Superior Electrochemical Sensor Application of Co3O4/C Heterostructure in Rapid Analysis of Anticancer Drug Palbociclib in Pharmaceutical Formulations and Biological Fluids

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Ozgul Vural, Nesrin Buğday, Asena Ayşe Genc, Nevin Erk, Ozgur Duygulu, Sedat Yaşar
{"title":"Superior Electrochemical Sensor Application of Co3O4/C Heterostructure in Rapid Analysis of Anticancer Drug Palbociclib in Pharmaceutical Formulations and Biological Fluids","authors":"Ozgul Vural, Nesrin Buğday, Asena Ayşe Genc, Nevin Erk, Ozgur Duygulu, Sedat Yaşar","doi":"10.1021/acs.langmuir.4c02551","DOIUrl":null,"url":null,"abstract":"In this work, we report a study examining how different salt concentrations affect the structure and electrochemical performance of two Co<sub>3</sub>O<sub>4</sub>/C materials designed for the fabrication of an easy, cheap, fast, safe, and useful electrochemical sensor for the detection of Palbociclib (PLB). Co<sub>3</sub>O<sub>4</sub> nanoparticles were successfully created by encapsulating them in N-doped amorphous carbon matrices by using the molten salt-assisted approach. In this process, different amounts of potassium iodate and zeolitic imidazolate framework-12 (ZIF-12) were used, followed by pyrolysis at 800 °C. Optimum Co<sub>3</sub>O<sub>4</sub> embedded porous carbon structures were obtained, and the composite with the highest electrochemical properties was modified to a glassy carbon electrode (GCE) surface for PLB detection. The linear response spanned from 1.0 to 5.0 μM, featuring a limit of detection (LOD) of 0.122 μM and a limit of quantification (LOQ) of 0.408 μM; the correlation coefficient was calculated as 0.995. The high sensitivity of the method in detecting PLB in pharmaceutical samples and human urine demonstrated its feasibility, with recovery percentages ranging from 99.3% to 101.3% and relative standard deviation (RSD) values of &lt;3%. Therefore, this technique will make a significant contribution to monitoring and improving existing cancer treatment options.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.langmuir.4c02551","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, we report a study examining how different salt concentrations affect the structure and electrochemical performance of two Co3O4/C materials designed for the fabrication of an easy, cheap, fast, safe, and useful electrochemical sensor for the detection of Palbociclib (PLB). Co3O4 nanoparticles were successfully created by encapsulating them in N-doped amorphous carbon matrices by using the molten salt-assisted approach. In this process, different amounts of potassium iodate and zeolitic imidazolate framework-12 (ZIF-12) were used, followed by pyrolysis at 800 °C. Optimum Co3O4 embedded porous carbon structures were obtained, and the composite with the highest electrochemical properties was modified to a glassy carbon electrode (GCE) surface for PLB detection. The linear response spanned from 1.0 to 5.0 μM, featuring a limit of detection (LOD) of 0.122 μM and a limit of quantification (LOQ) of 0.408 μM; the correlation coefficient was calculated as 0.995. The high sensitivity of the method in detecting PLB in pharmaceutical samples and human urine demonstrated its feasibility, with recovery percentages ranging from 99.3% to 101.3% and relative standard deviation (RSD) values of <3%. Therefore, this technique will make a significant contribution to monitoring and improving existing cancer treatment options.

Abstract Image

将 Co3O4/C 异质结构应用于快速分析药物制剂和生物液体中的抗癌药物帕博西尼(Palbociclib)的卓越电化学传感器
在这项工作中,我们报告了一项研究,该研究探讨了不同盐浓度如何影响两种 Co3O4/C 材料的结构和电化学性能,这两种材料设计用于制造一种简便、廉价、快速、安全且有用的电化学传感器,以检测 Palbociclib (PLB)。通过使用熔盐辅助方法将 Co3O4 纳米粒子封装在掺杂 N 的无定形碳基质中,成功地制造出了 Co3O4 纳米粒子。在此过程中,使用了不同量的碘酸钾和沸石咪唑酸盐框架-12(ZIF-12),然后在 800 °C 下进行热解。获得了最佳的 Co3O4 嵌入多孔碳结构,并将电化学性能最高的复合材料修饰到玻璃碳电极(GCE)表面,用于检测 PLB。该方法的线性范围为1.0~5.0 μM,检出限为0.122 μM,定量限为0.408 μM,相关系数为0.995。该方法的回收率为99.3%~101.3%,相对标准偏差(RSD)为3%。因此,这项技术将为监测和改进现有的癌症治疗方案做出重大贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信