Relationship between asymmetry of transverse sinus and difference in intraocular pressure Based on MRV imaging examination

IF 2.5 4区 医学 Q3 BIOCHEMICAL RESEARCH METHODS
Dan Zhu , Weiguang Zhang , Dongtai Zhang , Dong Qiu , Zhenyang Yu , Yiwen Jiang
{"title":"Relationship between asymmetry of transverse sinus and difference in intraocular pressure Based on MRV imaging examination","authors":"Dan Zhu ,&nbsp;Weiguang Zhang ,&nbsp;Dongtai Zhang ,&nbsp;Dong Qiu ,&nbsp;Zhenyang Yu ,&nbsp;Yiwen Jiang","doi":"10.1016/j.slast.2024.100202","DOIUrl":null,"url":null,"abstract":"<div><div>Transverse sinus asymmetry refers to the inconsistencies in the shape structure, size or blood flow of the intracranial transverse sinus. Intraocular pressure difference refers to the obvious difference in intraocular pressure between the two eyes. Transversal sinus asymmetry may be correlated with intraocular pressure difference, but the mechanism of correlation is still unclear. To investigate the relationship between transverse sinus asymmetry and IOP differences based on MRV examination, and to explore the possible mechanism. Patients with transverse sinus asymmetry were selected and examined using the MRV technique. At the same time, the patients' IOP was measured using standard methods of IOP measurement. Correlation analysis and statistical methods were used to evaluate the association between transverse sinus asymmetry and IOP differences. There was a statistically significant distinction observed between groups I and V (<em>Z</em> = 6.78, <em>P</em> &lt; 0.01). Significant variations were also noted in the intraocular pressures across all groups, encompassing the average measurements of the right eye and left eye, along with the variance between the two (right eye: <em>F</em> = 15.43, <em>P</em> &lt; 0.01; left eye: <em>F</em> = 4.62, <em>P</em> = 0.002; variance between eyes: <em>F</em> = 41.79, <em>P</em> &lt; 0.01). The asymmetry of the transverse sinus exhibited a negative relationship with the intraocular pressure of the right eye (<em>r</em> = 0.51, <em>P</em> &lt; 0.01) and the difference between the pressures of the two eyes (<em>r</em> = 0.79, <em>P</em> &lt; 0.01); no significant association was found between the asymmetry and the left eye's intraocular pressure. In conclusion, a certain correlation exists between the intraocular pressures of the left and right eyes and the morphology of the transverse sinus. When the transverse sinus is thicker on one side, the corresponding drainage veins are thicker, resulting in lower intraocular pressure on that same side.</div></div>","PeriodicalId":54248,"journal":{"name":"SLAS Technology","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SLAS Technology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2472630324000840","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Transverse sinus asymmetry refers to the inconsistencies in the shape structure, size or blood flow of the intracranial transverse sinus. Intraocular pressure difference refers to the obvious difference in intraocular pressure between the two eyes. Transversal sinus asymmetry may be correlated with intraocular pressure difference, but the mechanism of correlation is still unclear. To investigate the relationship between transverse sinus asymmetry and IOP differences based on MRV examination, and to explore the possible mechanism. Patients with transverse sinus asymmetry were selected and examined using the MRV technique. At the same time, the patients' IOP was measured using standard methods of IOP measurement. Correlation analysis and statistical methods were used to evaluate the association between transverse sinus asymmetry and IOP differences. There was a statistically significant distinction observed between groups I and V (Z = 6.78, P < 0.01). Significant variations were also noted in the intraocular pressures across all groups, encompassing the average measurements of the right eye and left eye, along with the variance between the two (right eye: F = 15.43, P < 0.01; left eye: F = 4.62, P = 0.002; variance between eyes: F = 41.79, P < 0.01). The asymmetry of the transverse sinus exhibited a negative relationship with the intraocular pressure of the right eye (r = 0.51, P < 0.01) and the difference between the pressures of the two eyes (r = 0.79, P < 0.01); no significant association was found between the asymmetry and the left eye's intraocular pressure. In conclusion, a certain correlation exists between the intraocular pressures of the left and right eyes and the morphology of the transverse sinus. When the transverse sinus is thicker on one side, the corresponding drainage veins are thicker, resulting in lower intraocular pressure on that same side.
横窦不对称与眼压差异之间的关系 基于 MRV 成像检查
横窦不对称是指颅内横窦的形状结构、大小或血流不一致。眼压差是指两眼眼压的明显差异。横窦不对称可能与眼压差相关,但相关机制尚不清楚。研究基于 MRV 检查的横窦不对称与眼压差异之间的关系,并探讨其可能的机制。选取横窦不对称患者,使用 MRV 技术对其进行检查。同时,使用标准的眼压测量方法测量患者的眼压。采用相关分析和统计方法评估横向窦不对称与眼压差异之间的关联。第一组和第五组之间的差异具有统计学意义(Z = 6.78,P < 0.01)。各组的眼压也存在显著差异,包括右眼和左眼的平均测量值,以及两者之间的差异(右眼:右眼:F = 15.43,P = 0.01;左眼:F = 4.62,P = 0.01:F = 4.62,P = 0.002;两眼之间的差异:F = 41.79,P < 0.01)。横窦的不对称性与右眼眼压(r = 0.51,P <0.01)和两眼眼压差(r = 0.79,P <0.01)呈负相关;不对称与左眼眼压无明显关系。总之,左右眼的眼压与横窦的形态存在一定的相关性。当一侧横窦较厚时,相应的排水静脉也较厚,从而导致同侧眼压较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SLAS Technology
SLAS Technology Computer Science-Computer Science Applications
CiteScore
6.30
自引率
7.40%
发文量
47
审稿时长
106 days
期刊介绍: SLAS Technology emphasizes scientific and technical advances that enable and improve life sciences research and development; drug-delivery; diagnostics; biomedical and molecular imaging; and personalized and precision medicine. This includes high-throughput and other laboratory automation technologies; micro/nanotechnologies; analytical, separation and quantitative techniques; synthetic chemistry and biology; informatics (data analysis, statistics, bio, genomic and chemoinformatics); and more.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信