Nithya Boopathiraj, Isabella V Wagner, Paul Connor Lentz, Christian Draper, Chelsey Krambeer, Yazan S Abubaker, Bryan Chin Hou Ang, Darby D Miller, Syril Dorairaj
{"title":"36-Month Outcomes of Standalone Kahook Dual Blade Goniotomy Compared with Ab-Interno Closed Conjunctiva Xen Gel Stent Implantation.","authors":"Nithya Boopathiraj, Isabella V Wagner, Paul Connor Lentz, Christian Draper, Chelsey Krambeer, Yazan S Abubaker, Bryan Chin Hou Ang, Darby D Miller, Syril Dorairaj","doi":"10.2147/OPTH.S473303","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the safety and effectiveness of standalone Kahook Dual Blade (KDB) excisional goniotomy to standalone ab-interno Xen gel stent implantation in eyes with moderate-to-severe open-angle glaucoma (OAG).</p><p><strong>Methods: </strong>A single-center, retrospective study including eyes with moderate-to-severe OAG undergoing standalone KDB goniotomy or Xen gel stent implantation was conducted. Intraocular pressure (IOP), the number of antiglaucoma medications taken daily, and best-corrected visual acuity (BCVA) were recorded at baseline and for up to 36-months. Primary outcomes assessed included changes from baseline in IOP and the number of antiglaucoma medications taken. Intergroup comparisons were conducted using independent-samples Student's <i>t</i>-tests. The incidence of intraoperative and postoperative adverse events and the need for glaucoma surgical re-interventions were also recorded.</p><p><strong>Results: </strong>Eyes receiving standalone KDB (n=26) or Xen gel stent (n=45) surgery were analyzed. The baseline mean IOP and number of antiglaucoma medications in both groups were as follows: KDB: 23.2 ± 6.0 mmHg, 2.2 ± 1.4 medications; Xen: 22.7 ± 8.8 mmHg, 3.0 ± 1.0 medications. At 36 months, IOP was reduced to 16.6 ± 5.4 mmHg in KDB eyes (n=23, -23.5%; p=0.0004) and 15.3 ± 5.6 mmHg in Xen gel stent eyes (n=15, -22.1%; p=0.006), while number of antiglaucoma medications was reduced to 1.1 ± 0.7 (-30.8%; p=0.0005) and 2.2 ± 1.4 (-25.6%; p=0.01), respectively. Three eyes (11.5%) in the KDB group and 19 eyes (42.2%) in the Xen gel stent group required additional surgery before month 36 due to refractory high IOP.</p><p><strong>Conclusion: </strong>Both KDB goniotomy and Xen gel stent implantation significantly lowered the IOP and antiglaucoma medication burden in patients with moderate-to-severe OAG. While the Xen gel stent is frequently used to treat moderate-to-severe OAG patients with uncontrolled IOP, standalone KDB goniotomy may be equally effective as a long-term intervention, reducing the need for subsequent glaucoma surgery.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414631/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S473303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To compare the safety and effectiveness of standalone Kahook Dual Blade (KDB) excisional goniotomy to standalone ab-interno Xen gel stent implantation in eyes with moderate-to-severe open-angle glaucoma (OAG).
Methods: A single-center, retrospective study including eyes with moderate-to-severe OAG undergoing standalone KDB goniotomy or Xen gel stent implantation was conducted. Intraocular pressure (IOP), the number of antiglaucoma medications taken daily, and best-corrected visual acuity (BCVA) were recorded at baseline and for up to 36-months. Primary outcomes assessed included changes from baseline in IOP and the number of antiglaucoma medications taken. Intergroup comparisons were conducted using independent-samples Student's t-tests. The incidence of intraoperative and postoperative adverse events and the need for glaucoma surgical re-interventions were also recorded.
Results: Eyes receiving standalone KDB (n=26) or Xen gel stent (n=45) surgery were analyzed. The baseline mean IOP and number of antiglaucoma medications in both groups were as follows: KDB: 23.2 ± 6.0 mmHg, 2.2 ± 1.4 medications; Xen: 22.7 ± 8.8 mmHg, 3.0 ± 1.0 medications. At 36 months, IOP was reduced to 16.6 ± 5.4 mmHg in KDB eyes (n=23, -23.5%; p=0.0004) and 15.3 ± 5.6 mmHg in Xen gel stent eyes (n=15, -22.1%; p=0.006), while number of antiglaucoma medications was reduced to 1.1 ± 0.7 (-30.8%; p=0.0005) and 2.2 ± 1.4 (-25.6%; p=0.01), respectively. Three eyes (11.5%) in the KDB group and 19 eyes (42.2%) in the Xen gel stent group required additional surgery before month 36 due to refractory high IOP.
Conclusion: Both KDB goniotomy and Xen gel stent implantation significantly lowered the IOP and antiglaucoma medication burden in patients with moderate-to-severe OAG. While the Xen gel stent is frequently used to treat moderate-to-severe OAG patients with uncontrolled IOP, standalone KDB goniotomy may be equally effective as a long-term intervention, reducing the need for subsequent glaucoma surgery.