Lukas Goertz, Sophia Hohenstatt, Dominik F Vollherbst, Charlotte S Weyland, Omid Nikoubashman, Christian Gronemann, Muriel Pflaeging, Eberhard Siebert, Georg Bohner, David Zopfs, Marc Schlamann, Thomas Liebig, Franziska Dorn, Martin Wiesmann, Markus A Möhlenbruch, Christoph Kabbasch
{"title":"Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy: A multicenter study.","authors":"Lukas Goertz, Sophia Hohenstatt, Dominik F Vollherbst, Charlotte S Weyland, Omid Nikoubashman, Christian Gronemann, Muriel Pflaeging, Eberhard Siebert, Georg Bohner, David Zopfs, Marc Schlamann, Thomas Liebig, Franziska Dorn, Martin Wiesmann, Markus A Möhlenbruch, Christoph Kabbasch","doi":"10.1177/15910199241286542","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This multicenter study evaluates the safety and efficacy of coated flow diverters (cFDs) for the treatment of cerebral aneurysms under single antiplatelet therapy (SAPT).</p><p><strong>Methods: </strong>This is a retrospective, observational study of 41 patients (median age: 58 years) with 41 aneurysms (median size: 7 mm, 29 [71%] saccular, 9 [22%] ruptured) treated with cFDs at four neurovascular centers between 2020 and 2023. Scheduled cases received continuous SAPT starting seven days before the procedure. Emergency cases were treated with tirofiban followed by SAPT loading. The safety endpoint was ischemic complications occurring during the procedure and within four months of clinical follow-up.</p><p><strong>Results: </strong>The Pipeline Vantage or Flex Shield was used in 26 (63%) procedures, the FRED X in 12 (29%), the p48/64 Hydrophilic Polymer Coating in 2 (5%), and the Derivo Embolization Device 2heal in 1 (2%). Single antiplatelet therapy consisted of prasugrel in 27 (66%) patients, ticagrelor in 9 (22%), and ASA in 5 (12%). There were 2 (5%) early ischemic complications (one minor stroke and one transient ischemic attack). There were no late ischemic complications in the four-month follow-up of 35 patients. The six dropouts included four nontreatment-related deaths after subarachnoid hemorrhage and two patients with a poor outcome after subarachnoid hemorrhage. Complete and favorable occlusion rates (median: 7 months) were 75% (27/36) and 89% (32/36), respectively.</p><p><strong>Conclusions: </strong>Coated flow diverter implantation in the setting of SAPT was safe and effective and warrants confirmation in a prospective comparative trial.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199241286542"},"PeriodicalIF":1.5000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559911/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241286542","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This multicenter study evaluates the safety and efficacy of coated flow diverters (cFDs) for the treatment of cerebral aneurysms under single antiplatelet therapy (SAPT).
Methods: This is a retrospective, observational study of 41 patients (median age: 58 years) with 41 aneurysms (median size: 7 mm, 29 [71%] saccular, 9 [22%] ruptured) treated with cFDs at four neurovascular centers between 2020 and 2023. Scheduled cases received continuous SAPT starting seven days before the procedure. Emergency cases were treated with tirofiban followed by SAPT loading. The safety endpoint was ischemic complications occurring during the procedure and within four months of clinical follow-up.
Results: The Pipeline Vantage or Flex Shield was used in 26 (63%) procedures, the FRED X in 12 (29%), the p48/64 Hydrophilic Polymer Coating in 2 (5%), and the Derivo Embolization Device 2heal in 1 (2%). Single antiplatelet therapy consisted of prasugrel in 27 (66%) patients, ticagrelor in 9 (22%), and ASA in 5 (12%). There were 2 (5%) early ischemic complications (one minor stroke and one transient ischemic attack). There were no late ischemic complications in the four-month follow-up of 35 patients. The six dropouts included four nontreatment-related deaths after subarachnoid hemorrhage and two patients with a poor outcome after subarachnoid hemorrhage. Complete and favorable occlusion rates (median: 7 months) were 75% (27/36) and 89% (32/36), respectively.
Conclusions: Coated flow diverter implantation in the setting of SAPT was safe and effective and warrants confirmation in a prospective comparative trial.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...