{"title":"Three-Dimensional Variable Slab-Selective Projection Acquisition Imaging.","authors":"Jinil Park, Taehoon Shin, Jang-Yeon Park","doi":"10.1109/TMI.2024.3460974","DOIUrl":null,"url":null,"abstract":"<p><p>Three-dimensional (3D) projection acquisition (PA) imaging has recently gained attention because of its advantages, such as achievability of very short echo time, less sensitivity to motion, and undersampled acquisition of projections without sacrificing spatial resolution. However, larger subjects require a stronger Nyquist criterion and are more likely to be affected by outer-volume signals outside the field of view (FOV), which significantly degrades the image quality. Here, we proposed a variable slab-selective projection acquisition (VSS-PA) method to mitigate the Nyquist criterion and effectively suppress aliasing streak artifacts in 3D PA imaging. The proposed method involves maintaining the vertical orientation of the slab-selective gradient for frequency-selective spin excitation and the readout gradient for data acquisition. As VSS-PA can selectively excite spins only in the width of the desired FOV in the projection direction during data acquisition, the effective size of the scanned object that determines the Nyquist criterion can be reduced. Additionally, unwanted signals originating from outside the FOV (e.g., aliasing streak artifacts) can be effectively avoided. The mitigation of the Nyquist criterion owing to VSS-PA was theoretically described and confirmed through numerical simulations and phantom and human lung experiments. These experiments further showed that the aliasing streak artifacts were nearly suppressed.</p>","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"PP ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TMI.2024.3460974","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Three-dimensional (3D) projection acquisition (PA) imaging has recently gained attention because of its advantages, such as achievability of very short echo time, less sensitivity to motion, and undersampled acquisition of projections without sacrificing spatial resolution. However, larger subjects require a stronger Nyquist criterion and are more likely to be affected by outer-volume signals outside the field of view (FOV), which significantly degrades the image quality. Here, we proposed a variable slab-selective projection acquisition (VSS-PA) method to mitigate the Nyquist criterion and effectively suppress aliasing streak artifacts in 3D PA imaging. The proposed method involves maintaining the vertical orientation of the slab-selective gradient for frequency-selective spin excitation and the readout gradient for data acquisition. As VSS-PA can selectively excite spins only in the width of the desired FOV in the projection direction during data acquisition, the effective size of the scanned object that determines the Nyquist criterion can be reduced. Additionally, unwanted signals originating from outside the FOV (e.g., aliasing streak artifacts) can be effectively avoided. The mitigation of the Nyquist criterion owing to VSS-PA was theoretically described and confirmed through numerical simulations and phantom and human lung experiments. These experiments further showed that the aliasing streak artifacts were nearly suppressed.