Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study.

IF 0.5 Q4 OPHTHALMOLOGY
Journal of VitreoRetinal Diseases Pub Date : 2024-07-28 eCollection Date: 2024-09-01 DOI:10.1177/24741264241263172
Yavuz Cakir, Antoine Sassine, Karen Matar, Reem Amine, Jamie Reese, Sunil K Srivastava, Justis P Ehlers
{"title":"Assessment of Macular Hole Closure Speed Using Trans-tamponade OCT and 3-Dimensional Macular Hole Segmentation in the DISCOVER Study.","authors":"Yavuz Cakir, Antoine Sassine, Karen Matar, Reem Amine, Jamie Reese, Sunil K Srivastava, Justis P Ehlers","doi":"10.1177/24741264241263172","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. <b>Methods</b>: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preoperative spectral-domain OCT (SD-OCT) and postoperative day 1 (POD1) trans-tamponade OCT were analyzed. Preoperative SD-OCT macular cubes were imported and analyzed using a machine learning-enhanced segmentation platform. Nine preoperative segmentation parameters were analyzed (maximum foveal height, apex area, base area, central foveal area, maximum apex diameter, maximum base diameter, maximum depth, minimum foveal width, volume). In addition, 2 new metrics-the macular hole index and tractional hole index-were calculated. POD1 trans-tamponade OCTs were obtained and evaluated for hole closure. <b>Results</b>: Of the 66 eyes with an FTMH, 16 (24%) had a chronic MH and 5 (8%) were reoperations from FTMH nonclosure after previous surgery. Nine eyes (14%) had an open MH on POD1 trans-tamponade OCT (6 chronic MHs [66%]; 2 reoperations [22%]); the remaining 57 MHs (86%) were closed. Multiple segmentation parameters were significantly associated with POD1 closure. <b>Conclusions</b>: Volumetric MH measurements and trans-tamponade POD1 OCT closure status are important in predicting MH closure speed and the need for postoperative positioning. Individualized positioning duration in MH could lower perioperative morbidity and vastly enhance quality of life.</p>","PeriodicalId":17919,"journal":{"name":"Journal of VitreoRetinal Diseases","volume":"8 5","pages":"558-564"},"PeriodicalIF":0.5000,"publicationDate":"2024-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11418717/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of VitreoRetinal Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/24741264241263172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: To explore opportunities for individualized postoperative positioning duration in macular hole (MH) surgery. Methods: This post hoc analysis comprised eyes that had full-thickness MH (FTMH) repair in the prospective DISCOVER intraoperative optical coherence tomography (OCT) study. Preoperative spectral-domain OCT (SD-OCT) and postoperative day 1 (POD1) trans-tamponade OCT were analyzed. Preoperative SD-OCT macular cubes were imported and analyzed using a machine learning-enhanced segmentation platform. Nine preoperative segmentation parameters were analyzed (maximum foveal height, apex area, base area, central foveal area, maximum apex diameter, maximum base diameter, maximum depth, minimum foveal width, volume). In addition, 2 new metrics-the macular hole index and tractional hole index-were calculated. POD1 trans-tamponade OCTs were obtained and evaluated for hole closure. Results: Of the 66 eyes with an FTMH, 16 (24%) had a chronic MH and 5 (8%) were reoperations from FTMH nonclosure after previous surgery. Nine eyes (14%) had an open MH on POD1 trans-tamponade OCT (6 chronic MHs [66%]; 2 reoperations [22%]); the remaining 57 MHs (86%) were closed. Multiple segmentation parameters were significantly associated with POD1 closure. Conclusions: Volumetric MH measurements and trans-tamponade POD1 OCT closure status are important in predicting MH closure speed and the need for postoperative positioning. Individualized positioning duration in MH could lower perioperative morbidity and vastly enhance quality of life.

在 DISCOVER 研究中使用经填塞 OCT 和三维黄斑孔分割评估黄斑孔闭合速度。
简介探讨黄斑孔(MH)手术术后定位时间个体化的机会。方法:这项事后分析包括在前瞻性 DISCOVER 术中光学相干断层扫描(OCT)研究中进行全厚黄斑孔(FTMH)修复的眼睛。对术前光谱域 OCT(SD-OCT)和术后第 1 天(POD1)经填塞 OCT 进行了分析。导入术前 SD-OCT 黄斑立方体,并使用机器学习增强型分割平台进行分析。分析了九个术前分割参数(最大眼窝高度、顶点面积、基底面积、中心眼窝面积、最大顶点直径、最大基底直径、最大深度、最小眼窝宽度、体积)。此外,还计算了两个新指标--黄斑孔指数和牵引孔指数。获得 POD1 经填塞 OCT 图像并评估孔闭合情况。结果:在 66 只患有 FTMH 的眼球中,16 只(24%)患有慢性 MH,5 只(8%)是因之前手术后 FTMH 未闭合而再次手术。有 9 只眼睛(14%)在 POD1 经填塞 OCT 上有开放的 MH(6 只慢性 MH [66%];2 只再次手术 [22%]);其余 57 只 MH(86%)是闭合的。多个分段参数与 POD1 闭合显著相关。结论:MH容积测量和经填塞POD1 OCT闭合状态对预测MH闭合速度和术后定位需求非常重要。个性化的 MH 定位持续时间可以降低围手术期的发病率,并大大提高生活质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
16.70%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信