Magnetic navigation-assisted colonoscopic enteral tube placement in swine (with video): a preliminary study.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Lin-Biao Xiang, Chen-Xi Yang, Jia-Wei Yu, Xian-Jie Bai, Zhi-Jie Zhang, Yu-Xuan Liuyang, Zhi-Ren Chen, Yu-Chen Mei, Jia-Tong Zhao, Lu Ren, Feng-Gang Ren, Gang-Hua Yang, Ying-Min Yao, Xu-Feng Zhang, Yi Lyu, Qiang Lu
{"title":"Magnetic navigation-assisted colonoscopic enteral tube placement in swine (with video): a preliminary study.","authors":"Lin-Biao Xiang, Chen-Xi Yang, Jia-Wei Yu, Xian-Jie Bai, Zhi-Jie Zhang, Yu-Xuan Liuyang, Zhi-Ren Chen, Yu-Chen Mei, Jia-Tong Zhao, Lu Ren, Feng-Gang Ren, Gang-Hua Yang, Ying-Min Yao, Xu-Feng Zhang, Yi Lyu, Qiang Lu","doi":"10.1186/s12876-024-03440-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Colonoscopic enteral tube placement using current methods has some shortcomings, such as the complexity of the procedure and tube dislodgement. The magnetic navigation technique (MNT) has been proven effective for nasoenteral feeding tube placement, and is associated with reduced cost and time to initiation of nutrition. This study attempted to develop a novel method for enteral tube placement using MNT.</p><p><strong>Methods: </strong>The MNT device consisted of an external magnet and a 12 Fr tube with a magnet at the end. Ten swine were used, and bowel cleansing was routinely performed before colonoscopy. Intravenous anesthesia with propofol and ketamine was administered. A colonoscopic enteral tube was placed using the MNT. The position of the end of the enteral tube was determined by radiography, and angiography was performed to check for colonic perforations. Colonoscopy was used to detect intestinal mucosal damage after tube removal.</p><p><strong>Results: </strong>MNT-assisted colonoscopic enteral tube placement was successfully completed in all pigs. The median operating time was 30 (26-47) min. No colon perforation was detected on colonography after enteral tube placement, and no colonic mucosal bleeding or injury was detected after the removal of the enteral tube.</p><p><strong>Conclusions: </strong>MNT-assisted colonoscopic enteral tube placement is feasible and safe in swine and may represent a valuable method for microbial therapy, colonic drainage, and host-microbiota interaction research in the future.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"24 1","pages":"341"},"PeriodicalIF":4.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443754/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12876-024-03440-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Colonoscopic enteral tube placement using current methods has some shortcomings, such as the complexity of the procedure and tube dislodgement. The magnetic navigation technique (MNT) has been proven effective for nasoenteral feeding tube placement, and is associated with reduced cost and time to initiation of nutrition. This study attempted to develop a novel method for enteral tube placement using MNT.

Methods: The MNT device consisted of an external magnet and a 12 Fr tube with a magnet at the end. Ten swine were used, and bowel cleansing was routinely performed before colonoscopy. Intravenous anesthesia with propofol and ketamine was administered. A colonoscopic enteral tube was placed using the MNT. The position of the end of the enteral tube was determined by radiography, and angiography was performed to check for colonic perforations. Colonoscopy was used to detect intestinal mucosal damage after tube removal.

Results: MNT-assisted colonoscopic enteral tube placement was successfully completed in all pigs. The median operating time was 30 (26-47) min. No colon perforation was detected on colonography after enteral tube placement, and no colonic mucosal bleeding or injury was detected after the removal of the enteral tube.

Conclusions: MNT-assisted colonoscopic enteral tube placement is feasible and safe in swine and may represent a valuable method for microbial therapy, colonic drainage, and host-microbiota interaction research in the future.

磁导航辅助结肠镜肠管置入猪体内(附视频):初步研究。
背景:目前使用的结肠镜肠管置入方法存在一些缺点,如手术复杂和肠管脱落。磁导航技术(MNT)已被证明对鼻肠管置管有效,并能降低成本和缩短开始营养的时间。本研究试图开发一种使用磁导航技术置入肠管的新方法:MNT 装置由外部磁铁和末端带有磁铁的 12 Fr 管组成。使用了 10 头猪,在结肠镜检查前常规进行肠道清洁。使用异丙酚和氯胺酮进行静脉麻醉。使用 MNT 放置结肠镜肠管。肠管末端的位置由射线照相确定,并进行血管造影检查结肠穿孔。结肠镜检查用于检测拔管后的肠粘膜损伤:结果:所有猪均成功完成了 MNT 辅助结肠镜肠管置入术。中位手术时间为 30 (26-47) 分钟。放置肠管后结肠造影未发现结肠穿孔,拔出肠管后也未发现结肠粘膜出血或损伤:结论:MNT 辅助结肠镜肠管置入术在猪身上是可行且安全的,可能是未来微生物治疗、结肠引流和宿主微生物群相互作用研究的一种有价值的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信