Nicole Valle, Mathew Suji Eapen, Krishna Pillai, Richard Morris, Javed Akhter, Ahmed H Mekkawy, David L Morris, Sarah J Valle
{"title":"Impact of Nebulized BromAc<sup>®</sup> on Mucus Plug Clearance in a Mechanically Ventilated Ex Vivo Ovine Lung Model of Obstructive Respiratory Conditions.","authors":"Nicole Valle, Mathew Suji Eapen, Krishna Pillai, Richard Morris, Javed Akhter, Ahmed H Mekkawy, David L Morris, Sarah J Valle","doi":"10.3390/life14091111","DOIUrl":null,"url":null,"abstract":"<p><p>Mucus plugging of the respiratory tract occurs in airway diseases, including asthma, chronic obstructive pulmonary disease, and cystic fibrosis. It can cause blockage of the airways, leading to breathlessness and lung failure. Here, we used a ventilatory setup to demonstrate the effect of BromAc<sup>®</sup> in dissolving mucus plugs in a novel ex vivo ovine obstructive lung model. Mucus simulant was filled into the trachea of freshly slaughtered ovine lungs and ventilated via an endotracheal tube (ETT) using Continuous Mandatory Ventilation. Predetermined single or repeated doses of Bromelain, Acetylcysteine (Ac), BromAc<sup>®</sup>, and saline control were administered via an Aerogen<sup>®</sup> vibrating nebulizer and ventilated for 30 or 60 min. Ventilatory recording of resistance, compliance, and tidal volume was conducted, and rheology pre- and post-treatment were measured. A significant decline in airway resistance (<i>p</i> < 0.0001) compared to the saline control was observed when treated with Bromelain, Ac, and BromAc<sup>®</sup>, with the latter showing a stronger mucolytic effect than single agents. The decline in resistance was also effective in shorter time points (<i>p</i> < 0.05) at lower doses of the drugs. Changes in compliance, peak pressure, and tidal volume were not observed after administration of the drugs. Rheology measurements revealed that BromAc<sup>®</sup><sup>TM</sup> significantly reduced the viscosity of the mucin at the end of 30 min and 60 min time points (<i>p</i> < 0.001) compared to the saline control. BromAc<sup>®</sup> showed complete dissolution of the respiratory mucus simulant and improved ventilatory airflow parameters in the ex vivo ovine model.</p>","PeriodicalId":56144,"journal":{"name":"Life-Basel","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11433166/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Life-Basel","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3390/life14091111","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Mucus plugging of the respiratory tract occurs in airway diseases, including asthma, chronic obstructive pulmonary disease, and cystic fibrosis. It can cause blockage of the airways, leading to breathlessness and lung failure. Here, we used a ventilatory setup to demonstrate the effect of BromAc® in dissolving mucus plugs in a novel ex vivo ovine obstructive lung model. Mucus simulant was filled into the trachea of freshly slaughtered ovine lungs and ventilated via an endotracheal tube (ETT) using Continuous Mandatory Ventilation. Predetermined single or repeated doses of Bromelain, Acetylcysteine (Ac), BromAc®, and saline control were administered via an Aerogen® vibrating nebulizer and ventilated for 30 or 60 min. Ventilatory recording of resistance, compliance, and tidal volume was conducted, and rheology pre- and post-treatment were measured. A significant decline in airway resistance (p < 0.0001) compared to the saline control was observed when treated with Bromelain, Ac, and BromAc®, with the latter showing a stronger mucolytic effect than single agents. The decline in resistance was also effective in shorter time points (p < 0.05) at lower doses of the drugs. Changes in compliance, peak pressure, and tidal volume were not observed after administration of the drugs. Rheology measurements revealed that BromAc®TM significantly reduced the viscosity of the mucin at the end of 30 min and 60 min time points (p < 0.001) compared to the saline control. BromAc® showed complete dissolution of the respiratory mucus simulant and improved ventilatory airflow parameters in the ex vivo ovine model.
Life-BaselBiochemistry, Genetics and Molecular Biology-General Biochemistry,Genetics and Molecular Biology
CiteScore
4.30
自引率
6.20%
发文量
1798
审稿时长
11 weeks
期刊介绍:
Life (ISSN 2075-1729) is an international, peer-reviewed open access journal of scientific studies related to fundamental themes in Life Sciences, especially those concerned with the origins of life and evolution of biosystems. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers.