Laparoscopic adrenalectomy performed with the Endo GIA™ Stapler as an easy and safe approach.

IF 1.8 4区 医学 Q2 SURGERY
Ohjoon Kwon, Kwang Y Paik
{"title":"Laparoscopic adrenalectomy performed with the Endo GIA™ Stapler as an easy and safe approach.","authors":"Ohjoon Kwon, Kwang Y Paik","doi":"10.23736/S2724-5691.24.10060-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this study was to determine whether the application of the Endo GIA<sup>™</sup> Stapler (Medtronic, Dublin, Ireland) could be helpful in the dissection of adrenal tumors in complicated cases.</p><p><strong>Methods: </strong>We retrospectively reviewed the records of patients who underwent laparoscopic adrenalectomy between 2012 and 2022 at the College of Medicine, Yeouido St. Mary's Hospital, The Catholic University of Korea (Seoul, Republic of Korea). We adopted the Endo GIA<sup>™</sup> Stapler (Medtronic) to seal vessels around adrenal gland and separate adrenal gland completely when it was difficult to perform meticulous dissection and isolation with laparoscopic instruments. Thirteen patients who underwent laparoscopic adrenalectomy with Endo GIA<sup>™</sup> staplers were reviewed and compared with 45 other patients who underwent laparoscopic adrenalectomy without Endo GIA<sup>™</sup> staplers.</p><p><strong>Results: </strong>There were no statistical differences between the two groups in demographic, tumor-related, and diagnostic variables. Surgical outcomes such as margin involvement, bleeding, operation duration, rate of conversion to open surgery, blood transfusion, complications, and recurrence were not different between the two groups.</p><p><strong>Conclusions: </strong>In our experience, applying of the Endo GIA<sup>™</sup> Stapler (Medtronic) in laparoscopic adrenalectomy is a feasible and acceptable approach.</p>","PeriodicalId":29847,"journal":{"name":"Minerva Surgery","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5691.24.10060-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The purpose of this study was to determine whether the application of the Endo GIA Stapler (Medtronic, Dublin, Ireland) could be helpful in the dissection of adrenal tumors in complicated cases.

Methods: We retrospectively reviewed the records of patients who underwent laparoscopic adrenalectomy between 2012 and 2022 at the College of Medicine, Yeouido St. Mary's Hospital, The Catholic University of Korea (Seoul, Republic of Korea). We adopted the Endo GIA Stapler (Medtronic) to seal vessels around adrenal gland and separate adrenal gland completely when it was difficult to perform meticulous dissection and isolation with laparoscopic instruments. Thirteen patients who underwent laparoscopic adrenalectomy with Endo GIA staplers were reviewed and compared with 45 other patients who underwent laparoscopic adrenalectomy without Endo GIA staplers.

Results: There were no statistical differences between the two groups in demographic, tumor-related, and diagnostic variables. Surgical outcomes such as margin involvement, bleeding, operation duration, rate of conversion to open surgery, blood transfusion, complications, and recurrence were not different between the two groups.

Conclusions: In our experience, applying of the Endo GIA Stapler (Medtronic) in laparoscopic adrenalectomy is a feasible and acceptable approach.

使用 Endo GIA™ 缝合器进行腹腔镜肾上腺切除术是一种简单安全的方法。
背景:本研究旨在确定 Endo GIA™ Stapler(美敦力,爱尔兰都柏林)的应用是否有助于复杂病例中肾上腺肿瘤的解剖:我们回顾性地查看了 2012 年至 2022 年期间在韩国天主教大学医学院、汝矣岛圣玛丽医院(大韩民国首尔)接受腹腔镜肾上腺切除术的患者记录。我们采用了 Endo GIA™ Stapler(美敦力)来封闭肾上腺周围的血管,并在腹腔镜器械难以进行细致解剖和分离的情况下将肾上腺完全分离。对使用 Endo GIA™ 订书机进行腹腔镜肾上腺切除术的 13 例患者进行了回顾,并与未使用 Endo GIA™ 订书机进行腹腔镜肾上腺切除术的另外 45 例患者进行了比较:结果:两组患者在人口统计学、肿瘤相关变量和诊断变量方面没有统计学差异。手术结果,如边缘受累、出血、手术时间、转为开放手术的比例、输血、并发症和复发在两组之间没有差异:根据我们的经验,在腹腔镜肾上腺切除术中应用 Endo GIA™ 缝合器(美敦力)是一种可行且可接受的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Minerva Surgery
Minerva Surgery SURGERY-
CiteScore
1.90
自引率
7.10%
发文量
320
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信