Kairos positive airway pressure (KPAP) equals continuous PAP in effectiveness, and offers superior comfort for obstructive sleep apnea treatment

IF 3.8 2区 医学 Q1 CLINICAL NEUROLOGY
{"title":"Kairos positive airway pressure (KPAP) equals continuous PAP in effectiveness, and offers superior comfort for obstructive sleep apnea treatment","authors":"","doi":"10.1016/j.sleep.2024.09.028","DOIUrl":null,"url":null,"abstract":"<div><h3>Study objectives</h3><div>A recent study challenged the prevailing clinical view that maintaining inspiratory positive airway pressure (IPAP) is necessary for upper airway patency, demonstrating no differences in apnea hypopnea index (AHI) between continuous PAP (CPAP) with and without a resistor to reduce IPAP. In this study, we assessed the effect of Kairos PAP (KPAP), a new algorithm which features multiple drops in IPAP, only returning to therapeutic pressure near the end expiration, on sleep apnea severity and subjective comfort.</div></div><div><h3>Methods</h3><div>Two randomized clinical trials were conducted. In the <em>Efficacy</em> trial, the effect of KPAP vs. CPAP on AHI in PAP-treated OSA patients was examined using a split-night design, adjusting for period, sequence and fraction of supine sleep (mixed models). Unintentional leak differences between treatments were also examined. Exploratory analyses assessed the effect of KPAP vs. CPAP on key polysomnography outcomes. In the <em>Comfort</em> trial, we tested subjective preference for KPAP vs. CPAP at 9 and 13 cmH<sub>2</sub>O in PAP-naïve OSA patients.</div></div><div><h3>Results</h3><div>In the <em>Efficacy</em> trial (N = 48), KPAP reduced AHI more than CPAP (mean difference [95%CI]: −0.5 [−0.8, −0.2] events/h, P = 0.007). Unintentional leak was also reduced by over 50 % (−2.5 [−3.2, −1.7] L/min, P &lt; 0.001). No significant change was observed in the exploratory variables assessed. In the <em>Comfort</em> trial (N = 150), 69 [61, 77] % and 84 [77, 89] % of participants preferred KPAP over CPAP at 9 and 13 cmH<sub>2</sub>O, respectively (P &lt; 0.001).</div></div><div><h3>Conclusions</h3><div>KPAP is as effective as CPAP in reducing respiratory events, but is more comfortable and potentially better tolerated.</div></div>","PeriodicalId":21874,"journal":{"name":"Sleep medicine","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sleep medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1389945724004490","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Study objectives

A recent study challenged the prevailing clinical view that maintaining inspiratory positive airway pressure (IPAP) is necessary for upper airway patency, demonstrating no differences in apnea hypopnea index (AHI) between continuous PAP (CPAP) with and without a resistor to reduce IPAP. In this study, we assessed the effect of Kairos PAP (KPAP), a new algorithm which features multiple drops in IPAP, only returning to therapeutic pressure near the end expiration, on sleep apnea severity and subjective comfort.

Methods

Two randomized clinical trials were conducted. In the Efficacy trial, the effect of KPAP vs. CPAP on AHI in PAP-treated OSA patients was examined using a split-night design, adjusting for period, sequence and fraction of supine sleep (mixed models). Unintentional leak differences between treatments were also examined. Exploratory analyses assessed the effect of KPAP vs. CPAP on key polysomnography outcomes. In the Comfort trial, we tested subjective preference for KPAP vs. CPAP at 9 and 13 cmH2O in PAP-naïve OSA patients.

Results

In the Efficacy trial (N = 48), KPAP reduced AHI more than CPAP (mean difference [95%CI]: −0.5 [−0.8, −0.2] events/h, P = 0.007). Unintentional leak was also reduced by over 50 % (−2.5 [−3.2, −1.7] L/min, P < 0.001). No significant change was observed in the exploratory variables assessed. In the Comfort trial (N = 150), 69 [61, 77] % and 84 [77, 89] % of participants preferred KPAP over CPAP at 9 and 13 cmH2O, respectively (P < 0.001).

Conclusions

KPAP is as effective as CPAP in reducing respiratory events, but is more comfortable and potentially better tolerated.
凯罗斯气道正压(KPAP)的效果与持续气道正压相同,为阻塞性睡眠呼吸暂停的治疗提供卓越的舒适性
研究目的最近的一项研究对维持吸气气道正压 (IPAP) 是上气道通畅所必需的这一普遍临床观点提出了质疑,研究结果表明,在使用和不使用电阻器降低 IPAP 的连续气道正压 (CPAP) 之间,呼吸暂停低通气指数 (AHI) 没有差异。在本研究中,我们评估了 Kairos PAP (KPAP) 对睡眠呼吸暂停严重程度和主观舒适度的影响。在 "疗效 "试验中,采用分夜设计考察了 KPAP 与 CPAP 对经 PAP 治疗的 OSA 患者 AHI 的影响,并对仰卧睡眠的时间、顺序和比例进行了调整(混合模型)。此外,还研究了不同治疗方法之间的无意泄漏差异。探索性分析评估了 KPAP 与 CPAP 对主要多导睡眠图结果的影响。在舒适度试验中,我们测试了 PAP 不适用的 OSA 患者对 KPAP 与 CPAP 在 9 和 13 cmH2O 条件下的主观偏好。无意泄漏也减少了 50% 以上(-2.5 [-3.2, -1.7] L/min,P = 0.001)。在所评估的探索性变量中未观察到明显变化。在舒适度试验(N = 150)中,分别有 69 [61, 77] % 和 84 [77, 89] % 的参与者更喜欢 KPAP 而不是 9 和 13 cmH2O 的 CPAP(P < 0.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sleep medicine
Sleep medicine 医学-临床神经学
CiteScore
8.40
自引率
6.20%
发文量
1060
审稿时长
49 days
期刊介绍: Sleep Medicine aims to be a journal no one involved in clinical sleep medicine can do without. A journal primarily focussing on the human aspects of sleep, integrating the various disciplines that are involved in sleep medicine: neurology, clinical neurophysiology, internal medicine (particularly pulmonology and cardiology), psychology, psychiatry, sleep technology, pediatrics, neurosurgery, otorhinolaryngology, and dentistry. The journal publishes the following types of articles: Reviews (also intended as a way to bridge the gap between basic sleep research and clinical relevance); Original Research Articles; Full-length articles; Brief communications; Controversies; Case reports; Letters to the Editor; Journal search and commentaries; Book reviews; Meeting announcements; Listing of relevant organisations plus web sites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信