝网印刷碳电极电化学传感器(SPCE-EC)在实际应用中灵敏度不足和特异性差的局限性,我们制备了共价有机框架垂直接枝的羧基单壁碳纳米管(v-COF@SWCNTs-COOH)载体复合材料,并在其表面涂覆了磺胺二甲嘧啶(SM2)分子印迹聚合物(MIP)。55 °C 热蒸汽洗脱比传统的有机溶剂洗脱更环保。结果表明,当 DBA 与 DBA-SWCNTs 的质量比为 1:1 时,两步合成法得到的 v-COF@SWCNTs-COOH 可使电信号增加到裸电极的 2.33 倍。在上述结构上制备的双功能单体 MIP 将信号响应提高了 2.91 倍,印记因子高达 20。通过差分脉冲伏安法(DPV)对组装好的 MIP/v-COF@SWCNTs-COOH/SPCE 进行分析,灵敏度很高,LOD 为 0.21 nM,LOQ 为 0.70 nM。在牛奶和鱼肉样品中,回收率为 95.0 %-104.8 %。用法定的 LC-MS/MS 方法对真实的猪肉样品进行验证,结果显示两者无显著差异(P > 0.05)。该传感器的性能指标在重复使用五次后仍然保持稳定。因此,MIP/v-COF@SWCNTs-COOH/SPCE 集 SPCE 的廉价性和便携性于一身,同时显著提高了小分子检测的灵敏度和特异性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信