{"title":"An SSDLs calibration method for the kerma-area product meter","authors":"Qian Yang, Shimeng Xu, Jie Fan","doi":"10.1016/j.radphyschem.2024.112299","DOIUrl":null,"url":null,"abstract":"<div><div>The kerma-area product meter (KAP meter) is mainly used for quality assurance in medical imaging research, providing dose quality assessment or dose monitoring for patients. It can be calibrated either in the laboratory or on-site. The purpose of this study is to propose a method for calibrating the KAP meter using a plane-parallel transmission ionization chamber in the SSDLs. In the range of 50 kV–150 kV, under RQR (standard radiation qualities) and RQR additional filtering conditions of the KAP meter, the correction factor <span><math><mrow><msubsup><mi>N</mi><mi>Q</mi><mi>m</mi></msubsup></mrow></math></span> of the transmission ionization chamber is calculated to select two types of KAP meters for the calibration of the transmitted beam. The collimators used to limit the size of the radiation field are respectively 50.07 mm in length, 30.03 mm in length, and 20.05 mm in radius. This method, with uncertainty not exceeding 3.0% while improving calibration efficiency, can replace the unit-specific correction of the laboratory method (Toroi et al., 2008).</div></div>","PeriodicalId":20861,"journal":{"name":"Radiation Physics and Chemistry","volume":"226 ","pages":"Article 112299"},"PeriodicalIF":2.8000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Physics and Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969806X24007916","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The kerma-area product meter (KAP meter) is mainly used for quality assurance in medical imaging research, providing dose quality assessment or dose monitoring for patients. It can be calibrated either in the laboratory or on-site. The purpose of this study is to propose a method for calibrating the KAP meter using a plane-parallel transmission ionization chamber in the SSDLs. In the range of 50 kV–150 kV, under RQR (standard radiation qualities) and RQR additional filtering conditions of the KAP meter, the correction factor of the transmission ionization chamber is calculated to select two types of KAP meters for the calibration of the transmitted beam. The collimators used to limit the size of the radiation field are respectively 50.07 mm in length, 30.03 mm in length, and 20.05 mm in radius. This method, with uncertainty not exceeding 3.0% while improving calibration efficiency, can replace the unit-specific correction of the laboratory method (Toroi et al., 2008).
期刊介绍:
Radiation Physics and Chemistry is a multidisciplinary journal that provides a medium for publication of substantial and original papers, reviews, and short communications which focus on research and developments involving ionizing radiation in radiation physics, radiation chemistry and radiation processing.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. This could include papers that are very similar to previous publications, only with changed target substrates, employed materials, analyzed sites and experimental methods, report results without presenting new insights and/or hypothesis testing, or do not focus on the radiation effects.