Atmospheric CO2 monitoring to identify zones of increased airborne pathogen transmission risk in hospital settings.

IF 3.8 3区 医学 Q2 INFECTIOUS DISEASES
Andrew P Shoubridge, Amanda Brass, Levi Elms, Sarah K Sims, Angela Anderson, Dylan Mordaunt, Maria Crotty, Lito E Papanicolas, Steven L Taylor, Geraint B Rogers
{"title":"Atmospheric CO<sub>2</sub> monitoring to identify zones of increased airborne pathogen transmission risk in hospital settings.","authors":"Andrew P Shoubridge, Amanda Brass, Levi Elms, Sarah K Sims, Angela Anderson, Dylan Mordaunt, Maria Crotty, Lito E Papanicolas, Steven L Taylor, Geraint B Rogers","doi":"10.1016/j.ajic.2024.10.001","DOIUrl":null,"url":null,"abstract":"<p><p>Measures to reduce airborne pathogen transmission in health care settings, such as increased air exchange, air decontamination, and reductions in peak occupancy, can be expensive and disruptive, particularly when employed in an untargeted manner. We report the empirical identification of high transmission risk zones in a tertiary hospital, using carbon dioxide-based assessments of air exchange. This rapid, cost-effective, and unobtrusive approach led to the targeted remediation of a high transmission risk zone.</p>","PeriodicalId":7621,"journal":{"name":"American journal of infection control","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of infection control","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ajic.2024.10.001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Measures to reduce airborne pathogen transmission in health care settings, such as increased air exchange, air decontamination, and reductions in peak occupancy, can be expensive and disruptive, particularly when employed in an untargeted manner. We report the empirical identification of high transmission risk zones in a tertiary hospital, using carbon dioxide-based assessments of air exchange. This rapid, cost-effective, and unobtrusive approach led to the targeted remediation of a high transmission risk zone.

通过大气二氧化碳监测来确定医院环境中空气传播病原体风险增加的区域。
在医疗机构中减少空气传播病原体的措施,如增加空气交换、空气净化和减少高峰占用率等,可能既昂贵又具有破坏性,尤其是在没有针对性的情况下。我们报告了利用基于二氧化碳的空气交换评估对一家三级医院的高传播风险区进行的实证识别。这种快速、经济、无干扰的方法可对高传播风险区进行有针对性的补救。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.40
自引率
4.10%
发文量
479
审稿时长
24 days
期刊介绍: AJIC covers key topics and issues in infection control and epidemiology. Infection control professionals, including physicians, nurses, and epidemiologists, rely on AJIC for peer-reviewed articles covering clinical topics as well as original research. As the official publication of the Association for Professionals in Infection Control and Epidemiology (APIC)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信